hit counter script
NEC UNIVERGE SV8100 System Hardware Manual
Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

System Hardware Manual
Doc. No. 10536
Issue 1.5

Advertisement

Table of Contents
loading

Summary of Contents for NEC UNIVERGE SV8100

  • Page 1 System Hardware Manual Doc. No. 10536 Issue 1.5...
  • Page 3 NEC Australia Pty Ltd. This document has been prepared for the use of employees and customers of NEC Australia Pty Ltd and may not be reproduced without prior written approval of NEC Australia Pty Ltd. Copyright © 2007 NEC Australia Pty Ltd 633 –...
  • Page 5 This chapter provides important regulatory information. Chapter 1 – Introduction to SV8100/SV8300 This chapter provides an overview of the UNIVERGE SV8100/SV8300 system. Chapter 2 – SV8100 System Specifications This chapter contains detailed specifications for the SV8100 system and should be carefully reviewed by the technician before installing the system.
  • Page 6 Chapter 12 – Installing D Series i Telephones term The UNIVERGE SV8100/SV8300 system supports several different IPK II D Series i Multiline Terminals and an Attendant Console. This chapter describes each terminal and the console and provides instructions for attaching the terminals to the system and for wall mounting.
  • Page 7 Other manuals in the set are described below. OCUMENTS Documents supporting the SV8100 system include: UNIVERGE SV8100 Features and Specifications Manual This manual describes each available feature for the SV8100 system. UNIVERGE SV8100 General Description Manual This manual contains general information about the system features, configuration and standards.
  • Page 8 Documents supporting the SV8300 system include: UNIVERGE SV8300 System Manual Contains the system description, hardware installation procedure and the programming procedure of the SV8300 system. UNIVERGE SV8300 Command Manual Contains the Customer Administration Terminal (CAT) operation, command functions and data required for programming the system and the Resident System Program. UNIVERGE SV8300 Programming Manual Contains procedure for programming each business, hotel, ISDN, OAI, WCS and WLAN feature.
  • Page 9 In the event of equipment malfunction, all repairs must be performed by an authorised dealer of NEC Australia Pty Ltd or by NEC Australia Pty Ltd. It is the responsibility of users requiring service to report the need for service to one of NEC Australia Pty Ltd authorised agents or to NEC Australia Pty Ltd.
  • Page 10 The Australian Performing Right Association Limited (APRA), or other similar organisation, when radio or TV broadcasts are transmitted through the Music On Hold feature of this telecommunication system. NEC Australia Pty Ltd hereby disclaims any liability arising out of the failure to obtain such a license.
  • Page 11 ATTERY ISPOSAL AND AFETY The UNIVERGE SV8100 system includes the batteries listed below. When disposing of these batteries from system chassis, blades or external battery boxes, the maintenance personnel must comply with applicable Federal and State regulations regarding proper disposal procedures.
  • Page 13: Table Of Contents

    Table of Contents Chapter 1 Introduction to SV8100/SV8300 Section 1 General Information ..................1-1 Section 2 Equipment List .................... 1-4 Chapter 2 SV8100 System Specifications Section 1 General Information ..................2-1 Section 2 System Block Diagram ................2-1 Section 3 Maximum System Capacities ..............
  • Page 14 Issue No. 1.5 UNIVERGE SV8100/SV8300 6.6.6 External Tone Ringer/Night Chime Output ....... 2-23 6.6.7 SMDR Output ..............2-23 6.6.8 PC Connection ..............2-24 6.6.9 Relay Contact ..............2-24 Battery Backup ................2-24 6.7.1 System Backup (Optional) ..........2-24 6.7.2 Memory Backup ............... 2-24 Weights and Dimensions ...............
  • Page 15 UNIVERGE SV8100/SV8300 Issue No. 1.5 Dialing Specifications ..............3-22 6.6.1 Dial Pulse Address Signaling ........... 3-22 6.6.2 Dual-Tone Multifrequency (DTMF) Address Signaling ..3-22 6.6.3 External Equipment Connection ........3-23 6.6.4 Music Source for Music on Hold via Chassis ....3-23 6.6.5...
  • Page 16 Issue No. 1.5 UNIVERGE SV8100/SV8300 Section 3 Installing the Chassis ................... 4-5 Wall Mounting the 19” Chassis ............4-6 3.1.1 CHS2U-AU Chassis Wall Mount Installation ...... 4-6 Floor Mounting the 19” Chassis ............. 4-13 3.2.1 CHS2U-AU Chassis Installation ........4-13 3.2.2...
  • Page 17 UNIVERGE SV8100/SV8300 Issue No. 1.5 Chapter 5 Installing the SV8300 Chassis Section 1 General Information ..................5-1 Section 2 Site Preparation and MDF/IDF Construction ..........5-1 Precautionary Information ..............5-1 Surveying the Customer Site ............5-2 Selecting the Best Location for Proper Installation ......5-2 2.3.1...
  • Page 18 Issue No. 1.5 UNIVERGE SV8100/SV8300 Section 4 Battery Connection ..................5-47 Install Internal Batteries ..............5-47 4.1.1 Install Internal Batteries CHS1U-AU Chassis ....5-47 4.1.2 Install Internal Batteries CHS2U-AU Chassis ....5-52 Install External Batteries (without CHS LARGE BATT BOX) ..5-57 Install External Batteries (with CHS LARGE BATT BOX) ....
  • Page 19 UNIVERGE SV8100/SV8300 Issue No. 1.5 Section 3 Common Control Blades ................6-13 CD-CP00-AU (SV8100 Central Processing Unit) ......6-13 3.1.1 Description ............... 6-14 3.1.2 Installation ................ 6-17 3.1.3 Switch Settings ..............6-18 3.1.4 LED Indications ..............6-19 3.1.5 Connectors ............... 6-20 CC-CP00 (SV8300 Central Processing Unit) ........
  • Page 20 Issue No. 1.5 UNIVERGE SV8100/SV8300 CD-4LCA/ CD-8LCA (4-Port/8-Port Single Line Interface) ..... 6-48 4.3.1 Description ............... 6-49 4.3.2 Installation ................ 6-50 4.3.3 Connectors ............... 6-51 PZ-4LCA/PZ-8LCE (4-Port/8-Port SLI Daughter Boards) ....6-52 4.4.1 Description ............... 6-53 4.4.2 Installation ................ 6-54 4.4.3...
  • Page 21 UNIVERGE SV8100/SV8300 Issue No. 1.5 CD-PRTA (Primary Rate Interface) ..........6-77 5.6.1 Description ............... 6-77 5.6.2 Installation ................ 6-78 5.6.3 LED Indications ..............6-79 5.6.4 Connectors ............... 6-81 CD-4ODTA (4-Port Tie Line Interface Blade) ........ 6-83 5.7.1 Description ............... 6-83 5.7.2...
  • Page 22 Issue No. 1.5 UNIVERGE SV8100/SV8300 Chapter 7 Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals Section 1 General Description ..................7-1 Section 2 DT300 Series Digital Multiline Terminals ............. 7-6 Digital MultilineTerminals ..............7-6 2.1.1 DTL-2E-1( ) (BK) TEL ............7-6 2.1.2...
  • Page 23 UNIVERGE SV8100/SV8300 Issue No. 1.5 Installing a Numbered Keypad on the Multiline Terminal ....7-31 4.7.1 Installing the Numbered Keypad on a Multiline Terminal 7-32 4.7.2 Configuring the Digital Telephone for the Numbered Keypad .. 7-34 4.7.3 Configuring the IP Telephone for the Numbered Keypad 7-35 Adjusting the Height on the Multiline Terminal .......
  • Page 24 ................. 8-16 Chapter 9 Installing SV8100/SV8300 Wireless Telephones Section 1 General Description ..................9-1 Section 2 NEC SIP DECT Solutions ................9-1 Installation ..................9-2 Chapter 10 Installing SV8100/SV8300 Optional Equipment Section 1 General Information ................... 10-1 Section 2 PGD(2)-U( ) ADP ..................
  • Page 25 UNIVERGE SV8100/SV8300 Issue No. 1.5 Section 3 Background Music ..................10-9 Installing Background Music ............10-9 Section 4 Door Box ....................10-10 Installing a Door Box ..............10-10 Section 5 External Paging ..................10-14 External Page ................10-14 Installing an External Page System ..........10-14 Section 6 External Paging and Door Box/Page Relays ...........
  • Page 26 Issue No. 1.5 UNIVERGE SV8100/SV8300 11.3.4 VSR Record Tab ............10-33 11.3.5 About Tab ............... 10-34 11.3.6 Options Tab ..............10-35 11.3.7 File Management Tab ............ 10-37 11.3.8 Custom Program Settings ..........10-37 11.4 Operation Note ................10-39 11.5 4-Port Digital Call Logging Unit ............ 10-40 11.5.1...
  • Page 27 UNIVERGE SV8100/SV8300 Issue No. 1.5 Section 13 Power Failure Telephones ............... 10-75 13.1 Power Failure ................10-75 13.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits .. 10-76 13.3 Installing the Power Failure Telephones ........10-76 term Chapter 11 Installing D...
  • Page 28 Issue No. 1.5 UNIVERGE SV8100/SV8300 Section 11 Wall Mounting Multiline Terminals ............11-16 11.1 Wall Mounting a Multiline Terminal using the Base Plate .... 11-17 11.1.1 Adjusting the Hanger Hook ..........11-17 11.1.2 Wall Mounting the Multiline Terminal ......11-17 11.1.3...
  • Page 29 Installing the External Microphone ......... 12-23 Add on Module (ADM) ..............12-23 4.2.1 Connecting the Interface Unit ........12-24 4.2.2 Wall Mounting ADM and Multiline Terminal ....12-25 NEC Push-to-Mute (PTM) or Push-to-Talk (PTT) Handset ..12-27 4.3.1 Description ..............12-27 System Hardware Manual xvii...
  • Page 30 Issue No. 1.5 UNIVERGE SV8100/SV8300 THIS PAGE INTENTIONALLY LEFT BLANK xviii Table of Contents...
  • Page 31 List of Figures Figure 1-1 Simplified SV8100 System Connectivity ..........1-2 Figure 1-2 Simplified SV8300 System Connectivity ..........1-2 Figure 2-1 SV8100 System Block Diagram ............2-3 Figure 2-2 19” Controlling and Expansion Chassis ..........2-5 Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable ......2-16 Figure 3-1 SV8300 System Block Diagram ............
  • Page 32 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 4-16 Assemble Stand Mount with Screws ..........4-17 Figure 4-17 Secure CHS2U-AU Chassis to CHS2U STAND KIT with Screws ..4-18 Figure 4-18 Secure Stand Mount to Floor with Screws ........4-19 Figure 4-19 Attach Rubber Feet to CHS2U-AU Chassis ........
  • Page 33 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 4-44 19” Chassis Grounding Lug (Multiple-Chassis) ........ 4-35 Figure 4-45 Install the AC Power Cord ..............4-36 Figure 4-46 Install 19” AC Power Cords (Multiple-Chassis) ........ 4-36 Figure 4-47 Removing Battery Access Panel ............4-37 Figure 4-48 Removing Access Panel ..............
  • Page 34 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 4-72 Removing CHS LARGE BATT BOX Cover ........4-51 Figure 4-73 Removing Battery Tray Suppressor ..........4-52 Figure 4-74 Disconnecting Battery Cables ............4-52 Figure 4-75 CHS LARGE BATT BOX Fuse Unit ..........4-53 Figure 4-76 Connecting Battery Cables ...............
  • Page 35 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 5-20 Stand Mount Spacing Guide (CHS1U-AU+CHS2U-AUx1 Chassis Installation) ................. 5-20 Figure 5-21 Attach Rubber Feet to CHS2U-US Chassis ........5-21 Figure 5-22 Install Joint Brackets with Screws ............ 5-21 Figure 5-23 Assemble Stand Mount with Screws ..........5-22 Figure 5-24 Attach Floor Mount Brackets to Chassis with Screws ......
  • Page 36 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 5-45 PZ-BS10 Blade Installed ..............5-39 Figure 5-46 PZ-BS10 Installed (Cover Closed) ............ 5-39 Figure 5-47 PZ-BS11 Expansion Bay in Expansion Chassis ....... 5-39 Figure 5-48 Open Expansion Chassis Cover ............5-40 Figure 5-49 PZ-BS11 Blade Guides ..............
  • Page 37 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 5-73 Installing Two Batteries ..............5-54 Figure 5-74 Installing Battery Cable ..............5-55 Figure 5-75 Connecting CHS2U BATT CA INT ........... 5-55 Figure 5-76 Installing Battery Tray into CHS2U-AU Chassis ....... 5-56 Figure 5-77 Installing the Access Panel ..............
  • Page 38 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 5-99 Cable Connection between Chassis and CHS LARGE BATT BOX (3 Hours Battery Backup) ........5-69 Figure 5-100 Removing CHS LARGE BATT BOX Cover ........5-69 Figure 5-101 Removing Battery Tray Suppressor ..........5-70 Figure 5-102 Disconnecting Battery Cables ............
  • Page 39 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 6-16 CD-4LCA Blade ................6-48 Figure 6-17 CD-8LCA Blade ................6-49 Figure 6-18 Installing the PZ-4LCA Daughter Board ........... 6-52 Figure 6-19 Installing the PZ-8LCE Daughter Board ........... 6-53 Figure 6-20 CD-LTA Blade .................. 6-56 Figure 6-21 CD-4COTC Blade ................
  • Page 40 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 7-3 DTL-8LD-1( ) TEL ................7-8 Figure 7-4 DTL-12D-1( ) TEL ................7-9 Figure 7-5 DTL-12PA-1( ) TEL ................7-10 Figure 7-6 DTL-24D-1( ) TEL ................7-11 Figure 7-7 DTL-32D-1( ) TEL ................7-12 Figure 7-8 ITL-2E-1( ) TEL .................
  • Page 41 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 7-31 BS (Retro)-L KIT ................7-32 Figure 7-32 Remove Plastic Panels ..............7-32 Figure 7-33 Removing Numbered Keypad from DT300/DT700 Series Terminal ................7-33 Figure 7-34 Install New Numbered Keypad into DT300/DT700 Series Terminal ................7-33 Figure 7-35 Install Plastic Panels ................
  • Page 42 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 7-58 8LKD (LD)-L UNIT Installed .............. 7-49 Figure 7-59 Install Screw ..................7-50 Figure 7-60 8LKI (LD)-L( ) UNIT ................7-50 Figure 7-61 Remove Side Panel from Multiline Terminal ........7-51 Figure 7-62 Ribbon Cable Connector ..............7-52 Figure 7-63 Ribbon Cable Installed ..............
  • Page 43 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 7-86 ITL / DTL PTT Handset ..............7-65 Figure 7-87 Installing the UTR-1-1( ) USB Handset Cable ........7-66 Figure 7-88 Installing the UTR-1-1( ) USB Handset to a PC ....... 7-66 Figure 7-89 Wall Mounting the UTR-1-1( ) USB Handset ........
  • Page 44 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 8-21 Removing the Connector Cover ............8-15 Figure 8-22 Installing the BHA-L UNIT ..............8-16 Figure 8-23 Entering a PIN Code ................. 8-16 Figure 8-24 Pairing a Device ................8-17 Figure 8-25 Connecting the Paired Device ............8-17 Figure 8-26 Unpairing a Device ................
  • Page 45 VSR Reporter Pro Screen ............. 10-53 Figure 10-44 Installing Adapters ................10-56 Figure 10-45 In-Line Power Adapter ..............10-57 Figure 10-46 In-Line Power Adapter Switch Settings .......... 10-58 Figure 10-47 NEC Terminal Connection to an IEEE 802.3af PoE Switch ... 10-59 System Hardware Manual xxxiii...
  • Page 46 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 10-48 ADA-L( ) Unit .................. 10-60 Figure 10-49 Separate Tilt Leg from Leg Support ..........10-62 Figure 10-50 Bottom Option Interface Knockout ..........10-62 Figure 10-51 Install ADA-L( ) Unit ................ 10-62 Figure 10-52 ADA-L( ) OUT Jack Connection ............
  • Page 47 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 11-4 DTH-8D-1( ) TEL Multiline Terminal ..........11-4 Figure 11-5 DTH-16-1( ) TEL Multiline Terminal ..........11-4 Figure 11-6 DTH-16D-1( ) TEL Multiline Terminal ..........11-5 Figure 11-7 DTH-16(BL)-1( ) TEL Multiline Terminal ........... 11-6 Figure 11-8 DTH-16LD-1( ) TEL Multiline Terminal ..........
  • Page 48 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 11-32 Wall Mounting the Base Plate ............11-19 Figure 11-33 Installing the Multiline Terminal ............11-19 Figure 11-34 Plugging in Line Cord into Multiline Terminal ......... 11-20 Figure 11-35 Hiding Excess Cord ................ 11-20 Figure 11-36 Removing the Multiline Terminal ............
  • Page 49 ADM and Multiline Terminal with Base Covers Removed ....12-24 Figure 12-32 Installing the Connector Plate ............12-25 Figure 12-33 Installing Base Units on the Wall ............ 12-26 Figure 12-34 NEC PTM or PTT Handset ............. 12-27 System Hardware Manual xxxvii...
  • Page 50 Issue No. 1.5 UNIVERGE SV8100/SV8300 THIS PAGE INTENTIONALLY LEFT BLANK xxxviii List of Figures...
  • Page 51 List of Tables Table 1-1 Chassis Equipment List ..............1-4 Table 1-2 Chassis Installation Equipment List ............ 1-5 Table 1-3 Battery Mount Equipment List ............1-5 Table 1-4 Blade Equipment List ................. 1-6 Table 1-5 Cable Equipment List ................. 1-7 Table 1-6 Digital Multiline Terminal (DT300 Series) Equipment List ....
  • Page 52 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-19 Tone Patterns ................... 2-28 Table 2-20 Multiline Terminal LED Flash Pattern ..........2-29 Table 2-21 Traffic Capacity ................. 2-30 Table 3-1 List of Abbreviations ................3-1 Table 3-2 SV8300 Maximum System Capacity ..........3-5 Table 3-3 Maximum System Capacity –...
  • Page 53 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 4-4 CHS LARGE BATT BOX Capacity ........... 4-42 Table 5-1 Power Failure Transfer Connections ..........5-4 Table 5-2 PZ-BS10/PZ-BS11 Connector Pin-Out ..........5-36 Table 5-3 Battery Capacity of Single External Battery ........5-61 Table 5-4 Battery Capacity of Multiple External Batteries ........
  • Page 54 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-24 CD-4LCA/CD-8LCA RJ-61 Cable Connector Pin-Outs ..... 6-51 Table 6-25 PZ-4LCA/PZ-8LCE/ RJ-61 Cable Connector Pin-Outs ....6-55 Table 6-26 CD-LTA Maximum Capacities ............6-57 Table 6-27 CD-LTA LED Indications ..............6-58 Table 6-28 CD-LTA RJ11 Cable Connector Pin-Outs ........6-59 Table 6-29 CD-4COTC LED Indications .............
  • Page 55 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 7-4 Terminal and Tenkey Kit Compatibility ..........7-4 Table 7-5 Terminal and Optional Equipment Compatibility ........ 7-5 Table 7-6 Numbered Keypad Type ..............7-28 Table 7-7 Keypad Kit Type ................7-29 Table 7-8 Line Key Kit Type ................7-30 Table 7-9 Numbered Keypad Type ..............
  • Page 56 Issue No. 1.5 UNIVERGE SV8100/SV8300 THIS PAGE INTENTIONALLY LEFT BLANK xliv List of Tables...
  • Page 57: General Information

