YOUR SAFETY FIRST BEFORE YOU START • Proper installation is the installer's responsibility! – Read the entire manual before you begin. The Model number label is located on the front of oven, behind doon See Figure 1. Mounting plate is located on back side of microwave oven. See Figure 2.
Page 3
YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! – If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
Page 4
YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. – Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. –...
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. Damper/duct connector One power cord clamp and (for roof venting or wall venting installation) One dark-colored mounting screw Not Actual Size (2 pieces must be assembled as (to hold the power cord) shown)
Page 6
PARTS, TOOLS, MATERIALS You will need the following tools and materials for the installation: Carton or other heavy material for covering the counter top. Clear Tape Stud Finder (for taping the templates to the wall) Keyhole Saw (for the power cord hole) Saber Saw (for cutting vent holes for roof or wall venting)
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS W A R N I N G AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 5. Upper NOTE: The outlet should be on a circuit dedicated to the Cabinet...
STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 10, page 9. W A R N I N G THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways.
Page 9
Standard Fittings NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper’s sticking. Duct Length The total length of the duct system, including straight duct, elbows, transitions, and wall or roof caps must not exceed the equivalent of 140 feet.
STEP 3: PREPARE THE VENTING BLOWER W A R N I N G To avoid risk of property damage, unplug the microwave oven or disconnect power at ● source by removing fuse or throwing circuit breaker. ● To avoid risk of personal injury, wear protective gloves when handling mounting plate. DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock.
4. Reassemble the blower wire. See Figure 15. 5. Rotate the unit so that the exhaust ports face the rear of the cabinet. See Figure 17. When you insert blower unit, blower wire must be like figure 16. 6. Place blower unit back into cabinet. Check that the exhaust ports face towards the rear of the cabinet. See Figure 7.
Page 12
STEP 4: PREPARE THE WALL & UPPER CABINET W A R N I N G To avoid personal injury or property damage, do not attempt to install this microwave oven if you cannot find a wall stud. Measure And Track/Tape Up The Templates 1.
W A R N I N G To avoid risk of personal injury, electrical shock or death: Note where electrical outlets and electrical wires are before you drill into the wall. Locate and disconnect power to any electrical circuits that could be affected by installing this oven.
STEP 5: INSTALL THE MOUNTING PLATE The Oven Must Be Connected To At Least One 3/16 Hole on Studs 5/8 Hole on Dry wall Only Wall Stud. " Minimum 66 From the Floor 1. Draw a vertical line on the wall at the center of the 30 wide For Wall- space.
Page 15
For Wall-Vented Make the box cutout for the rear wall duct. – 1 piece mounting plate: Using a pencil, put dots through slots F and G, and through holes H and I. Remove the mounting plate and draw lines extending through the points. This will give the location and size of the box cutout for the rear wall duct.
STEP 6: ATTACH THE OVEN TO THE WALL W A R N I N G To avoid risk of personal injury or property damage, use will need two people to install this microwave oven. 1. Carefully lift microwave oven and hang it on support tabs (See Figure 28) at the bottom of the mounting power cord plate.Reaching through upper cabinet, thread...
Page 17
STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof venting installation: See Figure 34. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See "Prepare The Venting System"...