TECH SHEET - DO NOT DISCARD
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
IMPORTANT
Electrostatic Discharge (ESD) Sensitive Electronics
ESD problems are present everywhere. ESD may damage or weaken the
machine control electronics. The new control assembly may appear to
work well after repair is finished, but failure may occur at a later date
due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green ground
connection point or unpainted metal in the appliance
Touch your finger repeatedly to a green ground connection point or
unpainted metal in the appliance.
Before removing the part from its package, touch the anti-static bag
to a green ground connection point or unpainted metal in the
appliance.
Avoid touching electronic parts or terminal contacts; handle machine
control electronics by edges only.
When repackaging failed machine control electronics in anti-static
bag, observe above instructions.
DIAGNOSTIC GUIDE
Before servicing, check the following:
Make sure there is power at the wall outlet.
Has a household fuse blown or circuit breaker tripped? Was a regular fuse
used? Use a time-delay fuse.
Is dryer vent properly installed and clear of lint or obstructions?
All tests/checks should be made with a VOM (volt-ohm-milliammeter) or DVM
(digital-voltmeter) having a sensitivity of 20,000 Ω per volt DC or greater.
Check all connections before replacing components. Look for broken or loose
wires, failed terminals, or wires not pressed into connectors far enough.
A potential cause of a control not functioning is corrosion on connections.
Observe connections and check for continuity with an ohmmeter.
Connectors: Look at top of connector. Check for broken or loose wires. Check
for wires not pressed into connector far enough to engage metal barbs.
Resistance checks must be made with dryer unplugged or power disconnected.
DIAGNOSTIC TESTS
These tests allow factory or service personnel to test and verify all inputs to the
machine control electronics. You may want to do a quick and overall checkup of
the dryer with these tests before going to specific troubleshooting tests.
ACTIVATING THE DIAGNOSTIC TEST MODE
1. Be sure the dryer is in standby mode (plugged in with all indicators off, or
with only the Done indicator on).
2. Select any one button (except Pause/Cancel) and follow the steps below,
using the same button (remember the button):
Press/hold
Release for
2-5 seconds
2-5 seconds
FOR SERVICE TECHNICIAN'S USE ONLY
-OR-
Press/hold
Release for
Press/hold
2-5 seconds
2-5 seconds
2-5 seconds
3. If this test mode has been entered successfully, all indicators on the console
are illuminated for 5 seconds with
Remaining two-digit display.
DIAGNOSTIC: Unsuccessful Entry
If entry into diagnostic mode is unsuccessful, press the Pause/Cancel button
twice, then press the Power button.
If indicators come on, try to use a different button than was used to activate
the diagnostic test mode. If that button fails to enter the diagnostic mode,
something is faulty, and it is not possible to enter the diagnostic mode. Go to
TEST #2, page 4.
If no indicators come on after pressing the Power button, go to TEST #1,
page 4.
DIAGNOSTIC: Saved Fault Codes
If there are saved fault codes, the most recent fault code will alternately show "F-"
and "XX" where XX is the fault code.
Press and release
the same button
beep tone
used to activate
Diagnostics
Repeat
beep tone
Repeat
beep tone
Repeat
All indicators momentarily turn off, then stay on.
DIAGNOSTIC: Console Buttons and Indicators
Pressing the console buttons or rotating the cycle selector will sound a beep and
will turn on or off the corresponding indicators as shown in Figure 1, Console
Diagnostics, page 2. Pressing Time Adjust
turn the left digit of the display on or off. Pressing Time Adjust
sound a beep and turn the right digit of the display on or off.
If indicators fail to turn on or off and beep after pressing buttons or
rotating the cycle selector, go to TEST #6, page 8.
DIAGNOSTIC: Door Switch
Opening the door should cause a beep and an alphanumeric number to be
displayed. Closing the door should cause a beep and
If opening the door fails to cause a beep and a number and letter to be
displayed, go to TEST #7, page 8.
DIAGNOSTIC: Moisture Sensor
1. Open the door and locate two metal strips on the inside of the dryer. Using a
wet cloth or one finger, jointly touch both strips.
If a continuous beep tone is heard and an alphanumeric number is
displayed on the console, the sensor is OK.
If a continuous beep tone is not heard, or if a continuous beep tone is
heard before touching both moisture strips, go to step 2.
2. Check to see if there is water in the dryer around the moisture strips.
If no water is present, go to TEST#5, page 7.
If water is present, wipe the strips off with a dry cloth and repeat step 1.
If wiping the strips does not stop the beeping, run a timed dry cycle for
2 minutes to dry out the drum, then repeat this diagnostic test.
DIAGNOSTIC: Motor, Heater, and Console ID
Close the door. Press the Start button. The motor and heater will turn on, and the
display will show one of the following console IDs:
C7
C8
C9
,
, or
.
If none of the Console IDs listed above are displayed, replace the user
interface assembly. See Accessing & Removing the Electronic Assemblies,
page 9.
If the motor does not turn on, go to TEST #3, page 5.
If no heat is detected, go to TEST #4, page 6.
PAGE 1
88
showing in the Estimated Time
Second most recent fault code is displayed.
Third most recent fault code is displayed.
Fourth most recent fault code is displayed.
(more time) will sound a beep and
(less time) will
88
to be displayed.
C0
C1
C2
C3
C4
,
,
,
,
PART NO. W10156037A
C5
C6
,
,
,