    Introduction to SV8100/SV8300 ENERAL NFORMATION ECTION The SV8100/SV8300 is a full-featured IP based communications system providing a rich feature set of existing system, with pure Voice over IP (VoIP) communications, across corporate Local and Wide Area Networks (LAN and WAN). The DT700 series telephones provide a converged infrastructure at the desktop, with a 10Base-T/100Base-TX connection to the LAN and built-in hub for a PC connection to the telephone itself.
  • Page 58: Figure 1-1 Simplified Sv8100 System Connectivity

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 1-1 Simplified SV8100 System Connectivity Figure 1-2 Simplified SV8300 System Connectivity 1 - 2 Introduction to SV8100/SV8300...
  • Page 59 UNIVERGE SV8100/SV8300 Issue No. 1.5 Highlights of the UNIVERGE SV8100/SV8300 are as follows: Pure IP System Capable TDM Configuration The SV8100/SV8300 supports both pure IP switching (peer-to-peer connections) and Time Division Switching. The pure IP switching is provided for communications between DT700 series telephones and for CCIS / Remote Unit connections with other SV8100/SV8300/SV7000.
  • Page 60: Equipment List

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Universal Blade Slot (19” Chassis) A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six universal slots and one expansion slot. Also, the universal slots can be used for special application blades without complicated limitation. This makes easy quotation and installation.
  • Page 61: Table 1-2 Chassis Installation Equipment List

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 1-2 Chassis Installation Equipment List Stock Number Equipment Name Equipment Description Product Code 4422002 CHS BASE UNIT Floor Mount Set for all chassis (CHS1U-AU SV8100/SV8300 and CHS2U-AU) 4422006 CHS2U BLANK SLOT COVER Blank Slot Cover Set...
  • Page 62: Table 1-4 Blade Equipment List

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 1-4 Blade Equipment List Stock Number Equipment Name Abbreviations Equipment Description Product Code 4421004 CD-CP00-AU Main Processor Blade for SV8100 SV8100 4420005 CC-CP00 Main Processor Blade for SV8300 SV8300 4422014 PZ-BS10 BUS0 Expansion Chassis Interface Unit, 3-jack...
  • Page 63: Table 1-5 Cable Equipment List

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 1-5 Cable Equipment List Stock Number Equipment Name Equipment Description Product Code 4420007 CHS1U BATT CA INT BATT CHS1U-AU Battery cable for internal battery SV8300 Cable – 10.63ln/270mm 4420008 RS CONSOLE CA-A MAT (PCPro) Cable 6.6 ft. (2.0m)
  • Page 64: Table 1-8 Dt300/Dt700 Series Optional Equipment List

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 1-8 DT300/DT700 Series Optional Equipment List Stock Number Equipment Name Equipment Description Product Code 4424017 APR-L( ) UNIT Analog Port Ringer SV8100 4424018 ADA-L( ) UNIT Ancillary Device Adapter SV8100 4424019 BHA-L UNIT Bluetooth® Hub Adapter...
  • Page 65 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 1-8 DT300/DT700 Series Optional Equipment List (Continued) Stock Number Equipment Name Equipment Description Product Code 4424025 BS (S)-L( ) (BK) KIT Spanish Keypad SV8100/SV8300 4424026 BS (ACD)-L( ) (BK) KIT ACD Support Keypad SV8100/SV8300...
  • Page 66 Issue No. 1.5 UNIVERGE SV8100/SV8300 - - NOTES - - 1 - 10 Introduction to SV8100/SV8300...
  • Page 67: Chapter 2 Sv8100 System Specifications

    SV8100 System Specifications ENERAL NFORMATION ECTION This chapter provides detailed specifications for the SV8100 system technician. The technician should review this information carefully before installing the system. YSTEM LOCK IAGRAM ECTION Figure 2-1 SV8100 System Block Diagram shows the Blades that can be installed in the chassis and the number of channels supported when the Blade is installed.
  • Page 68 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-1 List of Abbreviations (Continued) Abbreviation Description Intermediate Distribution Frame IP Trunk (P2P CCIS) (on CPU) ISDN Integrated Service Digital Network Local Area Network Single Line Telephone Interface Blade LCDB Expansion Single Line Telephone Interface Blade on LC...
  • Page 69 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 2-1 SV8100 System Block Diagram System Hardware Manual 2 - 3...
  • Page 70: Maximum System Capacities

    Issue No. 1.5 UNIVERGE SV8100/SV8300 AXIMUM YSTEM APACITIES ECTION The CHS2U-AU/EU/OT/US is a compact 19” chassis that has six universal slots, one expansion slot and one MPS7101 (power supply unit). When the CD-CP00-AU/EU/ OT/US is installed in the first CHS2U-AU/EU/OT/US, it is referred to as the Controlling Chassis.
  • Page 71: System Configuration - Sv8100

    UNIVERGE SV8100/SV8300 Issue No. 1.5 System Configuration – SV8100 The SV8100 19” chassis provides 104 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 416 ports (320 digital terminals). Through IP connection and use of additional 19”...
  • Page 72: Table 2-3 Sv8100 Maximum System Capacities - Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-3 SV8100 Maximum System Capacities – Chassis shows the maximum number of chassis and related equipment that can be installed in a system. Table 2-3 SV8100 Maximum System Capacities – Chassis 19” 19” 19”...
  • Page 73 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-4 SV8100 Maximum System Capacities – Blades 19” 19” 19” Chassis Hardware Chassis Chassis without Networked with CPU Comments Chassis Number of Slot(s) for Interface 5 Slots 6 Slots 23 Slots Package Common Control Blades: CD-CP00-AU/EU/OT/US –...
  • Page 74 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-4 SV8100 Maximum System Capacities – Blades (Continued) 19” 19” 19” Chassis Hardware Chassis Chassis without Networked with CPU Comments Chassis Number of Slot(s) for Interface 5 Slots 6 Slots 23 Slots Package Trunk Blades: CD-2BRIA –...
  • Page 75: Licensing

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-5 Daughter Board Combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the CD-LTA can have a PZ-2BRIA or the PZ-4COTG daughter board mounted.
  • Page 76 This License is NOT REQUIRED to support the CCISOIP Trunking Feature. LK-SYS-IP-TERMINAL-1-LIC NEC SIP Client - One license One NEC SIP Client - supports NEC MLT SIP Terminal and/or NEC Softphone (SP310). LK-SYS-IP-TERMINAL-4-LIC NEC SIP Client - Four license Four NEC SIP Client - supports NEC MLT SIP Terminal and/or NEC Softphone (SP310).
  • Page 77 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-6 System Licenses (Continued) License Function Description Voice Mail and Unified Messaging: LKS-VM-VRS2-LIC VRS Port - Two license Two Port License VRS – supports general message, personal greeting, Automated Attendant, ACD messages. Supports a maximum 16 dynamic VRS ports and/or eight dynamic InMail ports.
  • Page 78 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-6 System Licenses (Continued) License Function Description LKS-UMS-CLIENT16-LIC UM8000 Mail View App 16 Client View App Session UMS8000 Mail. Supports client, Session - 16 license View Mail, View Call Plus, VMM (outlook), VML (Lotus Notes), VMG (GroupWise) and Web Mailbox Manager.
  • Page 79 (SP310) Client - One license in conjunction with NEC Desktop Suite (Assistant, Attendant, SOFTPHONE1-LIC SP310) Stock No. 4421015 SV8100 Application CD. The NEC Softphone SP310 requires a NEC SIP Client License stock number 670716 LK-SYS-IP-TERMINAL-1-LIC. LKS-DESKTOP SUITE- Desktop Suite Soft Phone...
  • Page 80: Table 2-7 Board Power Factor

    OWER ASED ALCULATOR HART ECTION The UNIVERGE SV8100 system uses two types of power factors. For a single chassis chart refer to Table 2-7 Board Power Factor. For the maximum number of specific blades per package, see Table 2-8 Maximum Number of Package Installed.
  • Page 81: Table 2-10 Ip Terminal Power Chart

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-9 Terminal Power Factor Terminal Power Factor 19 inch Chassis =<80 Item Power Factor DTL-24D-1( ) TEL DTL-8LD-1( ) TEL BHA-L( ) UNIT ADA-L( ) UNIT APR-L( ) UNIT BCH-L( ) (BK) UNIT PSA-L( )
  • Page 82: System Requirements And Specifications

    Issue No. 1.5 UNIVERGE SV8100/SV8300 YSTEM EQUIREMENTS AND PECIFICATIONS ECTION Cabling This section provides cabling requirements and specifications for various equipment used in the SV8100 system. Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the...
  • Page 83 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-13 DT700 Series Loop Resistance and Cable Length Terminal or Adapter Ethernet Cable ITL-2E-1( ) (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-6DE-1( ) (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-8LD-1( ) (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m)
  • Page 84: Power Requirements

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Power Requirements A dedicated 50 Hz circuit located within seven feet of the chassis is 240VAC required. A separate dedicated outlet for each chassis should be installed. Double Pole/Neutral Fusing (power supply fuses are located at both the L and N side).
  • Page 85: Power Supply Consumption

    UNIVERGE SV8100/SV8300 Issue No. 1.5 A dedicated outlet, separately fused and grounded for each chassis should be installed. Double Pole/Neutral Fusing (power supply fuses are located at both the L and N side). 6.2.2 Power Supply Consumption Table 2-17 Power Consumption...
  • Page 86: Outside Line Types

    Operating Humidity: 20 ~ 95% RH (non-condensing) Recommended Long Term Humidity: 10 ~ 95% RH Outside Line Types The following outside lines can be used with the UNIVERGE SV8100/SV8300 system. 2-wire, Loop Start or Ground Start Trunks 2-wire, 2-way DID Lines (Dial Pulse or DTMF) DID feature is not available for Europe and Australia market.
  • Page 87: Network

    Network Time Division Multiplexing (TDM) allows transmission of data and voice simultaneously over one communications medium. The specifications that the UNIVERGE SV8100/SV8300 system uses for switching, clock, data bus, and timeframe are shown below. TDM Switching: PCM (µ Law/A-Law) TDM Clock: 2.048 MHz TDM Data Bus: 8 bit TDM Timeframe: 125 µs.
  • Page 88: Dialing Specifications

    Dial Pulse Address Signaling uses dial pulses (regular momentary interruptions) to signal the equipment. The following Dial Pulse specifications are used in the UNIVERGE SV8100/SV8300 system. Pulse Rate: 10 ± 0.5 pps/20 ± 1.0 pps Percent Break: 60 ± 1.5% Interdigit Interval: 0 pps/20 pps 770 ms.
  • Page 89: External Equipment Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Duration of Dual Frequency Signal: 110 ms. default/60 ms. minimum Interdigital Time: 140 ms. default/45 ms. minimum Nominal High Group Frequencies (Hz) 1209 1336 1477 Nominal Low Group Frequencies (Hz) 6.6.3 External Equipment Connection Door Phone or TV Door Phone...
  • Page 90: Pc Connection

    6.6.9 Relay Contact All Relay Contact Ratings: 500 mA, 24Vdc Battery Backup The UNIVERGE SV8100/SV8300 system has battery backup functions for system backup and for memory backup. 6.7.1 System Backup (Optional) During a power failure, the system can be backed up using the CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE BATTs for a backup time ranging from 45~180 minutes.
  • Page 91: Weights And Dimensions

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Weights and Dimensions Table 2-18 SV8100 Weights and Dimensions on page 2-25 shows the shipping weight, height, width and depth of each SV8100 digital multiline terminal, IP term multiline terminal, D , Series i multiline terminal, chassis, assorted blades and adapters.
  • Page 92 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 2-18 SV8100 Weights and Dimensions (Continued) Shipping Unit Height Width Depth Weight CD-4LCA 5.99 oz 0.98 in 9.45 in 7.68 in (0.17 kg) (25 mm) (240 mm) (195 mm) PZ-4LCA 3.10 oz 0.60 in 9.45 in...
  • Page 93 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 2-18 SV8100 Weights and Dimensions (Continued) Shipping Unit Height Width Depth Weight Digital Multiline Terminal DTL-2E-1( ) (BK) TEL 35.27 oz 4.41 in 7.05 in 8.86 in (1.0 kg) (112 mm) (179 mm) (225 mm) DTL-6DE-1( ) (BK) TEL 38.8 oz...
  • Page 94: Tone Patterns

    Tone Patterns Table 2-19 Tone Patterns lists the frequency and the pattern for the tones. Tones are used to inform UNIVERGE SV8100/SV8300 station users of system functions such as dial tone, busy tone, or ringback tone. Table 2-19 Tone Patterns...
  • Page 95: Multiline Terminal Led Flash Patterns

    Issue No. 1.5 6.8.2 Multiline Terminal LED Flash Patterns The UNIVERGE SV8100/SV8300 system has several colored LEDs installed. Green is used primarily for I-Use conditions and for outside calls. Red is used primarily for Other Use conditions and internal calls.
  • Page 96: Traffic Capacity

    Issue No. 1.5 UNIVERGE SV8100/SV8300 RAFFIC APACITY ECTION Table 2-21 Traffic Capacity provides information about the traffic capacity for the basic system package and expanded system package. Table 2-21 Traffic Capacity Basic System Expanded System Traffic Capacity Package Package Traffic Capacity...
  • Page 97: Chapter 3 Sv8300 System Specifications

    SV8300 System Specifications ENERAL NFORMATION ECTION This chapter provides detailed specifications for the SV8300 system technician. The technician should review this information carefully before installing the system. YSTEM LOCK IAGRAM ECTION Figure 3-1 SV8300 System Block Diagram shows the Blades that can be installed in the chassis and the number of channels supported when the Blade is installed.
  • Page 98 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 3-1 List of Abbreviations (Continued) Abbreviation Description Device Registration Server (on CPU) Direct Station Selection Console Digital Trunk Interface Digital Tone Generator (on CPU) ETHERNET Ethernet Port (on CPU) EX IN/EX OUT Unit Synchronization Port (IN/OUT) (on CPU)
  • Page 99 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 3-1 List of Abbreviations (Continued) Abbreviation Description RS1/RS2 Serial Port (on CPU) Single Line Telephone SMDR Station Message Detail Recording SWHUB Power over Ethernet Hub TDSW Time Division Switch (on CPU) VM00 In-Skin UMS Blade...
  • Page 100 Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 3-1 SV8300 System Block Diagram 3 - 4 SV8300 System Specifications...
  • Page 101: Maximum System Capacities

