hit counter script

T093: Automatic Cleaning Failure; T094: Drive Bay Open; T095: Installation And Verification Test (Ivt) Failure - IBM TS3310 Maintenance Information

System storage tape library
Hide thumbs Also See for TS3310:
Table of Contents

Advertisement

T093: Automatic Cleaning Failure

Description
Detection Scenario
Root Cause
Resolution

T094: Drive Bay Open

Description
Detection Scenario
Root Causes
Possible CRU
Resolution

T095: Installation and Verification Test (IVT) Failure

Description
6-44
TS3310 Tape Library Maintenance Information
GUI Description: The library detected a problem during an automatic
cleaning operation.
Explanation: When the library is set up for Auto Clean, all the normal tickets
for cleaning issues are disabled, since the auto clean mechanism will resolve
any of these RAS tickets automatically. There is, however, one case where a
ticket needs to be posted: If the auto clean mechanism itself fails. This is the
only ticket that will be produced.
Auto Clean mechanism fails.
1. Auto Clean setup error (such as a user manually removing a cleaning
cartridge)
2. Any tape, motion, or driver error for which there already exists a RAS
ticket
Perform "DR081: Resolve Autoclean Failure" on page 6-84.
GUI Description: A library drive bay in the rear of the library is open.
Explanation: At boot time or run time the library detects that at least one of
the unoccupied drive bays does not have a cover on it. For safety reasons, if
a drive bay is not occupied by a drive and does not have a cover plate
installed, the robot is slowed to half speed to minimize the risk of someone
putting their hand inside the library and having the robot run into it at full
speed. Library operations will take twice as long in this state. As users
normally remove the drive bay covers to insert or move drives, this library
will wait between 30 seconds and 10 minutes after detecting this condition to
post the operator intervention message. The library does not have the
capability of displaying the location of the open drive bay.
v Missing drive cover plate
v Drive cover is loose or ajar and not electrically connected
v User removed the panel and forgot to put it back.
v Cover plate was not put on securely and the electrical connection is not
solid.
v The cover plate is damaged in such a way that the electrical connection
cannot be made.
v Drive pulled back.
Drive cover plate.
Perform "DR054: Resolve Open Drive Bay" on page 6-80.
GUI Description: A sub-test failed during the Installation & Verification Test.
Explanation: The library contains a verification test that can be run to
validate that the system has been installed properly and is up and running.
Errors can occur during this test. The library will post this ticket whenever
an error occurs during this Installation & Verification Test that does not affect
the overall functionality of the library. It is more of a warning that a problem
may be developing.