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool WED6600VU0

  • Page 1 TECH SHEET - DO NOT DISCARD PAGE 1 3. If this test mode has been entered successfully, all indicators on the console WARNING are illuminated for 5 seconds with showing in the Estimated Time Remaining two-digit display. Electrical Shock Hazard DIAGNOSTIC: Unsuccessful Entry Disconnect power before servicing.
  • Page 2 TECH SHEET - DO NOT DISCARD PAGE 2 Power button controls Start button turns on dryer. Status indicators at right. Rotating knob turns indicators on or off. “Less Time” button “More Time” button Dryness button controls Temperature button controls Each button controls Turns off all indicators and turns the right digit of turns the left digit of...
  • Page 3: Display Fault Codes

    TECH SHEET - DO NOT DISCARD PAGE 3 Steam Model DISPLAY DESCRIPTION EXPLANATION / RECOMMENDED PROCEDURE 2. Motor + heater + water valve. Flash “Delicate” LED. F-30 flashes if a restricted air flow condition Motor + heater + water valve + drum Restricted exists.
  • Page 4: Troubleshooting Tests

    TECH SHEET - DO NOT DISCARD PAGE 4 6. Access the machine control electronics without disconnecting any wiring to the control board. See Accessing & Removing the Electronic See Accessing & Removing the Electronic Assemblies, page 10, to access: Assemblies, page 9. User Interface Assembly 7.
  • Page 5 TECH SHEET - DO NOT DISCARD PAGE 5 WINDING RESISTANCE CONTACT POINTS OF TEST #3 Drive Motor Circuit Ω MEASUREMENT This test will check the wiring to the motor and the Blue wire in back at motor itself. The following items are part of this pin 4 and bare copper motor system: MAIN...
  • Page 6: Exhaust Thermistor

    TECH SHEET - DO NOT DISCARD PAGE 6 5. Measure the resistance between the red wires at If wire connections are OK, check the exhaust TEST #4 Heater the heater. thermistor resistance per step 5. This test is performed when one of the following If an open circuit is not detected: 4.
  • Page 7 TECH SHEET - DO NOT DISCARD PAGE 7 Check wire connections at the machine TEST #4c Thermal Cut-Off Sensor Harness control electronics and inlet thermistor. See with MOVs Accessing & Removing the Electronics If the dryer does not produce heat, check the status Sensor (Metal Oxide Assemblies, page 9, and for inlet thermistor...
  • Page 8: Adjusting Customer- Focused Drying Modes

    TECH SHEET - DO NOT DISCARD PAGE 8 9. If water is still not dispensed: TEST #6 Buttons and TEST #7 Door Switch Unplug or disconnect dryer. Indicators Activate the diagnostic test mode as shown on Replace the machine control electronics as page 1, and perform the Door Switch Diagnostic test, This test is performed when any of the following shown in “Accessing &...
  • Page 9: Removing The Front Panel/Drum Assembly

    TECH SHEET - DO NOT DISCARD PAGE 9 10. Lower components can be accessed at this 1. Unplug dryer or disconnect power. REMOVING THE FRONT time, however, if the drum is to be removed, the 2. Remove two screws from the rear of the console PANEL/DRUM ASSEMBLY belt must be removed.
  • Page 10: Removing The Back Panel

    TECH SHEET - DO NOT DISCARD PAGE 10 Cycle Selector Switch Locking Tabs User Interface Assembly Figure 17. Gently apply pressure to locking tabs to release the user interface assembly. Reinstalling the Electronic Assemblies Refer to preceding removal sections and replace in reverse order.
  • Page 11 TECH SHEET - DO NOT DISCARD PAGE 11 ELECTRIC DRYER WIRING DIAGRAMS IMPORTANT: Electrostatic (static electricity) discharge may cause damage to machine control electronics. See page 1 for details. SINGLE ELEMENT MODEL L1 LINE – BK R – LINE L2 240 VOLTS W –...
  • Page 12 TECH SHEET - DO NOT DISCARD PAGE 12 ELECTRIC DRYER WIRING DIAGRAM IMPORTANT: Electrostatic (static electricity) discharge may cause damage to machine control electronics. See page 1 for details. STEAM MODEL R – LINE L2 L1 LINE – BK 240 VOLTS W –...

This manual is also suitable for:

Wed6600wl0Wed6600vw0

Table of Contents