    UNIVERGE SV8100/SV8300 Issue No. 1.5 AXIMUM YSTEM APACITIES ECTION The CD-CP00-AU/EU/OT/US is a single slot, 19” chassis holding the CC-CP00 blade and one PSU. The CD-CP00-AU/EU/OT/US can be expanded by adding a maximum of three additional CHS2U-AU/EU/OT/US chassis (referred to as a Unit), increasing the capacity of the system to meet the customer’s business needs.
  • Page 102 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 3-2 SV8300 Maximum System Capacity (Continued) 1 Unit Units Units Units System Maximum Item Remote Standalone Unit Central Office Trunk Tie Line Trunk E&M BRI Trunk Physical PRI (23B+D) Trunk Port PRI (30B+D) Trunk...
  • Page 103: System Configuration - Sv8300

    UNIVERGE SV8100/SV8300 Issue No. 1.5 System Configuration – SV8300 The SV8300 consists of a CD-CP00-AU/EU/OT/US chassis and CHS2U-AU/ EU/OT/US chassis depending on the system configuration. The CC-CP00 blade in the CD-CP00-AU/EU/OT/US chassis can control a maximum of three CHS2U-AU/EU/OT/US Chassis, collectively called a UNIT. The SV8300 can be configured for a maximum of four UNITs.
  • Page 104: Table 3-3 Maximum System Capacity - Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 SV8300 (Main Unit) SV8300 SV8300 SV8300 (Remote Unit 1) (Remote Unit N) (Remote Unit 2) Maximum of 46 Remote Unit per System Maximum of 2048 ports per System (Maximum of 324 ports per Remote Unit) Figure 3-4 System Configuration Example (Remote Unit Over IP System) Table 3-3 Maximum System Capacity –...
  • Page 105: Table 3-4 Sv8300 Maximum System Capacities - Blades

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 3-3 Maximum System Capacity – Chassis (Continued) 1 Unit 2 Units 3 Units 4 Units System Maximum Equipment Remote 2Ux1 2Ux2 2Ux3 2Ux6 2Ux9 2Ux12 Standalone Unit 45 minutes LARGE backup BATT BOX 3 hours backup...
  • Page 106 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 3-4 SV8300 Maximum System Capacities – Blades 1 Unit 2 Units 3 Units 4 Units System Maximum Equipment Remote 2Ux 6 2Ux 9 2Ux 12 Standalone Unit Common Control Blades: CC-CP00 PZ-64IPLA PZ-128IPLA PZ-VM21...
  • Page 107: Table 3-5 Daughter Board Combinations

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 3-5 Daughter Board Combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the CD-4COTB can have a PZ-4COTF daughter board mounted.
  • Page 108: Table 3-7 Maximum System Capacity - Optional Equipment

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 3-7 Maximum System Capacity – Optional Equipment shows the maximum number of optional equipment that can be installed in a system. Table 3-7 Maximum System Capacity – Optional Equipment 1 Unit System Maximum Units...
  • Page 109: Licensing

    UNIVERGE SV8100/SV8300 Issue No. 1.5 ICENSING ECTION Table 3-9 System Licenses provides a list of the licensing available with the system. Table 3-9 System Licenses Category License Description System LS-SYS-PORT CAPACITY-LIC Port Capacity LS-SYS-IPPAD16-LIC VoIP Channels (VoIPDB) LS-SYS-R1-LIC System Version License R1...
  • Page 110: Table 3-10 Blade Power Factor

    Issue No. 1.5 UNIVERGE SV8100/SV8300 OWER ASED ALCULATOR HART ECTION The SV8300 system used two types of power factors. For a single chassis chart refer Table 3-10 Blade Power Factor. Refer to Table 3-11 Terminal Power Factor below, for the Terminal/Adapter power chart.
  • Page 111: System Requirements And Specifications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 3-11 Terminal Power Factor (Continued) Terminal Power Factor Total = < 80 per 19 inch Chassis Item Power Factor term DSS Console Series i Option Analog Port Adapter without Ringer (APA) Analog Port Adapter with...
  • Page 112 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 3-12 Cable Length of Terminals Cable Cable Length between Terminal Remarks SV8300 and Terminal Kind of Cable Pair term Twisted Pair Cable 1-pair 1312 ft (400m) with 22 AWG – DT300 Series/ Series i 1968 ft (600m) with 24 AWG –...
  • Page 113: Power Requirements

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 3-13 Cable Length of Optional Equipment (Continued) Cable Cable Length between Terminal Remarks SV8300 and Terminal Kind of Cable Pair PGD(2)-U( ) ADP Twisted Pair Cable 1-pair 1968 ft (600m) with 22 AWG 2625 ft (800m) with 24 AWG –...
  • Page 114 Issue No. 1.5 UNIVERGE SV8100/SV8300 With input voltage of 120 VAC and with full load conditions: AC Input I: Controlling Chassis=2.19A, Expansion Chassis=2.19A, total 4.38A VA @ 120V: Controlling Chassis=263 VA, Expansion Chassis= 263 VA, total 526 VA KWh @ AC Input I x 120V/1000: Controlling Chassis=0.263 KWh, Expansion Chassis=0.263 KWh, total 0.526...
  • Page 115: Power Supply Consumption

    UNIVERGE SV8100/SV8300 Issue No. 1.5 6.2.2 Power Supply Consumption AC 100 V power supply: Table 3-14 Power Consumption Maximum Watts Used Watts Used Chassis (Idle) (Maximum) Current Controlling Chassis 0.7A Controlling Chassis + Expansion 2.89A 136W 175W Chassis Controlling Chassis + 2 Expansion 5.08A...
  • Page 116: Outside Line Types

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Humidity: 10 ~ 90% RH (non-condensing) Recommended Long Term Humidity: 10 ~ 90% RH Blades – CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA, CD-4COTB, D-4COTC, D-4COTE, PZ-4COTF, PZ-4COTG, CD-PRTA, CD-CCTA Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C) Recommended Long Term Temperature: -4°F ~ +140°F...
  • Page 117: Network

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Data Transmission Rates: Between CD-8DLCA and multiline terminal: 184K bps (voice and signaling) Scanning Time for each multiline terminal: 32 ms. 6.5.2 Network Time Division Multiplexing (TDM) allows transmission of data and voice simultaneously over one communications medium. The specifications that the SV8300 system uses for switching, clock, data bus, and timeframe are shown below.
  • Page 118: Series I Terminals

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Single Line Telephone Nominal Current: 25 mA Ring Signal: 56 Vac RMS @ 20 Hz AP(A)-R Unit Nominal Current: 30 mA AP(R)-R Unit Nominal Current: 30 mA Ring Signal: 56 Vac RMS @ 20 Hz 6.5.5...
  • Page 119 UNIVERGE SV8100/SV8300 Issue No. 1.5 Frequency Deviation: Less than ±1.5% Signal Level: Nominal level per frequency: -6 ~ -4 dBm Minimum level per frequency Low Group: -10 dBm High Group: -8 dBm Maximum level per frequency: 0 dBm Rise Time: Within 5 ms.
  • Page 120 Issue No. 1.5 UNIVERGE SV8100/SV8300 6.6.5 External Paging (Audio) Output Power: –10 dBm Signal Level Ω Output Impedance: 600 Relay Contact Rating: 500 mA, 24 Vdc 6.6.6 External Tone Ringer/Night Chime Output Output Level: –10 dBm Ω Output Impedance: 600 Relay Contact Rating: 500 mA, 24 Vdc 6.6.7...
  • Page 121: Weights

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Weights and Dimensions Table 3-16 SV8300 Weights shows the weight of main equipment for SV8300. Figure 3-6 SV8300 Chassis Dimensions shows the dimension of main equipment for SV8300. 6.8.1 Weights Table 3-16 SV8300 Weights Equipment...
  • Page 122: Dimensions

    Issue No. 1.5 UNIVERGE SV8100/SV8300 6.8.2 Dimensions Controlling Chassis 43 mm (1.7 inch) Expansion Chassis 88 mm (3.5 inch) Figure 3-6 SV8300 Chassis Dimensions UNIT (Controlling Chassis + Expansion Chassis x 3) BASE UNIT Figure 3-7 SV8300 Chassis Dimensions (Controlling and Three Expansion)
  • Page 123: Audible And Visual Indication

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Audible and Visual Indication 6.9.1 Lamp Display Table 3-17 Lamp Display on page 3-27 shows the state of the multiline terminal. Table 3-17 Lamp Display Display State Cycle (second) Turning off Slow blinking 0.25 Blinking 0.25...
  • Page 124: Tone Patterns

    Issue No. 1.5 UNIVERGE SV8100/SV8300 6.9.2 Tone Patterns lists the frequency and the pattern for the tones. Tones are used to inform SV8300 station users of system functions such as dial tone, busy tone, or ringback tone. on page 3-28 lists the frequency and the pattern for the tones.
  • Page 125: Multiline Terminal Led Flash Patterns

    UNIVERGE SV8100/SV8300 Issue No. 1.5 6.9.3 Multiline Terminal LED Flash Patterns The SV8300 system has 2-color LEDs. Green is used primarily for I-Use conditions and for outside calls. Red is used primarily for Other Use conditions and internal calls. Refer to...
  • Page 126: Traffic Capacity

    Issue No. 1.5 UNIVERGE SV8100/SV8300 RAFFIC APACITY ECTION Table 3-20 Traffic Capacity provides information about the traffic capacity for the basic system package and expanded system package. Table 3-20 Traffic Capacity Traffic Capacity (CC-CP00) System Max. 12000 BHCA Traffic Conditions: 2n+m <...
  • Page 127: Chapter 4 Installing The Sv8100 Chassis

    Installing the SV8100 Chassis ENERAL NFORMATION ECTION This chapter contains information to help the technician install the chassis for the SV8100 system. The technician should be familiar with this section before installing any equipment. MDF/IDF C REPARATION AND ONSTRUCTION ECTION Pre-installation planning is essential.
  • Page 128: Surveying The Customer Site

    Chassis are normally rack mounted to protect against accident or flooding. The chassis should not be located directly beneath pipes. Leaks or condensation could damage the UNIVERGE SV8100/SV8300 system equipment. The area where the chassis is located must be free of corrosive...
  • Page 129: Selecting A Permanent Mdf Location

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.3.2 Selecting a Permanent MDF Location When selecting a permanent site for the MDF, the technician may encounter some of the following conditions: Limited space is available but must be used. The available space may pose one or more environmental hazards.
  • Page 130: Power Failure Transfer

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The system requires a 3-prong dedicated 240 VAC 50 Hz circuit (NEMA 5-15 receptacle) located within 7 feet of the AC receptacle. Telco should install the RJ21X to the right of the Controlling Chassis. Extension blocks should be installed to the left of the Controlling Chassis.
  • Page 131 UNIVERGE SV8100/SV8300 Issue No. 1.5 NSTALLING THE HASSIS ECTION The CHS2U-AU chassis has six universal blade slots for legacy line/trunk blade (Single Line Telephone Interface, Digital multiline terminal Interface, Central Office Trunk, ISDN PRI Interface, etc.), In-skin Application Blades (In-skin UMS, In-Skin Router, etc.).
  • Page 132: Wall Mounting The 19" Chassis

    This allows secure anchoring of the screws which support the weight of the chassis. Due to chassis weight, NEC recommends only a single CHS2U-AU chassis per wall mount. Upper Surface of Wall Mount Bracket Figure 4-3 Wall Mount Spacing Guide (19”...
  • Page 133: Figure 4-4 Install Wall Mount Brackets With Screws

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Mark and drill the six holes required for a wall installation. Align screw holes in wall mount brackets with drilled holes. Using six screws, secure the two wall mount brackets to the wall. Refer to Figure 4-4 Install Wall Mount Brackets with Screws screw location.
  • Page 134: Figure 4-5 Securing Metal Fittings To Chassis With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using four screws, secure the metal fittings on the Left and Right sides of the 19” chassis. Refer to Figure 4-5 Securing Metal Fittings to Chassis with Screws for screw location. Figure 4-5 Securing Metal Fittings to Chassis with Screws...
  • Page 135: Figure 4-6 Secure Metal Fitting To Upper Wall Mount Bracket With A Screw

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the metal fitting with the upper wall mount bracket. The lower metal fitting will rest against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see...
  • Page 136: Figure 4-7 Secure Metal Fitting To Lower Wall Mount Bracket With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using two screws, secure the metal fitting to the lower wall mount bracket. Refer to Figure 4-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws for screw location. Figure 4-7 Secure Metal Fitting to Lower Wall Mount Bracket with...
  • Page 137: Figure 4-8 Attach Cable Support Bracket To Lower Wall Mount Bracket

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to Figure 4-8 Attach Cable Support Bracket to Lower Wall Mount Bracket). Figure 4-8 Attach Cable Support Bracket to Lower Wall Mount Bracket...
  • Page 138: Figure 4-9 Attachment Locations Of Cable Support Bracket

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The cable support bracket can be installed any of the four corners of the 19” chassis (refer to Figure 4-9 Attachment Locations of Cable Support Bracket). Figure 4-9 Attachment Locations of Cable Support Bracket Connect the ground wire to all chassis. Refer to 3.5.5 Install 19”...
  • Page 139: Floor Mounting The 19" Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Floor Mounting the 19” Chassis The CHS2U-AU controlling and expansion chassis can be mounted on the floor using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT. 3.2.1 CHS2U-AU Chassis Installation Use the template shown in...
  • Page 140: Figure 4-11 Secure Chs Base Unit With Anchor Bolts

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using anchor bolts, secure the CHS BASE UNIT to the floor. Refer to Figure 4-11 Secure CHS BASE UNIT with Anchor Bolts on page 4-14 for screw location.. Figure 4-11 Secure CHS BASE UNIT with Anchor Bolts Install the five rubber feet to the bottom of the chassis.
  • Page 141: Multiple Chs2U-Au Chassis Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Secure the chassis to the CHS BASE UNIT using eight screws supplied with the CHS2U JOINT BRACKET KIT. Figure 4-13 Install CHS2U JOINT BRACKET KIT Connect the ground wire to all chassis. Refer to 3.5.5 Install 19”...
  • Page 142: Figure 4-15 Install Metal Brackets With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using supplied screws in the CHS2U JOINT BRACKET KIT, attach metal brackets to both ends of the 19” chassis and the CHS BASE UNIT. Refer to Figure 4-15 Install Metal Brackets with Screws. Metal Brackets Figure 4-15 Install Metal Brackets with Screws Connect the ground wire to all chassis.
  • Page 143: Stand Mounting The 19" Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Stand Mounting the 19” Chassis A single or multiple chassis can be stand mounted. Controlling and Expansion chassis can be stand mounted using the CHS2U STAND KIT(K) and CHS2U JOINT BRACKET KIT. 3.3.1 CHS2U-AU Chassis Installation...
  • Page 144: Figure 4-17 Secure Chs2U-Au Chassis To Chs2U Stand Kit With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Secure the CHS2U-AU chassis to the assembled CHS2U STAND KIT, see Figure 4-17 Secure CHS2U-AU Chassis to CHS2U STAND KIT with Screws on page 4-18. Expansion Plate Figure 4-17 Secure CHS2U-AU Chassis to CHS2U STAND KIT with Screws...
  • Page 145: Figure 4-18 Secure Stand Mount To Floor With Screws

    Figure 4-18 Secure Stand Mount to Floor with Screws on page 4-19). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. Figure 4-18 Secure Stand Mount to Floor with Screws Connect the ground wire to all chassis.
  • Page 146: Multiple Chs2U-Au Chassis Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.3.2 Multiple CHS2U-AU Chassis Installation Expansion chassis (maximum of three) can be added to the CHS2U STAND KIT and will require an additional CHS2U JOINT BRACKET KIT per chassis. Install the five rubber feet to the bottom of each chassis.
  • Page 147: Figure 4-21 Install Additional Chs2U Joint Bracket Kit

    Figure 4-21 Install Additional CHS2U JOINT BRACKET KIT). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. Connect the ground wire to all chassis. Refer to 3.5.5 Install 19”...
  • Page 148: Rack Mounting The 19" Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Rack Mounting the 19” Chassis A single or multiple chassis can be rack mounted. Controlling and Expansion chassis can be racked mounted by stacking them horizontally. The 19” chassis requires two rack mount brackets per chassis for mounting.
  • Page 149: Figure 4-24 Rack Mount 19" Chs2U-Au

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Repeat for additional chassis mounting. Figure 4-23 Rack Mount Bracket Installed 19” CHS2U-AU Carefully slide the chassis into desired location within the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place.
  • Page 150: Installing The 19" Chassis

    Inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized NEC Sales Representative if you have additional questions. Note that the chassis does not initially contain any blades.
  • Page 151: Installing Expansion Blades In The 19" Chassis (Optional)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the CD-CP00-AU blade with the Slot 1 guides of the Controlling Chassis. Figure 4-25 19” Controlling Chassis – Guides Slot 1 Slide the CD-CP00-AU blade into the chassis until resistance (back plane) is felt.
  • Page 152: Table 4-3 Pz-Bs10/Pz-Bs11 Connector Pin-Out

    The EXIFU cable connects the Controlling Chassis and its EXIFU-B1 interface to the second, third, and fourth EXIFU-E1 interface. Use only the CAT 5 cables provided by NEC to make the connections between the Controlling and Expansion Chassis. The PZ-BS10 provides:...
  • Page 153: Figure 4-28 Pz-Bs10 Expansion Bay In Controlling Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Locate the door positioned on the left end (expansion bay) of the Controlling Chassis. Expansion Bay Figure 4-28 PZ-BS10 Expansion Bay in Controlling Chassis From the left side of the chassis, pull cover outward to expose the expansion bay.
  • Page 154: Figure 4-30 Pz-Bs10 Blade Guides

