Ex.2 When there are 3 effective digits (such as in high precision metal film resistors). 562 x 10 5621 RN1/4PC CONTRAST TABLE BDP-160-K/YXE8, BDP-170/SXE, BDP-170/PWXE and BDP-80FD/CUXE are constructed the same except for the following: Mark Symbol and Description BDP-160-K/YXE8 BDP-170/SXE...
Page 3
Note: This list is not complete. Only components that are available as service part are listed! F SWITCH BOARD ASSY Although 08-BDP160-SB0 and 08-BDP170-SB0 are different and are NOT COMPATIBLE! Some components on these assy's are different. Since these different components are not available as service part, they are not listed. BDP-170...
Mainly for Production Line, but some items can be used in Service. Please see "SP Mode" for details. [8] PDXY Check Verifies misalignment of optical axis. Refer to "PDXY Check" for details. [9] Error Rate Test Determine the error rate of the disc. Refer to "Error Rate Test" for details. BDP-170...
Page 6
The following is to explain items usable in Service. Other items require time for completion, or are not suited for Service purposes. If you select them by mistake, press the [STOP] button to end that item you accidentally selected. (none of the items will affect the main unit) BDP-170...
Page 7
If an NG is generated in a specific disc only, the defect is likely to be caused by the disc. If an NG is generated in other discs too, the defect is likely to be caused by the drive part. However, even if Pass is displayed after this test, it is difficult to determine that the Driver is normal with these Pass judgments only. BDP-170...
Page 8
TOC read time-out criterion over PIPO_TIMEOUT_ERROR Time-out criterion over PIPO_C1C2_ERROR Read PIPO command failed PIPO_C1C2_OVER PIPO criterion over RD_CMD_FAIL_ERROR Read command failed RD_CMD_ERROR Command error or illegality mode RD_TIME_OUT_ERROR Read command time-out criterion over CHECK_FA_TABLE_ERROR FA table check-sum error BDP-170...
Page 9
If the measurement value is very close to 40% even if an NG is not generated, the NG is likely to be caused by the disc. BDP-170...
Page 10
In such a case, close the tray manually then press the [STOP] button to quit Error Rate Measurement mode. (If the [STOP] button is pressed first, close the tray manually afterward to return to the Menu screen.) 5 Quit Service mode by pressing the [STOP] button. BDP-170...
Page 11
[ Effective indications ] Failure in the playback system (block noise, interrupted sound, jumpiness of images, playback stopped in mid-course, frozen image, etc.) Failure judgment of the pickup, by comparing the error rates before and after cleaning of the lens BDP-170...
When the unit is no power condition due to defective of a MAIN BOARD Assy, original barcode data is not able to read out from it. In such a case, read out the data of the barcode label attached to the BD LOADER, referring to the SKT15002 Service Knowhow manual. BDP-170...
USB memory device is finished. At that moment, a "2D_barcode_data.txt" file, in which 64-bit barcode data have been written, is stored in the USB memory device. 6. Quit Service mode by pressing the [STOP] button. BDP-170...
Page 14
USB memory device is finished. 9. Quit Service mode by pressing the [STOP] button. Note: To prevent a future possible writing error, delete the "2D_barcode_data.txt" file from the USB memory device on the PC. BDP-170...
Page 15
1 Press the HOME MENU button to display the HOME MENU screen. 2 Move the cursor to Initial Setup then press the ENTER button. 3 Move the cursor to Options then press the ENTER button. 4 Move the cursor to Update then press the ENTER button. BDP-170...
Page 16
7 After updating is completed, the product will automatically restart. After restarting is finished, unplug the USB storage device. 2. Changing the Destination Setting 1 Display the HOME MENU screen, move the cursor to Initial Setup, then press the ENTER button. BDP-170...
Page 17
ENTER button. ([4] SXE (Russia) [5] PWXE (Oceania) [8] CUXE (U.S.A.)) 5 Turn the unit OFF then back ON again. (Be sure to do this after changing the destination setting.) BDP-170...
Page 18
3 Check that the latest version of the firmware is installed, by selecting Initial Setup > Option > System Information, in that order. Caution: Be sure to write the latest firmware that suits the destination of the product, because the product will not operate properly with the firmware for service, which is used for changing the destination setting. BDP-170...