I/O Module Installation; Parts Check List - Acer Altos S205F User Manual

Hide thumbs Also See for Altos S205F:
Table of Contents

Advertisement

Figure 2–10

2.7 I/O Module Installation

Warning
Operation of the Enclosure with
not receive sufficient cooling. It is
Dummy Carriers and/or Blank modules are available for this purpose.

2.7.1 Parts Check List

Important
The enclosure may be configured with either one or two I/O modules. If only one I/O module is
fitted it must be installed in rear bay 4 and a Blank I/O module fitted in the unused bay.
• Two RAID I/O Modules ,or one RAID I/O Module with one Blank I/O module for Altos S205F
• Two JBOD I/O Modules ,or one JBOD I/O Module with one Blank I/O module for Altos S200F
Jumper setting for JBOD I/O module: set jumper J7 open. Each connection can see all
drives in the enclosure.
ANY
ESSENTIAL
J7
modules missing will disrupt the airflow and the drives will
that all apertures are filled before operating the unit.