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Align the PZ-BS10 blade with the guides located in the expansion bay. Figure 4-30 PZ-BS10 Blade Guides Figure 4-31 PZ-BS10 Components 4 - 28 Installing the SV8100 Chassis...
  • Page 155: Figure 4-32 Installing Pz-Bs10 Blade In Expansion Bay

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Slide the PZ-BS10 blade into the chassis until resistance (back plane) is felt. Figure 4-32 Installing PZ-BS10 Blade in Expansion Bay Gently push until the blade seats and install the supplied retaining screw. Align the door tabs with hinges and reattach the cover.
  • Page 156: Figure 4-34 Pz-Bs10 Installed (Cover Closed)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Close the PZ-BS10 cover. Figure 4-34 PZ-BS10 Installed (Cover Closed) 3.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U-AU Expansion Chassis For the Expansion Chassis to function, the PZ-BS10 blade must be installed in Controlling Chassis.
  • Page 157: Figure 4-36 Open Expansion Chassis Cover

    UNIVERGE SV8100/SV8300 Issue No. 1.5 From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 4-36 Open Expansion Chassis Cover Pull the cover toward you to remove. Cover must be removed to install PZ-BS11 blade.
  • Page 158: Figure 4-38 Installing Pz-Bs11 Blade In Expansion Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Slide the PZ-BS11 blade into the chassis until resistance (back plane) is felt. Figure 4-38 Installing PZ-BS11 Blade in Expansion Chassis Gently push until the blade seats and install the supplied retaining screw. Align the door tabs with hinges and reattach the cover.
  • Page 159: Figure 4-40 Pz-Bs11 Installed (Cover Closed)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Close the PZ-BS11 blade cover. Figure 4-40 PZ-BS11 Installed (Cover Closed) 3.5.4.4 Connect the Controlling and Expansion Chassis Installment of the PZ-BS10 blade and PZ-BS11 blade(s) must be completed prior to installation of the provided (Cat 5) expansion cabling.
  • Page 160: Install 19" Chassis Grounding

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using the NEC provided CAT5 straight-through cable(s), attach one end to each Expansion Chassis CN2 connector on the PZ-BS11 blade (see Figure 4-42 System Expansion Cabling on page 4-34. Attach the opposite end to the CN2, CN3 or CN4 connector on the PZ-BS10 of the Controlling Chassis.
  • Page 161: Install 19" Grounding On Multiple Chassis (Optional)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Ground each chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis to an electrical service ground (such as a cold water pipe). CHS2U-AU FG Lug Figure 4-43 Chassis Grounding Lug 3.5.6...
  • Page 162: Install Ac Power Cords

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.5.7 Install AC Power Cords Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis. CHS2U-AU AC Inlet Figure 4-45 Install the AC Power Cord 3.5.8...
  • Page 163: Battery Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 ATTERY ONNECTION ECTION There are two types of battery connection to provide battery life in the event of a power failure, the internal battery and an external battery with CHS LARGE BATT BOX. Installing the Internal Batteries An internal battery source using two batteries can be installed using the CHS2U BATT MTG KIT (mounting kit) and CHS2U BATT CA INT (internal cabling).
  • Page 164: Figure 4-48 Removing Access Panel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove access panel containing the fan. Refer to Figure 4-48 Removing Access Panel Figure 4-49 Access Panel Removed. Figure 4-48 Removing Access Panel Figure 4-49 Access Panel Removed 4 - 38 Installing the SV8100 Chassis...
  • Page 165: Figure 4-50 Secure Cable In Support Bracket

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using tie wraps, secure CHS2U BATT CA INT in cable guide bracket (refer to Figure 4-50 Secure Cable in Support Bracket). Figure 4-50 Secure Cable in Support Bracket With supplied screw, install cable guide in chassis (refer to...
  • Page 166: Figure 4-52 Installing Two Batteries

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT MTG KIT (refer to Figure 4-52 Installing Two Batteries). The first battery must be installed on the left side, then slid to the right due to an installation tab on the mounting kit.
  • Page 167: Figure 4-54 Connecting Chs2U Batt Ca Int

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect CHS2U BATT CA INT to battery connector (refer to Figure 4-54 Connecting CHS2U BATT CA INT). Figure 4-54 Connecting CHS2U BATT CA INT Install CHS2U BATT MTG KIT into CHS2U-AU chassis and tighten the...
  • Page 168: Installing The External Batteries

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Reinstall access panel containing the fan and secure with supplied screw (refer to Figure 4-56 Installing the Access Panel). Figure 4-56 Installing the Access Panel Connect grounding and AC power cable. Installing the External Batteries An optional (locally procured), external battery source can be used to provide power in the event of a power failure.
  • Page 169: Floor Mounting The Chs Large Batt Box

    UNIVERGE SV8100/SV8300 Issue No. 1.5 4.2.1 Floor Mounting the CHS LARGE BATT BOX Because of injury from falling equipment, wall mounting the CHS LARGE BATT BOX is not recommended. Mounting the CHS LARGE BATT BOX directly on the floor is not recommended.
  • Page 170: Battery Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Align and install the CHS LARGE BATT BOX on top of the CHS BASE UNIT. Refer to Figure 4-58 Installing the CHS LARGE BATT BOX using the CHS2U JOINT BRACKET KIT on page 4-44. Figure 4-58 Installing the CHS LARGE BATT BOX using the CHS2U JOINT BRACKET KIT Secure the CHS LARGE BATT BOX to the CHS BASE UNIT using the CHS2U JOINT BRACKET KIT.
  • Page 171: Figure 4-60 Removing Battery Tray Suppressor

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Remove two screws from front of Battery Tray Suppressor. Refer to Figure 4-60 Removing Battery Tray Suppressor. Figure 4-60 Removing Battery Tray Suppressor Slide Battery Tray Suppressor outward to remove. Slide Battery Tray(s) out of CHS LARGE BATT BOX.
  • Page 172: Figure 4-62 Removing Battery Tray Bracket

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove two screws and remove the Battery Tray Bracket. Refer Figure 4-62 Removing Battery Tray Bracket. Figure 4-62 Removing Battery Tray Bracket Refer to Figure 4-63 Battery Cable Connection Guide connection of battery cable to battery terminals. Repeat for additional battery connection.
  • Page 173: Figure 4-64 Installing Battery Connection Cable

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using two screws, install the Battery Tray Bracket. Refer to Figure 4-62 Removing Battery Tray Bracket on page 4-46. Figure 4-64 Installing Battery Connection Cable Insert Battery Connection Cable into cable guides. Refer to Figure 4-64 Installing Battery Connection Cable on page 4-47.
  • Page 174: Chs Large Batt Box To Chs2U-Au Connection

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the Battery Connection Cable(s) into the Fuse Unit. Refer Figure 4-65 Connecting Battery Cables on page 4-48. Figure 4-65 Connecting Battery Cables Insert tabs on cover into holes on CHS LARGE BATT BOX. Slide the cover left until seated and tighten the screw.
  • Page 175: Figure 4-67 Removing Fan Access Panel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Remove fan access panel from rear of CHS2U-AU chassis. Refer to Figure 4-67 Removing Fan Access Panel. Figure 4-67 Removing Fan Access Panel Connect one end of Battery Connection Cable to Battery Connector on rear of Basic and Expansion chassis.
  • Page 176: Figure 4-69 Single Chs Large Batt Box Connection

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connect other end of cable to Battery Connector on rear of CHS LARGE BATT BOX chassis. Refer to Figure 4-69 Single CHS LARGE BATT BOX Connection Figure 4-70 Dual CHS LARGE BATT BOX Connection. Basic...
  • Page 177: Chs Large Batt Box Fuse Replacement

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Insert the access panel tab into the rear of the CHS1U-AU chassis running the Battery Connection Cable through the cutout. Secure panel with the retaining screw. Refer to Figure 4-71 Install the Fan Access Panel.
  • Page 178: Figure 4-73 Removing Battery Tray Suppressor

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove two screws from front of Battery Tray Suppressor. Refer to Figure 4-73 Removing Battery Tray Suppressor. Figure 4-73 Removing Battery Tray Suppressor Slide Battery Tray Suppressor outward to remove. Disconnect the Battery Connection Cables from the Fuse Unit.
  • Page 179: Figure 4-65 Connecting Battery Cables

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 4-75 CHS LARGE BATT BOX Fuse Unit Slide the Fuse Unit into the and tighten the two screws (refer to Figure 4-74 Disconnecting Battery Cables on page 4-52). Plug the Battery Connection Cables into the Fuse Unit. Refer to Figure 4-76 Connecting Battery Cables on page 4-53.
  • Page 180: Power Supply

    Figure 4-77 Installing Cover Battery OWER UPPLY ECTION Do not attempt to replace the power supply. The MPS7101 is not a field replaceable part. If the power supply fails contact NEC. EMOVE AND NSTALL OOLING ECTION If required, the cooling fan installed in the CHS2U-AU chassis can be removed and replaced.
  • Page 181: Figure 4-78 19" Chassis Access Panel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Loosen retaining screw from chassis access panel. Retaining Screw Figure 4-78 19” Chassis Access Panel Swing access panel outward and unplug fan power cable. See Figure 4-79 Opening Chassis Access Panel (19” Chassis). Fan Power Cable Plug Figure 4-79 Opening Chassis Access Panel (19”...
  • Page 182: Install Cooling Fan

    Issue No. 1.5 UNIVERGE SV8100/SV8300 6.1.2 Install Cooling Fan Align replacement fan with holes and secure with two screws (refer to Figure 4-80 Chassis Access Panel Removed (19” Chassis) on page 4-55. Install cabling into retention clips (refer to Figure 4-80 Chassis Access Panel Removed (19”...
  • Page 183 UNIVERGE SV8100/SV8300 Issue No. 1.5 - - NOTES - - System Hardware Manual 4 - 57...
  • Page 184 Issue No. 1.5 UNIVERGE SV8100/SV8300 - - NOTES - - 4 - 58 Installing the SV8100 Chassis...
  • Page 185: General Information

    Installing the SV8300 Chassis ENERAL NFORMATION ECTION This chapter contains information to help the technician install the chassis for the SV8300 system. The technician should be familiar with this section before installing any equipment. MDF/IDF C REPARATION AND ONSTRUCTION ECTION Pre-installation planning is essential.
  • Page 186: Surveying The Customer Site

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Although it is recommended to install the blades with the system power off, all blades can be installed hot, except for the following: CC-CP00 PZ-BS10 and PZ-BS11 PZ-64IPLA and PZ-128IPLA PZ-VM21 Surveying the Customer Site...
  • Page 187: Selecting A Permanent Mdf Location

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.3.2 Selecting a Permanent MDF Location When selecting a permanent site for the MDF, the technician may encounter some of the following conditions: Limited space is available but must be used. The available space may pose one or more environmental hazards.
  • Page 188: Power Failure Transfer

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The system requires a 3-prong dedicated 110 VAC 60 Hz circuit (NEMA 5-15 receptacle) located within 7 feet of the AC receptacle. Telco should install the RJ21X to the right of the Controlling Chassis. Extension blocks should be installed to the left of the Controlling Chassis.
  • Page 189: Installing The Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 NSTALLING THE HASSIS ECTION There are two types of chassis, the 19” CHS1U-AU chassis and the 19” CHS2U-AU chassis. The CHS1U-AU chassis mounts the CC-CP00 blade, PZ-BS10 for the CHS2U-AU chassis expansion, PZ-PW146(1U) Power Supply and Cooling FAN.
  • Page 190: Figure 5-3 Chs2U-Us Chassis (Front View)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Universal Slot for Legacy Line/Trunk blades and Application blades (six slots) Slot for PZ-BS10/PZ-BS11 blade – Connection with CHS2U-AU Power Supply Unit Figure 5-3 CHS2U-US Chassis (Front View) Internal Battery Fan Unit (inside of cover)
  • Page 191: Wall Mounting The 19" Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Wall Mounting the 19” Chassis When wall mounting the chassis, ensure the wall can support the weight of the chassis (31 lbs per system chassis including blades, cords, power supply, etc.). The chassis is secured to the wall with a wall mount bracket. Ensure that enough space is available to allow the installation of additional expansion chassis.
  • Page 192 Issue No. 1.5 UNIVERGE SV8100/SV8300 Upper Surface of Wall Mount Figure 5-5 Wall Mount Spacing Guide (19” Chassis) 5 - 8 Installing the SV8300 Chassis...
  • Page 193: Figure 5-6 Drilling Instructions For Anchor Bolt

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Mark and drill the six holes required for a wall installation. Drilling: Make a preliminary hole in the concrete, using a drill bit for small- diameter holes. Drill a hole in the concrete with a drill suitable for a plug bolt a little deeper than the plug bolt length.
  • Page 194: Figure 5-7 Securing Wall Mount Brackets With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using six screws, secure the two wall mount brackets to the wall. Refer to Figure 5-7 Securing Wall Mount Brackets with Screws for screw location. Figure 5-7 Securing Wall Mount Brackets with Screws 5 - 10...
  • Page 195: Figure 5-8 Installing Metal Fittings With Screws

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using four screws, secure the metal fittings on the Left and Right sides of the 19” chassis. Refer to Figure 5-8 Installing Metal Fittings with Screws for screw location. Figure 5-8 Installing Metal Fittings with Screws Install five rubber feet on bottom of CHS1U-AU chassis.
  • Page 196: Figure 5-9 Install Joint Brackets With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Align CHS1U-AU and CHS2U-AU chassis. Secure the two chassis together with a joint bracket and four screws on both sides of the chassis. Refer to Figure 5-9 Install Joint Brackets with Screws for bracket location.
  • Page 197: Figure 5-10 Secure Metal Fitting To Upper Wall Mount Bracket With A Screw

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the metal fitting with the upper wall mount bracket. The lower metal fitting will rest against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see...
  • Page 198: Figure 5-11 Attachment Locations Of Cable Support Bracket

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The cable support bracket can be installed any of the four corners of the 19” chassis (refer to Figure 5-11 Attachment Locations of Cable Support Bracket). Figure 5-11 Attachment Locations of Cable Support Bracket 5 - 14...
  • Page 199: Figure 5-12 Attach Cable Support Bracket To Lower Wall Mount Bracket

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to Figure 5-12 Attach Cable Support Bracket to Lower Wall Mount Bracket). Figure 5-12 Attach Cable Support Bracket to Lower Wall Mount Bracket...
  • Page 200: Figure 5-13 Chs1U-Au And Chs2U-Au Chassis Wall Mounted

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 5-13 CHS1U-AU and CHS2U-AU Chassis Wall Mounted Connect the ground wire to all chassis. Refer to 3.5.7 Install 19” Chassis Grounding on page 5-45 for complete details on grounding the system. Refer to 3.5 Installing the 19” Chassis on page 5-33...
  • Page 201: Floor Mounting The 19" Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Floor Mounting the 19” Chassis The CHS1U-AU controlling and the CHS2U-AU expansion chassis can be mounted on the floor using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT. 3.2.1 CHS1U-AU Chassis Installation Position the CHS BASE UNIT on desired surface and mark four...
  • Page 202: Figure 5-14 Chs Base Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the five rubber feet to the bottom of the chassis. Figure 5-16 Install Rubber Feet (19” Chassis) Position the CHS1U-AU and CHS2U-AU chassis on top of the CHS BASE UNIT. Secure the chassis to the CHS BASE UNIT using screws supplied with the CHS STAND KIT (K).
  • Page 203: Multiple Chs2U-Au Chassis Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.2.2 Multiple CHS2U-AU Chassis Installation Expansion chassis can be secured to the CHS BASE UNIT and will require an additional CHS2U JOINT BRACKET KIT per chassis. Install the five rubber feet to the bottom of each chassis.
  • Page 204: Stand Mounting The 19" Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Stand Mounting the 19” Chassis The SV8300 can be stand mounted. Controlling and Expansion chassis can be stand mounted using the CHS STAND KIT (K), the CHS2U STAND KIT (EXT) and the CHS2U JOINT BRACKET KIT.
  • Page 205: Figure 5-21 Attach Rubber Feet To Chs2U-Us Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install the five rubber feet to the bottom of each chassis. Figure 5-21 Attach Rubber Feet to CHS2U-US Chassis Align CHS1U-AU chassis and CHS2U-AU chassis. Secure the two chassis together with a joint bracket and four screws on top sides of the chassis.
  • Page 206: Figure 5-23 Assemble Stand Mount With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using supplied screws, assemble the CHS STAND KIT (K). Refer to Figure 5-23 Assemble Stand Mount with Screws. Expansi Figure 5-23 Assemble Stand Mount with Screws Using supplied screws, secure the chassis to the assembled CHS STAND KIT (K).
  • Page 207: Figure 5-25 Chs2U-Au/Chs1U-Au Chassis Stand Mount

