Introduction
Installing the Subscriber
Unit
Device Management
Technical Specifications
Certification
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM WIN5158-V-GPS

  • Page 1 Preface Introduction Installing the Subscriber Unit RUGGEDCOM WIN5158-V-GPS Device Management Technical Specifications Certification Installation Guide 10/2018 RC1252-EN-04...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM WIN5158-V-GPS   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................v Related Documents ..........................vi Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................2 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 4   RUGGEDCOM WIN5158-V-GPS Table of Contents Installation Guide 4.2  Power Consumption ........................19 4.3  Radio and Modem Specifications ....................19 4.4  Operating Environment ....................... 20 4.5  Mechanical Specifications ......................20 4.6  Dimension Drawings ........................21 Chapter 5 Certification ....................5.1    Approvals ........................... 23 5.1.1    CSA ..........................23 5.1.2  European Union (EU) .......................
  • Page 5: Preface

    Preface Preface This guide describes the RUGGEDCOM WIN5158-V-GPS. It describes the major features of the subscriber unit, installation, commissioning and important technical specifications. It is intended for use by subscriber unit installers and operators, and assumes readers have a working knowledge of WiMAX technologies and procedures.
  • Page 6: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM WIN5158-V-GPS subscriber unit is part of the RUGGEDCOM WIN family, a line of mobile WiMAX broadband wireless access systems based on the IEEE 802.16e mobile WiMAX standard. The RUGGEDCOM WIN5158-V-GPS is a high-performance, self-learning subscriber. It automatically detects the base station on the best signal available, allowing for plug-and-play installation and maintenance free operation.
  • Page 8: Feature Highlights

    The subscriber unit supports both IP convergence sublayer for wireless Internet service providers or Ethernet Convergence Sublayer, ideal for mission critical private networks. Section 1.2 Description The RUGGEDCOM WIN5158-V-GPS features various ports, controls and indicator LEDs on the bottom panel for connecting, configuring and troubleshooting the subscriber unit. RSSI W.LINK PWR Figure 1: RUGGEDCOM WIN5158-V-GPS...
  • Page 9: Required Tools And Materials

    Section 2.6, “Grounding the Subscriber Unit”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM WIN5158-V-GPS: Tools Greases • Wrench or socket set • Marine grease (for marine applications only) • Phillips screwdriver Tapes •...
  • Page 10: Decommissioning And Disposal

    Chapter 1 RUGGEDCOM WIN5158-V-GPS Introduction Installation Guide • UV-resistant vinyl tape Sprays • Electrical insulation putty • Cleaner and de-greaser • SCC3 conformal coating Mounting Hardware (Wall/Tower Only) • Corrosion protection • Four 1/4" × 1/2" HEX chipboard screws • Four 1/4" flat washers •...
  • Page 11: Installing The Subscriber Unit

    WARNING! Safety hazard – risk of serious personal injury and/or damage to equipment. Installing the RUGGEDCOM WIN5158-V-GPS can pose a serious safety hazard. Be sure to take precautions to avoid the following: • Exposure to high voltage lines during installation •...
  • Page 12: General Procedure

    Chapter 2 RUGGEDCOM WIN5158-V-GPS Installing the Subscriber Unit Installation Guide IMPORTANT! This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken.
  • Page 13: Unpacking The Subscriber Unit

    Configure the subscriber unit. For more information, refer to Section 3.1, “Configuring the Subscriber Unit”. Section 2.2 Unpacking the Subscriber Unit The following items are included in the RUGGEDCOM WIN5158-V-GPS package: Item Quantity RUGGEDCOM WIN5158-V-GPS Subscriber Unit Radio Frequency (RF) antenna cables, 5 m (16.4 ft) long...
  • Page 14: Mounting The Subscriber Unit

    Do not attempt to touch or remove the component. Section 2.4 Mounting the Subscriber Unit The RUGGEDCOM WIN5158-V-GPS is designed for maximum mounting and display flexibility. It can be secured to a bracket and then mounted to a pole, wall or tower. Mounting the Subscriber Unit...
  • Page 15: Mounting The Subscriber Unit To A Wall Or Tower

    RUGGEDCOM WIN5158-V-GPS Chapter 2 Installation Guide Installing the Subscriber Unit NOTE For detailed dimensions of the subscriber unit, refer to Section 4.6, “Dimension Drawings”. When choosing the mounting location for the unit, consider the available mounting structures and antenna clearance. Site Survey Most wireless networks include many subscriber/base stations installed in various locations in an overlapping...
  • Page 16 Chapter 2 RUGGEDCOM WIN5158-V-GPS Installing the Subscriber Unit Installation Guide Figure 2: Mounting the Subscriber Unit to a Wall or Tower 1. Subscriber Unit    2. Mounting Kit    3. Wall Holder/Pole Mount    4. M8 × 25 mm Hex Screw    5. M8 Spring Washer    6. M8 Flat Washer    7. M8 Nut    8. M5 Flat Washer    9. NS 1/4" × 1/2" HEX Chipboard Screw    10. Wall Anchor Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, washers and screws.
  • Page 17: Mounting The Subscriber Unit To A Pole

