WARNING
© Copyright 2016 ABB. All rights reserved.
Safety
Safe operation and maintenance
Safety during start-up / commissioning and operation
The turbine casing insulation of the TPS44-F supplied by ABB Turbo
Systems is also burst protection.
Serious personal injuries or fatal accidents can occur, if the turbine cas-
ing insulation of the TPS44-F supplied by ABB Turbo Systems is re-
moved. The burst protection is integrated into the turbine casing insula-
tion of the TPS44-F supplied by ABB Turbo Systems.
Separate burst protection is fitted to TPS44-F turbochargers without in-
sulation that have been ordered from ABB Turbo Systems.
Never operate TPS44-F turbochargers that have been supplied by
ABB Turbo Systems with insulation if this insulation from ABB Turbo
Systems is not in place.
Never operate turbochargers without burst protection. If the insula-
tion from ABB Turbo Systems is not in place, the separate burst pro-
tection (57200) must be fitted before operation. (See View of tur-
bocharger showing part numbers [➙ 126].)
Before starting work, carry out visual inspection of working area.
Remove any obstacles and objects lying around.
Before start-up / commissioning, check all pipes from and to turbo-
charger for damage and leaks.
Don't work in any way that could impair safety when working on turbo-
charger.
After about every 12 hours of operation or at least once a day, inspect
turbocharger for visible damage and defects.
Immediately report any damage or changes in operational perfor-
mance to person responsible.
If damage is discovered, immediately shut down turbocharger and se-
cure it against inadvertent or unauthorized use.
When switching on auxiliary power sources (hydraulics, pneumatics,
electricity, water), keep an eye open for any hazards resulting from
supplying these power sources.
Safety during cleaning
If cleaning agents or solvents are used for cleaning, the corresponding
material safety data sheet and the safety instructions in section "Hazards
due to operating and auxiliary materials" must be observed.
Observe the material safety data sheet for the cleaning agent or solvent.