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align screw holes in floor mount bracket with pre-drilled holes in floor. Using supplied screws, secure the CHS STAND KIT (K) to the floor. Refer to Figure 5-25 CHS2U-AU/CHS1U-AU Chassis Stand Mount on page 5-23.
  • Page 208: Chs1U-Au+Chs2U-Auxn Chassis Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.3.2 CHS1U-AU+CHS2U-AUxN Chassis Installation Expansion chassis (maximum of three) can be added to create a UNIT and will require an additional CHS2U STAND KIT (EXT) per chassis. Using the spacing guide shown below, mark two holes to be drilled.
  • Page 209: Figure 5-27 Attach Rubber Feet To Chs2U-Us Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Mark and drill the two holes required for a floor installation. Install the five rubber feet to the bottom of each chassis. Figure 5-27 Attach Rubber Feet to CHS2U-US Chassis Align CHS1U-AU chassis and CHS2U-AU chassis. Secure the chassis together with a joint bracket on top sides of the chassis.
  • Page 210: Figure 5-29 Assemble Stand Mount With Screws (Chs1U-Au+Chs2U-Aux3 Configuration)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Expansio Screws Figure 5-28 Assemble Stand Mount with Screws (CHS1U-AU+CHS2U-AUx2 Configuration) 3.3.2.2 CHS1U-AU+CHS2U-AUx3 Stand Mount Assembly Using supplied screws, assemble the CHS STAND KIT (K) and CHS2U STAND KIT (EXT). Refer to Figure 5-29 Assemble Stand Mount with Screws...
  • Page 211: Figure 5-30 Attach Stand Mount Brackets To Chassis With Screws (Chs1U-Au+Chs2U-Aux2 Configuration)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using supplied screws, secure the chassis to the assembled CHS STAND KIT (K). Refer to Figure 5-30 Attach Stand Mount Brackets to Chassis with Screws (CHS1U-AU+CHS2U-AUx2 Configuration) for screw location. 3.3.2.3 CHS1U-AU+CHS2U-AUx2 Install Chassis Using supplied screws, secure the chassis to the assembled CHS STAND KIT (K).
  • Page 212: Figure 5-31 Attach Stand Mount Brackets To Chassis With Screws (Chs1U-Au+Chs2U-Aux3 Configuration)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.3.2.4 CHS1U-AU+CHS2U-AUx3 Install Chassis Using supplied screws, secure the chassis to the assembled CHS STAND KIT (K). Refer to Figure 5-31 Attach Stand Mount Brackets to Chassis with Screws (CHS1U-AU+CHS2U-AUx3 Configuration) for screw location. Figure 5-31 Attach Stand Mount Brackets to Chassis with...
  • Page 213: Figure 5-32 Chs1U-Au+Chs2U-Aux2 Chassis Configuration

    Figure 5-33 CHS1U-AU+CHS2U-AUx3 Chassis Configuration on page 5-30. To prevent damage to the 1U/2U chassis due to falling, NEC recommends screws be installed in the floor mount brackets as soon as possible. Figure 5-32 CHS1U-AU+CHS2U-AUx2 Chassis Configuration System Hardware Manual...
  • Page 214: Rack Mounting The 19" Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 5-33 CHS1U-AU+CHS2U-AUx3 Chassis Configuration Connect the ground wire to all chassis. Refer to 3.5.7 Install 19” Chassis Grounding on page 5-45 for complete details on grounding the system. Refer to 3.5 Installing the 19” Chassis on page 5-33 to continue installation of the chassis or, Chapter 5 paragraph 2.3 Installing...
  • Page 215: Figure 5-34 19" Rack Mount Brackets

    UNIVERGE SV8100/SV8300 Issue No. 1.5 CHS1U-AU Rack CHS2U-AU Rack Mount Bracket Mount Bracket Figure 5-34 19” Rack Mount Brackets Line up the Rack Mount Bracket(s) with the pre-drilled holes on each side of the 19” chassis. Secure the brackets to the chassis using the supplied screws. Refer to Figure 5-35 Rack Mount Bracket Installed 19”...
  • Page 216: Figure 5-36 Rack Mount Bracket Installed 19" Chs2U-Au Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 5-36 Rack Mount Bracket Installed 19” CHS2U-AU Chassis Carefully slide the chassis into desired location within the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place. Note that the cabling is run through the front of the rack for ease of access.
  • Page 217: Installing The 19" Chassis

    Inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized NEC Sales Representative if you have additional questions. Note that the chassis does not initially contain any blades.
  • Page 218: Installing The 19" Controlling Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.5.3 Installing the 19” Controlling Chassis Do not remove or install this blade with the power on. Ensure the chassis is powered down. Align the CC-CP00 blade with the slot guide of the Controlling Chassis.
  • Page 219: Installing The 19" Expansion Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.5.4 Installing the 19” Expansion Chassis Do not remove or install this blade with the power on. Ensure the chassis is powered down. Align the blade with the universal slots of the Expansion Chassis. Figure 5-39 19” CHS2U-AU Expansion Chassis Slide the blade into the chassis until resistance (back plane) is felt.
  • Page 220: Table 5-2 Pz-Bs10/Pz-Bs11 Connector Pin-Out

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Use only the CAT 5 cables provided by NEC to make the connections between the Controlling and Expansion Chassis. The PZ-BS10 provides: Communication Processor Interface for data handling through Communication Channel (18 slots maximum) 64 Channels for Telephony Resource (e.g., DTMF Tone Receiver,...
  • Page 221: Figure 5-40 Pz-Bs10 Expansion Bay In Controlling Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Ensure the chassis is powered down. Do not remove or install this blade with the power on. Locate the door positioned on the left end (expansion bay) of the Controlling Chassis (refer to Figure 5-40 PZ-BS10 Expansion Bay in Controlling Chassis).
  • Page 222: Figure 5-42 Pz-Bs10 Blade Guides

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Align the PZ-BS10 blade with the guides located within the expansion bay (refer to Figure 5-42 PZ-BS10 Blade Guides). Guides Figure 5-42 PZ-BS10 Blade Guides Figure 5-43 PZ-BS10 Components Slide the PZ-BS10 blade into the chassis until resistance (back plane) is felt.
  • Page 223: Figure 5-45 Pz-Bs10 Blade Installed

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the door with the hinge and reattach the door. Screw Hinge Figure 5-45 PZ-BS10 Blade Installed Close the PZ-BS10 cover. Figure 5-46 PZ-BS10 Installed (Cover Closed) 3.5.5.3 Install the PZ-BS11 Expansion Blade in the CHS2U-AU...
  • Page 224: Figure 5-48 Open Expansion Chassis Cover

    Issue No. 1.5 UNIVERGE SV8100/SV8300 From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 5-48 Open Expansion Chassis Cover Pull the cover toward you to remove. Cover must be removed to install PZ-BS11 blade.
  • Page 225: Figure 5-50 Installing Pz-Bs11 Blade In Expansion Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Slide the PZ-BS11 blade into the chassis until resistance (back plane) is felt. Figure 5-50 Installing PZ-BS11 Blade in Expansion Chassis Gently push until the blade seats and install the supplied retaining screw. Align the door tabs with hinges and reattach the cover.
  • Page 226: Figure 5-52 Pz-Bs11 Installed (Cover Closed)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Close the PZ-BS11 blade cover. Figure 5-52 PZ-BS11 Installed (Cover Closed) 3.5.5.4 Connect the Controlling and Expansion Chassis Installment of the PZ-BS10 blade and PZ-BS11 blade(s) must be completed prior to installation of the provided...
  • Page 227: Figure 5-54 System Expansion Cabling

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Ensure Controlling and Expansion chassis are powered down. Using the NEC provided CAT5 straight-through cable(s), attach one end to each Expansion Chassis BUS connector on the PZ-BS11 blade (see Figure 5-54 System Expansion Cabling. Attach the opposite end to the BUS connector on the PZ-BS10 of the Controlling Chassis.
  • Page 228: Cable Connection Between Cpu Blades

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.5.6 Cable Connection between CPU Blades When providing multiple-unit configuration, the IP connection between UNITs is required. The UNIT is connected to IP network via the VoIPDB blade on the CPU blade. Refer to Figure 5-55 Cable Connection between CPU Blades.
  • Page 229: Install 19" Chassis Grounding

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.5.7 Install 19” Chassis Grounding From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis. Each chassis (CHS1U-AU or CHS2U-AU) in the system must be grounded separately using the procedure listed below.
  • Page 230: Install Ac Power Cords

    Issue No. 1.5 UNIVERGE SV8100/SV8300 FG Lugs Electrical Service Ground Figure 5-57 19” Chassis Grounding Lug (Multiple-Chassis) 3.5.9 Install AC Power Cords Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis.
  • Page 231: Install Ac Power Cords On Multiple Chassis (Optional)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.5.10 Install AC Power Cords on Multiple Chassis (Optional) Locate the supplied AC power cords and attach to the AC Inlets located on the back of the Controlling and Expansion Chassis. Power Cords to Figure 5-59 Install 19” AC Power Cords (Multiple-Chassis) 3.5.11...
  • Page 232: Figure 5-60 Removing Battery Access Panel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove screws from battery access panel on rear of chassis (see Figure 5-60 Removing Battery Access Panel). Figure 5-60 Removing Battery Access Panel Remove battery access panel and set aside (refer to Figure 5-60 Removing Battery Access Panel).
  • Page 233: Figure 5-62 Securing Cable To Support Bracket

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using tie wraps, secure the CHS1U BATT CA INT BATT to the Cable support bracket (refer to Figure 5-62 Securing Cable to Support Bracket). Figure 5-62 Securing Cable to Support Bracket Using supplied screw, secure Cable Support Bracket to...
  • Page 234: Figure 5-64 Securing Batteries To Battery Tray

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using supplied screws, secure two 12V-0.8AH (locally supplied) batteries to battery tray (see Figure 5-64 Securing Batteries to Battery Tray). Figure 5-64 Securing Batteries to Battery Tray Secure battery bracket to tray (refer to Figure 5-64 Securing Batteries to Battery Tray on page 5-50).
  • Page 235: Figure 5-66 Connect Chs1U Batt Ca Int Batt Cable To Psu Battery Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect CHS1U BATT CA INT BATT to battery connection on PSU (Power Supply Unit) on rear of CHS1U-AU (refer to Figure 5-66 Connect CHS1U BATT CA INT BATT Cable to PSU Battery Connection). Figure 5-66 Connect CHS1U BATT CA INT BATT Cable to PSU Battery Connection...
  • Page 236: Install Internal Batteries Chs2U-Au Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Insert the access panel tab into the slot on the rear of the CHS1U-AU chassis (see Figure 5-68 Re-Install Fan Access Panel). Figure 5-68 Re-Install Fan Access Panel Secure panel with the retaining screw (refer to...
  • Page 237: Figure 5-70 Removing Access Panel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Remove access panel containing the fan. Refer to Figure 5-70 Removing Access Panel. Figure 5-70 Removing Access Panel Using tie wraps, secure CHS2U BATT CA INT in cable guide bracket (refer to Figure 5-71 Secure Cable in Support Bracket).
  • Page 238: Figure 5-72 Installing Cable Support Guide

    Issue No. 1.5 UNIVERGE SV8100/SV8300 With supplied screw, install cable guide in chassis (refer to Figure 5-72 Installing Cable Support Guide). Figure 5-72 Installing Cable Support Guide Install two batteries (12V-2.3AH) into the CHS2U BATT MTG KIT (refer to Figure 5-73 Installing Two Batteries).
  • Page 239: Figure 5-74 Installing Battery Cable

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect the provided battery cables to the batteries (refer to Figure 5-74 Installing Battery Cable). Figure 5-74 Installing Battery Cable Connect CHS2U BATT CA INT to battery connector (refer to Figure 5-75 Connecting CHS2U BATT CA INT).
  • Page 240: Figure 5-76 Installing Battery Tray Into Chs2U-Au Chassis

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install CHS2U BATT MTG KIT into CHS2U-AU chassis (see Figure 5-76 Installing Battery Tray into CHS2U-AU Chassis). Figure 5-76 Installing Battery Tray into CHS2U-AU Chassis Tighten the retaining screws (refer to Figure 5-76 Installing Battery Tray into CHS2U-AU Chassis).
  • Page 241: Install External Batteries (Without Chs Large Batt Box)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install External Batteries (without CHS LARGE BATT BOX) An external battery source can be used to provide longer battery life in the event of a power failure. Remove fan access panel from rear of CHS1U-AU chassis (refer to Figure 5-78 Removing Fan Access Panel CHS1U-AU).
  • Page 242: Figure 5-80 External Battery Box (1U+2Ux1 Configuration) - Two Batteries

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connect locally supplied external batteries and CHS2U BATT CA EXT-A (see Figure 5-80 External Battery Box (1U+2Ux1 Configuration) – Two Batteries) for two batteries and (see Figure 5-81 External Battery Box (1U+2Ux2/1U=2Ux3 Configuration) – Four Batteries) for four batteries.
  • Page 243: Figure 5-82 Connecting External Battery Box To Chs1U-Au And Chs2U-Au Chassis

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect other end of cable to battery connector on rear of CHS1U-AU and CHS2U-AU chassis (refer to Figure 5-82 Connecting External Battery Box to CHS1U-AU and CHS2U-AU Chassis). Figure 5-82 Connecting External Battery Box to CHS1U-AU and CHS2U-AU...
  • Page 244: Figure 5-84 Re-Install Fan Access Panel (Chs2U-Au Chassis)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Insert the access panel tab into the slot on the rear of the CHS2U-AU chassis [see Figure 5-84 Re-Install Fan Access Panel (CHS2U-AU Chassis)]. Figure 5-84 Re-Install Fan Access Panel (CHS2U-AU Chassis) Secure panel withe retaining screw [refer to...
  • Page 245: Install External Batteries (With Chs Large Batt Box)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install External Batteries (with CHS LARGE BATT BOX) An external battery source with CHS LARGE BATT BOX can be used to long battery life in the event of a power failure. The CHS LARGE BATT BOX can provide 45 minutes backup time or 3 hours backup time.
  • Page 246: Hours Backup Time

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.3.2 3 Hours Backup Time One CHS LARGE BATT BOX can support one chassis (1U or 2U). Figure 5-86 CHS LARGE BATT BOX (3 Hours Battery Backup) Table 5-4 Battery Capacity of Multiple External Batteries...
  • Page 247: Figure 5-87 Chs Base Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Position the CHS BASE UNIT on desired surface and mark four holes to be drilled (refer to Figure 5-87 CHS BASE UNIT). Figure 5-87 CHS BASE UNIT Drill the four holes required for floor installation.
  • Page 248: Figure 5-89 Install Joint Brackets With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Secure the CHS LARGE BATT BOX to the CHS BASE UNIT using eight screws supplied with the CHS2U JOINT BRACKET KIT (refer to Figure 5-89 Install Joint Brackets with Screws bracket location). Figure 5-89 Install Joint Brackets with Screws...
  • Page 249: Figure 5-91 Removing Battery Tray

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Remove the battery tray bracket, then pull out the battery tray from CHS LARGE BATT BOX (refer to Figure 5-91 Removing Battery Tray). Figure 5-91 Removing Battery Tray Remove the top cover and battery bracket from the battery tray...
  • Page 250: Figure 5-93 Mounting Batteries

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Mount the batteries in the battery tray, then fix the batteries by the battery bracket (refer to Figure 5-93 Mounting Batteries). Figure 5-93 Mounting Batteries Connect the provided battery cables to the batteries (7AH-12V battery). (Refer to Figure 5-94 Connecting Battery Cables).
  • Page 251: Figure 5-95 Install Top Cover Of Battery Tray

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install the top cover of battery tray (refer to Figure 5-95 Install Top Cover of Battery Tray). Figure 5-95 Install Top Cover of Battery Tray Insert the battery tray into the CHS LARGE BATT BOX.
  • Page 252: Figure 5-97 Install Chs Large Batt Box Front Cover

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the front cover (refer to Figure 5-97 Install CHS LARGE BATT BOX Front Cover). Figure 5-97 Install CHS LARGE BATT BOX Front Cover Connect the IP3-L BATT BOX CABLE between the terminal unit in the CHS LARGE BATT BOX and battery connector of the...
  • Page 253: Chs Large Batt Box Fuse Replacement

    UNIVERGE SV8100/SV8300 Issue No. 1.5 When providing 3 hours backup time: CHS LARGE BATT BOX Hole Chassis Figure 5-99 Cable Connection between Chassis and CHS LARGE BATT BOX (3 Hours Battery Backup) 4.3.3 CHS LARGE BATT BOX Fuse Replacement Loosen screw on front of CHS LARGE BATT BOX. Refer to Figure 5-100 Removing CHS LARGE BATT BOX Cover.
  • Page 254: Figure 5-101 Removing Battery Tray Suppressor

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove two screws from front of Battery Tray Suppressor. Refer to Figure 5-101 Removing Battery Tray Suppressor. Figure 5-101 Removing Battery Tray Suppressor Slide Battery Tray Suppressor outward to remove. Disconnect the Battery Connection Cables from the Fuse Unit.
  • Page 255: Figure 4-76 Connecting Battery Cables