    RUGGEDCOM WIN5158-V-GPS Chapter 2 Installation Guide Installing the Subscriber Unit Section 2.4.2 Mounting the Subscriber Unit to a Pole The subscriber unit can be attached to any pipe or pole with a diameter of 44.5 to 254 mm (1.75 to 10 in).
  • Page 18: Installing The Antennas

    Tighten the screws connecting the clamping bracket to the mounting bracket. Make sure the screws are torqued to 14 N·m (10 lbf-ft). Section 2.5 Installing the Antennas The RUGGEDCOM WIN5158-V-GPS supports N-Connect female antennas. To install an antenna, do the following: Installing the Antennas...
  • Page 19 RUGGEDCOM WIN5158-V-GPS Chapter 2 Installation Guide Installing the Subscriber Unit WARNING! Radiation hazard – risk of Radio Frequency (RF) exposure. This subscriber unit is compliant with the requirements set forth in FCC CFR 47, section 1.1307, addressing Radio Frequency (RF) exposure from...
  • Page 20: Grounding The Subscriber Unit

    Section 2.7 Connecting Power and Data The RUGGEDCOM WIN5158-V-GPS requires a 9 to 36 VDC Class 2 power supply. IMPORTANT! When connecting a DC battery power supply, make sure to use a 36 VDC, 3 A, double-pole circuit breaker as the main disconnecting device.
  • Page 21: Weatherproofing The Subscriber Unit

    Most outdoor subscriber unit, antenna and cable problems are caused by coaxial cable connections loosened by vibration, allowing moisture to penetrate the connector interface. Siemens strongly recommends weatherproofing all outdoor cable connections to prevent the ingress of water and help secure connections.
  • Page 22: Applying Cold Shrink Tubing

    Chapter 2 RUGGEDCOM WIN5158-V-GPS Installing the Subscriber Unit Installation Guide Spray the cable end and connector with SCC3 conformal coating and allow them to dry fully (approximately 3 to 5 minutes depending on the ambient temperature). Apply cold shrink or self-amalgamating tape to the connector end. For information about how to apply these types of seals, refer to Section 2.8.2, “Applying Cold Shrink Tubing”...
  • Page 23: Device Management

    RUGGEDCOM WIN5158-V-GPS Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the subscriber unit. CONTENTS • Section 3.1, “Configuring the Subscriber Unit” Section 3.1 Configuring the Subscriber Unit Once the subscriber unit is installed and connected to the network, it must be configured. The RUGGEDCOM WIN5158-V-GPS features a Web-based User Interface (UI) for all configuration management.
  • Page 24 Chapter 3 RUGGEDCOM WIN5158-V-GPS Device Management Installation Guide Configuring the Subscriber Unit...
  • Page 25: Technical Specifications

    Section 4.4, “Operating Environment” • Section 4.5, “Mechanical Specifications” • Section 4.6, “Dimension Drawings” Section 4.1 Power Supply Requirements The RUGGEDCOM WIN5158-V-GPS requires an external power supply that meets the following requirements: Power Supply Type Class 2 Input Range 10 to 36 VDC Section 4.2 Power Consumption...
  • Page 26: Operating Environment

    -20 to 100 dBm Dynamic Range (Transmitter) -20 to 21 dBm Section 4.4 Operating Environment The RUGGEDCOM WIN5158-V-GPS is rated to operate under the following environmental conditions. Ambient Operating -40 to 75 °C (-40 to 167 °F) Temperature Ambient Storage Temperature -40 to 75 °C (-40 to 167 °F)
  • Page 27: Dimension Drawings

    RUGGEDCOM WIN5158-V-GPS Chapter 4 Installation Guide Technical Specifications Section 4.6 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 44.2 37.0 60.0 92.2 106.8 Figure 6: Overall Dimensions Dimension Drawings...
  • Page 28 Chapter 4 RUGGEDCOM WIN5158-V-GPS Technical Specifications Installation Guide Dimension Drawings...
  • Page 29: Certification

    RUGGEDCOM WIN5158-V-GPS Chapter 5 Installation Guide Certification Certification The RUGGEDCOM WIN5158-V-GPS ODU SU has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 5.1, “Approvals” • Section 5.2, “Environmental Type Tests”...
  • Page 30: European Union (Eu)

    Installation Guide Section 5.1.2 European Union (EU) This subscriber unit is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • IEC/EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 31: Ised

    Certification Section 5.1.4 ISED This subscriber unit is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • RSS-102 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) •...
  • Page 32 Chapter 5 RUGGEDCOM WIN5158-V-GPS Certification Installation Guide Test Description Test Levels -40 °C (-40 °F) for 16 hours -40 °C (-40 °F) for 72 hours IEC 60068-2-2 High Temperature 55 °C (131 °F) for 72 hours 60 °C (140 °F) for 16 hours 70 °C (158 °F) for 72 hours...