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 5-103 CHS LARGE BATT BOX Fuse Unit Slide the Fuse Unit into the and tighten the two screws (refer to Figure 5-102 Disconnecting Battery Cables on page 5-70). Plug the Battery Connection Cables into the Fuse Unit. Refer to Figure 5-104 Connecting Battery Cables on page 5-71.
  • Page 256: Remove And Install Cooling Fan

    CHS1U-AU Chassis 5.1.1 Remove Cooling Fan To reduce the possibility of electrical shock or damage to equipment, NEC recommends powering Off the chassis and disconnecting the AC cable from the power source before removing the chassis cover. Ensure the chassis is powered down.
  • Page 257: Figure 5-106 Chs1U-Au Chassis Access Panel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Loosen retaining screw from chassis access panel. Retaining Screw Figure 5-106 CHS1U-AU Chassis Access Panel Swing access panel outward and unplug fan power cable. See Figure 5-107 Opening Chassis Access Panel (CHS1U-AU Chassis). Fan Power Cable...
  • Page 258: Install Cooling Fan

    CHS2U-AU Chassis 5.2.1 Remove Cooling Fan To reduce the possibility of electrical shock or damage to equipment, NEC recommends powering Off the chassis and disconnecting the AC cable from the power source before removing the chassis cover. Ensure the chassis is powered down.
  • Page 259: Figure 5-110 Opening Chassis Access Panel (Chs2U-Au Chassis)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Swing access panel outward and unplug fan power cable. Refer Figure 5-110 Opening Chassis Access Panel (CHS2U-AU Chassis). Fan Power Cable Plug Figure 5-110 Opening Chassis Access Panel (CHS2U-AU Chassis) Remove chassis access panel from rear of chassis.
  • Page 260: Install Cooling Fan

    Issue No. 1.5 UNIVERGE SV8100/SV8300 5.2.2 Install Cooling Fan Align replacement fan with holes and secure with two screws [refer to Figure 5-111 Chassis Access Panel Removed (CHS2U-AU Chassis) on page 5-75]. Install cabling into retention clips [refer to Figure 5-111 Chassis Access Panel Removed (CHS2U-AU Chassis) on page 5-75].
  • Page 261: Chapter 6 Installing The Sv8100/Sv8300 Blades

    ENERAL NFORMATION ECTION This chapter contains information to help the technician install the blades for the UNIVERGE SV8100/SV8300 system. The technician should be familiar with this section before installing any equipment. Slot Locations Each CHS2U-AU has six slots. In the Controlling Chassis, the CD-CP00-AU (for Key Systems) must be installed in the first slot (slot 1).
  • Page 262: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Controlling Chassis CPU Slot Expansion Chassis PZ-BS11 Slot Figure 6-1 19” Chassis CPU and Expansion Slot Locations NSTALLATION ECTION Pre-installation planning is essential. Advanced planning minimizes installation time, cost, and disruption of the customer business activities.
  • Page 263: Installing An Extension Or Trunk Blade

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Use caution when installing or modifying telephone lines. Ground the Controlling and Expansion chassis before installing or removing the blades. The Expansion Chassis must be installed with the system power OFF. Do not touch the blade components.
  • Page 264: Order Of Installing Extension Blades

    Issue No. 1.5 UNIVERGE SV8100/SV8300 2.2.2 Order of Installing Extension Blades The order in which the station blades ( CD-8DLCA ) are CD-16DLCA PZ-8DLCB CD-4LCA CD-8LCA PZ-8LCE physically inserted determines the numbering plan. To avoid unexpected extension/trunk numbering if the VoIP or Voice Mail blades register with the...
  • Page 265: Order Of Installing Trunk Blades

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 6-2 Adding Daughter Board to Chassis Example Initial Blade Updated Blade Blade Extension Blade Extension Blade Blade Slot # Numbers Slot # Numbers CD-16DLCA 101~116 CD-16DLCA 101~116 CD-8DLCA 117~124 — — (no daughter board)
  • Page 266: Remove An Extension Or Trunk Blade

    Issue No. 1.5 UNIVERGE SV8100/SV8300 For example, if four blades are installed in the following order, the numbering plan below applies. Table 6-3 Trunk Blade Installation Order Example Order of Blade Slot Blade Line Circuits Installation Number CD-4COTC with PZ-4COTG...
  • Page 267: Uninstalling A Blade Slot Through Software

    Refer to Program 90-05 in the UNIVERGE SV8100 Programming Manual for detailed programming information. Blade Capacities The universal architecture of the UNIVERGE SV8100/SV8300 provides flexibility when installing blades. With the exception of the CD-CP00-AU and CC-CP00 blades, any blade can be installed in any slot.
  • Page 268: Performing A Hot Start

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Release the Load button. When the system has completed reloading the software (two minutes), the Status LED is flashing on the CD-CP00-AU. 2.6.2 Performing a Hot Start The section describes how to load system software from flash memory and customer data from RAM memory.
  • Page 269: Table 6-4 Default Port Settings

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.6.3.2 Port Defaults With the default settings, the ports are assigned as follows: Table 6-4 Default Port Settings Port 1~99 : 101~199 Station Ports: Port 100~199 : 3101~3200 Port 200~512 : 3201~3513 Port 1~99 : 201~299...
  • Page 270 Issue No. 1.5 UNIVERGE SV8100/SV8300 The display shows Complete Data Save when completed and the telephone becomes idle. 2.6.3.5 Backing Up/Restoring a Database As a precaution, it is recommended that the customer database be saved prior to updating the system software.
  • Page 271: Performing A Software Upgrade

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.6.4 Performing a Software Upgrade This section describes the procedure to perform a software upgrade on the CD-CP00-AU. IMPORTANT CONSIDERATIONS To save customer data prior to updating, a blank USB Memory is required. Insert the USB Memory into the USB Port on the CD-CP00-AU blade.
  • Page 272 Issue No. 1.5 UNIVERGE SV8100/SV8300 Wait until the Status LEDs on the CD-CP00-AU have the following indications (approximately two minutes): LED 2: Flashing Red LED 3: Flashing Red LED 4: Flashing Red LED 5: Steady Red Turn the system power off and un-install the USB Memory.
  • Page 273: Figure 6-3 Cd-Cp00-Au Blade Layout

    UNIVERGE SV8100/SV8300 Issue No. 1.5 OMMON ONTROL LADES ECTION The blades described in this section control the common functions of the chassis. CD-CP00-AU (SV8100 Central Processing Unit) PZ-32IPLA PZ-64IPLA PZ-128IPLA Battery Fast Ethernet CN7 BGM/EXSP Control CN 10 USB CN5...
  • Page 274: Description

    Issue No. 1.5 UNIVERGE SV8100/SV8300 PZ-32IPLA PZ-64IPLA Battery PZ-128IPLA CompactFlash PZ-VM21 PZ-ME50- Figure 6-4 CD-CP00-AU Blade with Daughter Boards Installed 3.1.1 Description The CD-CP00-AU blade is available only for the SV8100 system. The CD-CP00-AU controls all the functions and operations of the SV8100 system using the system software loaded into the CD-CP00-AU memory.
  • Page 275 UNIVERGE SV8100/SV8300 Issue No. 1.5 The CD-CP00-AU provides: 200 trunk ports maximum 512 extension ports maximum – 512 ports digital/IP extensions maximum – 320 digital ports maximum – 368 analog ports maximum 256 virtual extensions Connection for PZ-32IPLA/PZ-64IPLA/PZ-128IPLA Daughter Board...
  • Page 276 Issue No. 1.5 UNIVERGE SV8100/SV8300 C-Channel Control Conference: 64 Channels Caller ID Receiver; 32 Channels Caller ID Generator; 4 or 10 Channels for Analog Stations This can be expanded up to 20 by disabling 32 channels of the Conference circuits and disabling the MFC Tone Sender...
  • Page 277: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.1.2 Installation Each SV8100 system must have the CD-CP00-AU installed in Slot 1 of the Controlling Chassis. IMPORTANT INSTALLATION NOTES The chassis power must be off when installing or removing the CD-CP00-AU. After removing a previously installed CD-CP00-AU, handle the blade, carefully, from the edges.
  • Page 278: Switch Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Ensure the power supply is OFF, then slide the CPU into the CCPU slot in the Controlling Chassis. If external Background Music (BGM) or Music on Hold (MOH) is being installed, plug the cable into the CN8 or CN9 pin jack connector on the CPU.
  • Page 279: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 6-6 CD-CP00-AU Switch 6 Settings Configuration Note SW6-1 Not Used SW6-2 Test Mode ON = Test Mode OFF = Normal SW6-3 RS232C Select ON = Use OFF = Not Used SW6-4 Reset Configuration ON = Normal OFF = ICE Mode 3.1.4...
  • Page 280: Connectors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-7 CD-CP00-AU LED Indications (Continued) LED Indication Status RUN (LED1) LED2 LED3 LED4 LED5 Access On Steady When Upgrading system software Blink USB Memory is Installing Blinking Blinking Blinking On Steady When Finish formatting (SRAM,...
  • Page 281: Table 6-9 Cd-Lta Rj11 Cable Connector Pin-Outs

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 6-8 CD-CP00-AU Connections (Continued) Connector Connector Description CN6/SW2 Used for Debug Ethernet Cable Connection (for PCPro or WebPro, CTI, ACD MIS, IP Phone) CN8/CN9 Pin Jack for External Source Connection (External MOH, External Speaker, etc.)
  • Page 282: Cc-Cp00 (Sv8300 Central Processing Unit)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-9 CD-LTA RJ11 Cable Connector Pin-Outs (Continued) Pin No. Connection EXCNT2 EXCNT1 EXCNT1 EXCNT2 CC-CP00 (SV8300 Central Processing Unit) Battery PZ-64IPLA Battery PZ-128IPLA Memory Memory PZ-VM21 Status L$ED CompactFlash (Not Used) Ethernet Sense Relay...
  • Page 283: Description

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.2.1 Description The CC-CP00 blade is available only for the SV8300 system. The CC-CP00 controls all the functions and operations of the SV8300 system using the system software loaded into the CC-CP00 memory. The system software can be upgraded as new software becomes available.
  • Page 284 Two Serial Ports (null modem/cross-over cable required) One USB Port – USB 1.1/2.0 (requires USB driver – download from NEC web site) Not Used One Gbit Ethernet Port for VOIPDB One Fast Ethernet Port (10 Base-T/100 Base-TX)
  • Page 285: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 HDLC Packet Processing Real Time Clock (tolerance 30 seconds/month) Internal MOH Generation (supplied from Melody IC) Call Control Server (ex: Voice Mail Server, SIP Server, RTP Forwarding, VoCoder Conversion) One Connector for PAL EPROM One lithium battery (Sony CR2032 or equivalent) which provides...
  • Page 286: Table 6-10 Cc-Cp00 Switch Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 If external Music on Hold (MOH) is being installed, plug the cable into the CN8 or CN9 pin jack connector on the CPU. The other end of the cable plugs into the music source. Refer to the PGD(2)-U( ) ADP in...
  • Page 287: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.2.4 LED Indications Table 6-11 CC-CP00 LED Indications provides a list of each LED and its associated operation and status indications. Refer to Figure 6-6 CC-CP00 Blade on page 6-22 for the location of the LEDs on the CC-CP00.
  • Page 288: Connectors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-11 CC-CP00 LED Indications (Continued) Color Status Status indications of MJ/MN alarm. MJ alarm Blinking MN alarm Normal status LINK Green Status indications of link on ETHERNET port. Link is established Blinking Link is established (When receiving a packet.)
  • Page 289: Table 6-13 Cc-Cp00 Connector Pin-Outs

    UNIVERGE SV8100/SV8300 Issue No. 1.5 T1 Trunks ACD/inDepth PRI Trunks BRI S-Bus/T-Bus E&M Trunks Networking Table 6-13 CC-CP00 Connector Pin-Outs Ethernet Cable Connector – ETHERNET (RJ-45) (10Base-T/100Base-TX) Pin No. Signal Pin Jack – MOH (No Polarity) Pin No. Signal EXT1 EXT2 RJ-45 Cable Connector –...
  • Page 290 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-13 CC-CP00 Connector Pin-Outs (Continued) USB Cable Connector – USB (Type A, Female) (USB 1.1/2.0 Standard) [Not Used] Pin No. Signal 1 2 3 4 RJ-45 Cable Connector – EX IN/EX OUT (Polarity) Pin No.
  • Page 291: Pz-Me50-Au (Memory Expansion Daughter Board)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 PZ-ME50-AU (Memory Expansion Daughter Board) Figure 6-7 PZ-ME50-AU Daughter Board 3.3.1 Description The PZ-ME50-AU Daughter Board is available for the SV8100 systems. The Memory Expansion daughter board provides additional memory for the system to use with license control, expanded system networking, and software updates.
  • Page 292: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-15 PZ-ME50-AU Capacities provides the maximum capacities for the PZ-ME50-AU blade. Table 6-15 PZ-ME50-AU Capacities Memory System System 256 NetLink Basic System Expansion Unlimited Port (Networked Board Port CD-CP00-AU License Chassis) PZ-ME50-AU License 64 Ports without –...
  • Page 293: Pz-Vm21 (Voice Mail Daughter Board)

    64 using PCPro, perform a new download before attempting to program the ports. PZ-VM21 (Voice Mail Daughter Board) Figure 6-8 PZ-VM21 Daughter Board 3.4.1 Description PZ-VM21 is common to both UNIVERGE SV8100/SV8300 systems. System Hardware Manual 6 - 33...
  • Page 294: Table 6-16 Compactflash Voice Mail Specifications

    Depending on the compact flash card used, the voice mail can provide: Table 6-16 CompactFlash Voice Mail Specifications Part Numbers and UNIVERGE SV8100/SV8300 VM8000 InMail Capacities 4422043 UNIVERGE SV8100/SV8300 VM8000 InMail 512M Drive (1) 32-hour CompactFlash Card with software. 4426022 UNIVERGE SV8100/SV8300 VM8000 InMail 8-Port License 4426020...
  • Page 295: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.4.2 Installation To install a PZ-VM21 on the CD-CP00-AU or CC-CP00: Do not remove or install the CD-CP00-AU or CC-CP00 with the power on. Included with the PZ-VM21 are four plastic spacers. Install the plastic spacers on the PZ-VM21. Make sure to attach the spacers so that they extend out on the side of the daughter board which has the CN1 connector.
  • Page 296: Switch Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 6-9 Installing the PZ-VM21 One PZ-VM21 blade providing InMail can be installed per system. Refer to the UNIVERGE SV8100/SV8300 System InMail System Guide for complete set-up information. 3.4.3 Switch Settings This daughter board does not have any switch that needs to be set and does not require any hardware setting.
  • Page 297: Pz-32Ipla/Pz-64Ipla/Pz-128Ipla (Voice Over Ip Daughter Boards)

    PCM signal format and connects to the PCM time division switch. The PZ-32IPLA/PZ-64IPLA/PZ-128IPLA daughter board is required for IP telephones to communicate with non-VoIP UNIVERGE SV8100/ SV8300 telephones, and place or receive outside calls. The VoIP daughter board provides the voice (RTP/RTCP) processing function.
  • Page 298: Installation

    4-25 for more details. Connect the IPLA daughter board to the CD-RTB or to an external switching hub using an ethernet cable. Refer to the UNIVERGE SV8100 Programming Manual for detailed programming instructions 3.5.3 Switch Settings This daughter board does not have any switch that needs to be set and does not require any hardware setting.
  • Page 299: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.5.4 LED Indications LED indications for the PZ-32IPLA, PZ-64IPLA and PZ-128IPLA Daughter Boards are indicated in Table 6-17 IPLA Daughter Board Indications. Each LED is listed with its associated function and LED and Operational status. Refer to...
  • Page 300: Connectors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.5.5 Connectors Figure 6-11 VoIP Connections shows a typical connection layout. Figure 6-12 Connecting an IPLA Daughter Board to a Network/PC illustrates how to connect a VoIP Daughter Board to a Network or PC. Figure 6-11 VoIP Connections...
  • Page 301 UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 6-12 Connecting an IPLA Daughter Board to a Network/PC System Hardware Manual 6 - 41...
  • Page 302: Station Blades

    Issue No. 1.5 UNIVERGE SV8100/SV8300 TATION LADES ECTION CD-8DLCA/CD-16DLCA (Digital Station Interface) Figure 6-13 CD-8DLCA Blade 6 - 42 Installing the SV8100/SV8300 Blades...
  • Page 303: Description

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 6-14 CD-16DLCA Blade 4.1.1 Description The CD-8DLCA and the CD-16DLCA are available for both the SV8100 and SV8300 systems. Both are discussed in this section. Any differences between the two are noted. These blades provide:...
  • Page 304: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.1.2 Installation The CD-8DLCA/CD-16DLCA blades can be installed in any universal slot in the system and up to a maximum of 20 DLCA blades can be installed per system, providing up to 320 digital ports.
  • Page 305: Figure 6-13 Cd-8Dlca Blade

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Any cabling to the DLCA blade must be in the building - no outside cabling is permitted. Table 6-20 CD-8DLCA/CD-16DLCA/ RJ-61 Cable Connector Pin-Outs on page 6-45 show the pin-outs for the RJ-61 connector. Refer to...
  • Page 306: Pz-8Dlcb (Digital Station Daughter Board)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 PZ-8DLCB (Digital Station Daughter Board) Figure 6-15 PZ-8DLCB Blade 4.2.1 Description The PZ-8DLCB daughter board is common to both UNIVERGE SV8100/SV8300 systems. The PZ-8DLCB daughter board provides eight digital extensions. This daughter board is installed on the CD-8DLCA and expands the port capacity for the combined blades to 16.
  • Page 307: Table 6-21 Pz-8Dlcb Cn301 Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 The following tables show the cable connections of the two RJ-61 connectors on the PZ-8DLCB. Table 6-21 PZ-8DLCB CN301 Connection RJ-61 Cable Connector CN301 (ports 9~12) Pin No. Connection (T4) Tip for port 12 (T3) Tip for port 11...
  • Page 308: Cd-4Lca/ Cd-8Lca (4-Port/8-Port Single Line Interface)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 CD-4LCA/ CD-8LCA (4-Port/8-Port Single Line Interface) Figure 6-16 CD-4LCA Blade 6 - 48 Installing the SV8100/SV8300 Blades...
  • Page 309: Description

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 6-17 CD-8LCA Blade 4.3.1 Description The CD-4LCA CD-8LCA blade is common to both UNIVERGE SV8100/SV8300 systems. The 4/8LC blades provide four (4LC) analog extension ports or eight (8LC) analog extension ports (used for on-premise analog telephones, fax machines, and analog modems).
  • Page 310: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Constant current type battery feeding (25mA / -28Vdc) Feeding Polarity Reverse Ability Connector for PZ-4LCA/PZ-8LCE Daughter Boards Ring Generator Caller ID Sending Ability Message Wait Lamp Ability The CD-8LCA consumes eight ports ranging between ports 001~256.
  • Page 311: Connectors

    UNIVERGE SV8100/SV8300 Issue No. 1.5 LED indications for the CD-4LCA CD-8LCA are listed in Table 6-23 CD-4LCA/CD-8LCA LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 6-16 CD-4LCA Blade on page 6-48...
  • Page 312: Pz-4Lca/Pz-8Lce (4-Port/8-Port Sli Daughter Boards)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 PZ-4LCA/PZ-8LCE (4-Port/8-Port SLI Daughter Boards) Figure 6-18 Installing the PZ-4LCA Daughter Board 6 - 52 Installing the SV8100/SV8300 Blades...
  • Page 313: Description

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 6-19 Installing the PZ-8LCE Daughter Board 4.4.1 Description The PZ-4LCA and PZ-8LCE daughter boards are mounted on the CD-4LCA/CD-8LCA. These boards provide: 4-Port Single Line and 8-Port Single Line analog extension ports (used for on-premise analog telephones, fax machines, and analog modems).
  • Page 314: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connector for CD-4LCA and CD-8LCA Blades One extension status LED Two status LEDs Ring Generator Caller ID Sending Ability Message Wait Lamp Ability Constant current type battery feeding (25mA / -28Vdc) Feeding Polarity Reverse Ability...
  • Page 315: Figure 6-18 Installing The Pz-4Lca Daughter Board

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Position the PZ-4LCA PZ-8LCE CN1 connector over the CN4 connector on the SLIU blade. Press the boards together, ensuring the plastic spacers lock in place. Refer to Figure 6-18 Installing the PZ-4LCA Daughter Board on page 6-52...
  • Page 316: Cd-Lta (D Term /Slt Combination)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 term CD-LTA (D /SLT Combination) Figure 6-20 CD-LTA Blade 4.5.1 Description The CD-LTA blade is available only for the SV8100 system. The Digital Station/SLT Combination blade provides eight Digital Station ports and two analog ports. This blade allows for either a PZ-4COTG analog trunk daughter board or PZ-2BRIA daughter board to be installed.
  • Page 317: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Two status LEDs Table 2-4 SV8100 Maximum System Capacities – Blades on page 2-7 provides the maximum capacities for the CD-LTA blade when upgraded. Table 6-26 CD-LTA Maximum Capacities provides the maximum capacities (for the CD-LTA blades) when installed.
  • Page 318: Led Indications

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.5.3 LED Indications LED indications for the CD-LTA are indicated in Table 6-27 CD-LTA Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 6-20 CD-LTA Blade on page 6-56 for the location of the LEDs on the blade.
  • Page 319: Connectors

    UNIVERGE SV8100/SV8300 Issue No. 1.5 4.5.4 Connectors Table 6-28 CD-LTA RJ11 Cable Connector Pin-Outs on page 6-59 shows the pin-outs for the RJ-61 connector. Refer to Figure 6-20 CD-LTA Blade on page 6-56 for an illustration showing the location of the connectors on the CD-LTA blade.
  • Page 320: Trunk Blades

    ECTION CD-4COTC (4 Loop Start Trunk Interface) Figure 6-21 CD-4COTC Blade 5.1.1 Description The CD-4COTC blade is common to both UNIVERGE SV8100/ SV8300 systems. The CD-4COTC blade provides: CD-4COTC: Four analog loop start trunk circuits One trunk status LED One Blade status LED...
  • Page 321: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Two Power Failure Transfer Circuits Connection for PZ-4COTG Daughter Board The CD-4COTC blade consumes four trunk ports ranging between ports 001~200. The CN2 connector provides connection to four analog trunk ports.. When using the CD-4COTC blade for ground...
  • Page 322: Led Indications

    Issue No. 1.5 UNIVERGE SV8100/SV8300 5.1.3 LED Indications LED indications for the CD-4COTC are listed in Table 6-29 CD-4COTC LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 6-21 CD-4COTC Blade on page 6-60 for the location of the LEDs on the blades.
  • Page 323: Connectors

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.1.4 Connectors Table 6-30 CD-4COTC RJ-61 Cable Connector Pin-Outs on page 6-63 shows the pin-outs for the RJ-61 connector. Refer to Figure 6-21 CD-4COTC Blade on page 6-60 for an illustration showing the location of the connectors on the CD-4COTC blades.
  • Page 324: Pz-4Cotg (4 Loop Start Trunk Interface Daughter Board)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 PZ-4COTG (4 Loop Start Trunk Interface Daughter Board) Figure 6-22 Installing the PZ-4COTG Daughter Board 5.2.1 Description The PZ-4COTG daughter board is common to both UNIVERGE SV8100/SV8300 systems. The PZ-4COTG daughter board provides: PZ-4COTG: Four analog loop start trunk circuits...
  • Page 325: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 The PZ-4COTG consumes four trunk ports ranging between ports 001~200. The CN2 connector provides connection to four analog trunk ports. When using the PZ-4COTG daughter board for ground start trunks, the PBX ground must be...
  • Page 326: Connectors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 5.2.3 Connectors Table 6-31 PZ-4COTG RJ-61 Cable Connector Pin-Outs on page 6-66 shows the pin-outs for the RJ-61 connector. Figure 6-22 Installing the PZ-4COTG Daughter Board on page 6-64 shows the location of the connectors on the PZ-4COTG blades.
  • Page 327: Cd-2Bria (2 Basic Rate Interface)

    Issue No. 1.5 CD-2BRIA (2 Basic Rate Interface) Figure 6-23 CD-2BRIA Blade 5.3.1 Description The CD-2BRIA blade is common to both UNIVERGE SV8100/SV8300 systems. This unit is an interface unit that accommodates an ISDN (Basic Rate) circuit. The BRI blade provides:...
  • Page 328: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 These trunk circuits T-Bus (SV8100) or S-Bus (SV8300 only) can be connected to either ISDN trunks or ISDN telephones, depending on the switch setting in system programming. All ISDN telephone circuits (#1-2 and #3-4 with the BRI daughter board) are supplied DC power from the system.
  • Page 329: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.3.3 LED Indications LED indications for the CD-2BRIA are listed in Table 6-32 CD-2BRIA Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 6-23 CD-2BRIA Blade on page 6-67 for the location of the LEDs on the blade.
  • Page 330 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-33 CD-2BRIA RJ-61 Cable Connector Pin-Outs (Continued) RJ-61 Cable Connector – CN7, CN8 Pin No. Connection — — — — 6 - 70 Installing the SV8100/SV8300 Blades...
  • Page 331: Pz-2Bria (2 Basic Rate Interface Daughter Board)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 PZ-2BRIA (2 Basic Rate Interface Daughter Board) Figure 6-24 Installing the PZ-2BRIA Daughter Board 5.4.1 Description The PZ-2BRIA daughter board is common to both UNIVERGE SV8100/SV8300 systems. This daughter board provides two BRI circuits and is installed on the CD-2BRIA blade.
  • Page 332: Installation

    All ISDN telephone circuits [#1-2 (BRI blade) and #3-4 (with the BRI daughter board)] are supplied DC power from the UNIVERGE SV8100/SV8300 system. System programming must be used to block new calls on the blade.
  • Page 333: Connectors

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.4.3 Connectors Table 6-34 PZ-2BRIA RJ-61 Cable Connector Pin-Outs shows the pin- outs for the RJ-45 cable connector for S-Bus and T-Bus connections. Figure 6-24 Installing the PZ-2BRIA Daughter Board on page 6-71 shows the location of the connectors on the PZ-2BRIA daughter board.
  • Page 334: Cd-4Diopa (Opx Telephone Interface)

    CD-4DIOPA (OPX Telephone Interface) Figure 6-25 CD-4DIOPA Blade 5.5.1 Description The CD-4DIOPA blade is common to both UNIVERGE SV8100/ SV8300 systems. The CD-4DIOPA supports the analog DID and single line telephone interface functions (such as Off-Premise Extension). The function type is assigned in programming for each port.
  • Page 335: Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Refer to the following table for maximum upgrade capacities of the CD-4DIOPA blade: Table 2-4 SV8100 Maximum System Capacities – Blades on page 2-7 Analog DID not supported in Australia. 5.5.2 Installation The CD-4DIOPA can be installed in any universal slot.
  • Page 336: Table 6-36 Cd-4Diopa Rj-61 Cable Connector Pin-Outs

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-36 CD-4DIOPA RJ-61 Cable Connector Pin-Outs on page 6-76 shows the pin-outs for the RJ-61 connector. Figure 6-25 CD-4DIOPA Blade on page 6-74 shows the location of the connectors on the 4DOIPA blade. Table 6-36 CD-4DIOPA RJ-61 Cable Connector Pin-Outs RJ-61 Cable Connector –...
  • Page 337: Cd-Prta (Primary Rate Interface)

    Figure 6-26 CD-PRTA Blade (Front and Side View) 5.6.1 Description The CD-PRTA blade is common to both UNIVERGE SV8100/SV8300 systems. The CD-PRTA PRI blade provides an interface for ISDN Primary Rate Interface (PRI) applications. This blade has a single 30-channel 2Mb per second digital signal circuit.
  • Page 338: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Speech and 3.1 KHz audio When installed, CD-PRTA uses the first block of 30 consecutive trunk ports. For example, if a COIU blade is installed for trunks 1~8, the CD-PRTA automatically uses trunks 9~38. If the COIU blades are installed for trunks 1~8 and 17~24, CD-PRTA uses trunks 25~55.
  • Page 339: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.6.3 LED Indications LED indications for the CD-PRTA are listed in Table 6-38 CD-PRTA Indications. Each LED is listed with its associated function and LED and Operational status. Table 6-37 CD-PRTA LED Indications LED Indication...
  • Page 340: Figure 6-28 Cd-Prta Led Indication Pattern Of Layer 1 On Pri Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Refer to Figure 6-28 CD-PRTA LED Indication Pattern of Layer 1 on PRI Unit on page 6-80 for LED pattern information. LED indications for the ISDN are listed in Table 6-38 CD-PRTA LED Indications on page 6-80.
  • Page 341: Table 6-39 Cd-Prta Rj-45 Cable Connector Pin-Outs

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.6.4 Connectors Table 6-39 CD-PRTA RJ-45 Cable Connector Pin-Outs shows the pin- outs for the RJ-45 connector. Figure 6-26 CD-PRTA Blade (Front and Side View) on page 6-77 shows the location of the connectors on the PRIU blade.
  • Page 342: Table 6-40 Cd-Prta Rj48C Connector Pin-Outs

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-40 CD-PRTA RJ48C Connector Pin-outs shows the pin-outs for the 8-pin RJ48C connector for the network and terminal interfaces. Table 6-40 CD-PRTA RJ48C Connector Pin-outs Network Interface Terminal Interface Pinout for the 8-Pin Pinout for the 8-Pin...
  • Page 343: Cd-4Odta (4-Port Tie Line Interface Blade)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 CD-4ODTA (4-Port Tie Line Interface Blade) Figure 6-29 CD-4ODTA Blade 5.7.1 Description The CD-4ODTA Tie Line blade is an out band dial type analog tie line interface blade. This blade supports system connections to either 2- wire (four lead, tip/ring) or 4-wire (six lead, tip/ring/tip 1/ring 1) E&M...
  • Page 344: Installation

    Limitation depends on the connecting Router, Multiplexer or Exchange. If the UNIVERGE SV8100/SV8300 is connected to another UNIVERGE SV8100/SV8300 directly, there is up to 1,500 ohms loop resistance (including system). Refer to the following table for maximum upgrade capacities of the CD-4ODTA blade: Table 2-4 SV8100 Maximum System Capacities –...
  • Page 345: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.7.3 LED Indications LED indications for the CD-4ODTA are listed in Table 6-41 CD-4ODTA Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 6-29 CD-4ODTA Blade on page 6-83 for the location of the LEDs on the blade.
  • Page 346 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-42 CD-4ODTA RJ-61 Cable Connector Pin-Outs RJ-61 Cable Connector – 2-Wire E&M, CN1A~CN1D Pin No. Connection Description — Not Used Control signal to trunk — Not Used Voice signal both ways Voice signal both ways —...
  • Page 347: Connections

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.7.5 Connections Figure 6-30 Voice Signal Connection for Type I And V on page 6-87 Figure 6-31 Control Signal Connection on page 6-88 show the signaling methods for circuit types. Figure 6-30 Voice Signal Connection for Type I And V...
  • Page 348: Figure 6-31 Control Signal Connection

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 6-31 Control Signal Connection 6 - 88 Installing the SV8100/SV8300 Blades...
  • Page 349: Optional Blades

    Description The CD-VM00 blade is common to both UNIVERGE SV8100/SV8300 systems. This blade is a PC platform installed in the UNIVERGE SV8100/ SV8300 that contains data storage for voice recording and application software supporting a maximum of 16 ports. A digital signal processor/voice processing section handles the...
  • Page 350: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 6.1.2 Installation Only one CD-VM00 can be installed per system. Handle the CF drive carefully. To prevent damage, do not drop the drive or apply pressure to it. This unit makes extensive use of CMOS technology and is very susceptible to static;...
  • Page 351: Led Indications

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install the Compact Flash drive into slot CN7, make sure the drive is fully seated in the slot (refer to Figure 6-35 Install the Compact Flash Drive). Figure 6-35 Install the Compact Flash Drive 6.1.3 LED Indications 6.1.3.1 Active LED –...
  • Page 352: Figure 6-36 Cd-Vm00 Db9 To 6-Pin Modular Rs-232 Adapter

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The CompactFlash Card Activity LED is controlled by the IDE controller and indicates read/write activity on the CompactFlash card. 6.1.4 Connectors The following sections go into detail on each of the user interfaces. 6.1.4.1 RS-232 Interface...
  • Page 353: Figure 6-37 Cd-Vm00 Rs-232 Serial Cable (Dte)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 6.1.4.3 RS-232 Serial Cable (DTE) Figure 6-37 CD-VM00 RS-232 Serial Cable (DTE) 6.1.4.4 RS-232 Serial Cable (DCE) Figure 6-38 CD-VM00 RS-232 Serial Cable (DCE) 6.1.4.5 USB Interface The APSU provides two USB interfaces that can be used...
  • Page 354: Cd-Ccta (Ccis Trunk Interlace)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The RJ-45 connector pin-out is shown in Table 6-43 Ethernet Connector Pin-Out on page 6-94. Table 6-43 Ethernet Connector Pin-Out View Pin No. Signal Note PIN1 ---- PIN8 10 Base-T/100 Base-TX port (RJ-45 connector) CD-CCTA (CCIS Trunk Interlace)
  • Page 355: Description

    UNIVERGE SV8100/SV8300 Issue No. 1.5 6.2.1 Description The CD-CCTA blade is supported by the UNIVERGE SV8300 only. The Common Channel Handler Interface blade is a digital trunk ETU that terminates E1 trunks (up to 30 DS-0 channels) providing a common channel signal interface.
  • Page 356: Connectors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 6-40 CD-CCTA LED Indication Pattern of Layer 1 on E1 Unit 6.2.4 Connectors Table 6-45 CD-CCTA RJ-45 Cable Connector Pin-Outs shows the pin- outs for the RJ-45 connector. Figure 6-39 CD-CCTA Blade on page 6-94 shows the location of the connectors on the CD-CCTA blade.
  • Page 357: Cabling And Mdf Connection

    Wiring Between the Chassis and the MDF 7.3.1 Chassis Cables The chassis is equipped with two MDF Cable Assemblies. NEC recommends that the MDF Cable Assembly be used to connect the multiline terminals, single line telephones (except PFT), PVAA and DID/OPX lines.
  • Page 358: Table 6-46 Mdf Cable Colors

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-46 MDF Cable Colors Cable Colors Outs BR–WH GN–RD BR–BK BL–YL SL–YL BR–VI GN–WH OR–RD BL–BK SL–BK BR–YL GN–VI OR–WH BL–RD SL–RD BR–GN GN–YL OR–VI WH–BL WH–SL RD–BR BK–GN YL–OR VI–BL BL–WH SL–WH BR–RD GN–BK...
  • Page 359 UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 6-47 MDF Cable Connections (Station) (Continued) Station DLCA Running Connector Cable Pin No. Cable DLCA COTC BK–GN TA–1 GN–BK TB–1 BK–BR RA–1 BR–BK RB–1 BK–SL TA–2 SL–BK TB–2 YL–BL RA–2 BL–YL RB–2 YL–OR TA–1 OR–YL...
  • Page 360 Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 6-48 MDF Cable Connections (Trunk) (Continued) Station COTC DIOPA PRTA Running Connector Cable BRIA CCTA Pin No. Cable WH–SL TA–1 SL–WH TB–1 RD–BL – RA–1 – BL–RD RB–1 RD–OR TA–2 OR–RD – TB–2 –...
  • Page 361: Table 6-47 Mdf Cable Connections (Station)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 7.3.2 Outside Lines The connection of CO lines is an RJ-61. The lines are connected in sequence in this termination block. Therefore, the lines must be ordered in the appearance order best suited to the user. Refer to...
  • Page 362 Issue No. 1.5 UNIVERGE SV8100/SV8300 - - NOTES - - 6 - 102 Installing the SV8100/SV8300 Blades...
  • Page 363: Chapter 7 Installing Dt300/Dt700 Series (Dtl/Itl)

    Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals ENERAL ESCRIPTION ECTION This chapter provides information about the DT300/DT700 Series digital and IP terminals in addition to the single line telephones, cordless telephones and wireless telephones. term Only the DT300/DT700, D Series i telephones, single line telephones, cordless telephones and wireless telephones discussed in the document can be installed on the SV8100/SV8300 systems.
  • Page 364: Table 7-2 Terminal And Adapter Compatibility

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The DT300/DT700 Series offers a line up of modular telephones. This modular design allows the telephones to be upgraded and customized. Optional LCD panels, keypads, handset cradles, face plates and colored side panels can easily be snapped on and off.
  • Page 365: Table 7-3 Terminal And Line Key/Lcd Compatibility

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 7-3 Terminal and Line Key/LCD Compatibility shows the compatibility between the terminals and Line Key or LCD used in the system. Table 7-3 Terminal and Line Key/LCD Compatibility Line Key/LCD Terminal 8 LK-L( )
  • Page 366: Table 7-4 Terminal And Tenkey Kit Compatibility

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 7-4 Terminal and Tenkey Kit Compatibility shows the compatibility between the terminals and Tenkey kits used in the system. Table 7-4 Terminal and Tenkey Kit Compatibility Tenkey Kit Terminal BS(F)-L( ) BS(S)-L( ) BS(ACD)-L( )
  • Page 367: Table 7-5 Terminal And Optional Equipment Compatibility

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 7-5 Terminal and Optional Equipment Compatibility shows the compatibility between the terminals and optional equipment used in the system. Table 7-5 Terminal and Optional Equipment Compatibility Equipment Terminal PSA-L( ) PANEL-L( ) WM-L( )
  • Page 368: Dt300 Series Digital Multiline Terminals

    Issue No. 1.5 UNIVERGE SV8100/SV8300 DT300 S ERIES IGITAL ULTILINE ERMINALS ECTION The DT300 Series offers a new exciting line up of digital telephones. These telephones (except economy), have a modular design that allows the telephones to be upgraded and customized. Optional LCD panels, dial pads, feature key kits, handset cradles, face plates and colored side panels can easily be snapped on and off to upgrade and customize as the customer desires.
  • Page 369: Dtl-6De-1( ) (Bk) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.1.2 DTL-6DE-1( ) (BK) TEL This digital economy multiline terminal has six line keys with display and is available in black only. The terminal features: Non-modular designSoftkeys Four-step adjustable base Half-duplex speaker phone Six line keys (Red, Green)
  • Page 370: Dtl-8Ld-1( ) (Bk) Tel/Dtl-8Ld-1( ) (Wh) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 2.1.3 DTL-8LD-1( ) (BK) TEL/DTL-8LD-1( ) (WH) TEL This digital value multiline terminal has eight line keys with display and is available in both black and white. The terminal features: Modular design Four-step adjustable base...
  • Page 371: Dtl-12D-1( ) (Bk) Tel/Dtl-12D-1( ) (Wh) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.1.4 DTL-12D-1( ) (BK) TEL/DTL-12D-1( ) (WH) TEL This digital value multiline terminal has 12 line keys and is available in both black and white. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 372: Dtl-12Pa-1( ) (Bk) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 2.1.5 DTL-12PA-1( ) (BK) TEL This digital value multiline terminal with Analog Power Failure adapter has 12 line keys and is available in black only. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 373: Dtl-24D-1( ) (Bk) Tel/Dtl-24D-1( ) (Wh) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 2.1.6 DTL-24D-1( ) (BK) TEL/DTL-24D-1( ) (WH) TEL This digital value multiline terminal has 24 line keys and is available in both black and white. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 374: Dtl-32D-1( ) (Bk) Tel/Dtl-32D-1( ) (Wh) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 2.1.7 DTL-32D-1( ) (BK) TEL/DTL-32D-1( ) (WH) TEL This digital value multiline terminal has 32 line keys (24 line keys plus eight line key LK Unit) and is available in both black and white. The...
  • Page 375: Dt700 Series Ip Multiline Terminals

    UNIVERGE SV8100/SV8300 Issue No. 1.5 DT700 S IP M ERIES ULTILINE ERMINALS ECTION The DT700 Series offers a new exciting line up of IP telephones. These telephones (except economy), have a modular design that allows the telephones to be upgraded and customized.
  • Page 376: Itl-6De-1( ) (Bk) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.1.2 ITL-6DE-1( ) (BK) TEL This IP economy multiline terminal has six line keys with display and is available in black only. The terminal features: Non-modular design Four-step adjustable base Remote login and maintenance Full-duplex speaker phone...
  • Page 377: Itl-8Ld-1( ) (Bk) Tel/Itl-8Ld-1( ) (Wh) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.1.3 ITL-8LD-1( ) (BK) TEL/ITL-8LD-1( ) (WH) TEL This IP value multiline terminal has eight line keys with display and is available in both black and white. The terminal features: Modular design Four-step adjustable base...
  • Page 378: Itl-12D-1( ) (Bk) Tel/Itl-12D-1( ) (Wh) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.1.4 ITL-12D-1( ) (BK) TEL/ITL-12D-1( ) (WH) TEL This IP value multiline terminal has 12 line keys and is available in both black and white. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 379: Itl-12Pa-1( ) (Bk) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.1.5 ITL-12PA-1( ) (BK) TEL This IP value multiline terminal with Analog Power Failure adapter has 12 line keys and is available in black only. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 380: Itl-24D-1( ) (Bk) Tel/Itl-24D-1( ) (Wh) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.1.6 ITL-24D-1( ) (BK) TEL/ITL-24D-1( ) (WH) TEL This IP value multiline terminal has 24 line keys and is available in both black and white. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone...
  • Page 381: Itl-32D-1( ) (Bk) Tel/Itl-32D-1( ) (Wh) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.1.7 ITL-32D-1( ) (BK) TEL/ITL-32D-1( ) (WH) TEL This IP value multiline terminal has 32 line keys (24 line keys plus an eight line key LK Unit) and is available in both black and white. The...
  • Page 382: Itl-320C-1( ) (Bk) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.1.8 ITL-320C-1( ) (BK) TEL This IP multiline terminal features a large color touch panel LCD and is available in black only. The terminal features: Modular design Four-step adjustable base Full-duplex speaker phone Protection button...
  • Page 383: Connecting The Dt300 Series Multiline Terminal To The System

    UNIVERGE SV8100/SV8300 Issue No. 1.5 NSTALL ULTILINE ERMINALS ECTION Connecting the DT300 Series Multiline Terminal to the System This instruction applies to all DT300 Series multiline terminals. Plug the telephone cord into the modular jack on the bottom side of the multiline terminal.
  • Page 384: Applying Power To The Dt700 Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Lead the Line and Handset cables through the applicable grooves. Figure 7-17 Leading Line Cords on a multiline terminal Applying Power to the DT700 Multiline Terminal The DT700 terminal supports two different power sources for the terminal:...
  • Page 385: Connecting The Ip Multiline Terminal To The Network And Pc

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connecting the IP Multiline Terminal to the Network and PC These instructions for connecting an IP multiline terminal to the Network and PC apply to DT700 multiline terminals. Refer to Figure 7-18 IP Terminal Connector Locations.
  • Page 386: Adjusting The Lcd On The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 7-19 Typical Network IP Connection Adjusting the LCD on the Multiline Terminal DT300/DT700 Series display multiline terminals have an adjustable Liquid Crystal Display (LCD). The LCD can be adjusted by pulling up or pushing down as desired.
  • Page 387: Installing Line Key Kit (12Lk-L Kit)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Installing Line Key Kit (12LK-L KIT The 12LK-L KIT Provides 12 additional buttons to ITL or DTL multiline terminals. The 12LK-L KIT kit: Mounts directly to top side of terminal Supports Red and Green LED colors Figure 7-21 12LK-L( ) Kit 4.5.1...
  • Page 388: Figure 7-23 Removing The Desi Sheet

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Lift and remove the DESI sheet. DESI Sheet Figure 7-23 Removing the DESI Sheet Press the right end of the Line Key placeholder and lift to remove (refer to Figure 7-24 Removing the Line Key Placeholder on page 7-26).
  • Page 389: Figure 7-25 Installing The 12Lk-L Kit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Install the 12LK-L KIT and press down until click is heard. 12LK-L KIT Figure 7-25 Installing the 12LK-L KIT If desired, print and install the new DESI sheet. Figure 7-26 Installing the DESI Sheet System Hardware Manual...
  • Page 390: Configuring The Digital Telephone For The Correct Number Of Line Keys

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the supplied Line Key Panel (refer to Figure 7-27 Installing the Line Key Panel). Line Key Panel Figure 7-27 Installing the Line Key Panel Install the side panel. Connect the line cord/LAN cable and the AC/DC adapter to the DTL/ITL multiline terminal.
  • Page 391: Configuring The Ip Telephone For The Correct Number Of Line Keys

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Save to memory by pressing line key 2, 8, 14 or 20. The display changes back to the Service Class R/W mode and the Message Waiting (MW) LED will be lit Red. Press Exit to return the telephone to the idle condition.
  • Page 392: Installing The Directory Card On The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Press the Up/Down key to select the Line Key kit being used. By default, the correct line key kit for the keypad kit selected above will be highlighted. Table 7-8 Line Key Kit Type Line Key Kit Entry...
  • Page 393: Installing A Numbered Keypad On The Multiline Terminal

    IPK II and IPS terminals. Standard Numbered Keypad The standard keypad (in black or white), is commonly delivered with the UNIVERGE SV8100/SV8300 terminal (refer to Figure 7-30 Standard Numbered Keypad on page 7-31).
  • Page 394: Installing The Numbered Keypad On A Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 BS (Retro)-L KIT term The optional Retro keypad (in black or white), is compatible with the Series i telephone, allowing the terminal to be used with the IPK II and IPS multiline terminals. Figure 7-31 BS (Retro)-L KIT 4.7.1...
  • Page 395: Figure 7-33 Removing Numbered Keypad From Dt300/Dt700 Series Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Pull down on the tab and lift the Numbered Keypad away from the telephone to remove the existing button. Refer to Figure 7-33 Removing Numbered Keypad from DT300/DT700 Series Terminal. Figure 7-33 Removing Numbered Keypad from DT300/DT700...
  • Page 396: Configuring The Digital Telephone For The Numbered Keypad

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Insert the DESI printer sheet and plastic panels on the multiline terminal. Refer to Figure 7-35 Install Plastic Panels. Line Key Panel Numbered Keypad Panel Desi Printer Sheet Figure 7-35 Install Plastic Panels 4.7.2 Configuring the Digital Telephone for the Numbered Keypad...
  • Page 397: Configuring The Ip Telephone For The Numbered Keypad

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Press line key 2, 8, 14 or 20 to save to memory. The display changes back to the Service Class R/W mode and the Red Message Waiting LED is lit. Press Exit to return the telephone to the idle condition.
  • Page 398: Adjusting The Height On The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Press the Up/Down key to select the line key kit being used. By default, the correct line key kit for the keypad kit selected above is highlighted. Table 7-11 Line Key Kit Type Line Key Kit Entry...
  • Page 399: Removing Or Installing The Tilt Legs On The Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Removing or Installing the Tilt Legs on the Multiline Terminal The Tilt Legs can be removed or installed on the DT300/DT700 Series multiline terminal. 4.9.1 Remove Tilt Legs Place the telephone on a flat surface (button side down).
  • Page 400: Install Tilt Legs

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.9.2 Install Tilt Legs Place the telephone on a flat surface (button side down). Lay the adjustable Tilt legs on top of the telephone. Refer to Figure 7-39 Attach Tilt Legs to DT300/DT700 Series Terminal.
  • Page 401: Wall Mounting The Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Snap legs together and adjust to desired height. Refer Figure 7-41 Adjust Height of DT300/DT700 Series Terminal. Figure 7-41 Adjust Height of DT300/DT700 Series Terminal 4.10 Wall Mounting the Multiline Terminal You can wall mount a DT300/DT700 Series connection multiline terminal using the base cover or an optional wall mount unit.
  • Page 402: Figure 7-43 Sliding The Hanger Hook Into Position

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Slide the hook until it glides into position forming the hanger hook for the handset. Figure 7-43 Sliding the Hanger Hook into Position 4.10.1.2 Wall Mounting the Multiline Terminal Plug line cord in the wall receptacle. Leave about...
  • Page 403: Figure 7-45 Plugging In Line Cord

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Plug the line cord into the multiline terminal as illustrated in Figure 7-45 Plugging in Line Cord. Figure 7-45 Plugging in Line Cord Align the two holes on the back of the multiline terminal with the two screws on the wall plate and...
  • Page 404: Figure 7-47 Removing The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.10.1.3 Removing the Multiline Terminal from the Wall Mounted Base Plate. To remove the multiline terminal, push up on the telephone until it comes loose. Figure 7-47 Removing the Multiline Terminal 4.10.1.4 Wall Mounting the Base on a Wall Plate...
  • Page 405: Figure 7-49 Wall Mounted Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Hang the multiline terminal on the base. Figure 7-49 Wall Mounted Multiline Terminal Because of strength variation in wall plates, this method is not recommended. System Hardware Manual 7 - 43...
  • Page 406: Dt300/Dt700 Series Terminal Options

    Issue No. 1.5 UNIVERGE SV8100/SV8300 ULTILINE ERMINALS PTIONAL QUIPMENT ECTION DT300/DT700 Series Terminal Options The following chart provides a quick overview of the options available with the DT300/DT700 Series telephones. Table 7-12 Connectivity of Options IP Terminals Digital Terminals Value...
  • Page 407: Figure 7-50 8Lk-L Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Supports Red and Green LED colors Figure 7-50 8LK-L UNIT 5.2.1.1 Installing the 8LK-L UNIT To prevent possible damage to the 8LK-L UNIT or the DTL/ITL multiline terminal during installation or removal, disconnect the line cord/LAN cable and the AC/DC adapter from the DTL/ITL multiline terminal.
  • Page 408: Figure 7-52 Securing The 8Lk-L Unit With Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Secure the 8LK-L UNIT with the two screws provided. Figure 7-52 Securing the 8LK-L UNIT with Screws Turn the multiline terminal upside down. Open the small door covering the side option connectors by pulling the cover handle to the front.
  • Page 409: 8Lkd (Ld)-L( ) (Bk) Unit/8Lkd (Ld)-L( ) (Wh) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.2.2 8LKD (LD)-L( ) (BK) UNIT/8LKD (LD)-L( ) (WH) UNIT Provides eight additional line keys to DT300 Series (DTL) terminals. The unit features: Mounts directly to top side of terminal Supports Desi-less 2 LCD panels...
  • Page 410: Figure 7-56 Ribbon Cable Connector

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove the screw (refer to Figure 7-55 Remove Side Panel from Multiline Terminal on page 7-47). Carefully, return the multiline terminal to the buttons side up position. Remove the Softkeys and Line Key kit from the telephone.
  • Page 411: Figure 7-57 Ribbon Cable Installed

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Press down on the black bar to lock the cable into place (refer to Figure 7-57 Ribbon Cable Installed on page 7-49). Guide Projection Guide (One Each Side) Figure 7-57 Ribbon Cable Installed Align the projections on the bottom of the 8LKD (LD)-L UNIT into the guide holes on top of the multiline terminal.
  • Page 412: 8Lki (Ld)-L( ) (Bk) Unit/8Lki (Ld)-L( ) (Wh) Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the screw (refer to Figure 7-59 Install Screw). Screw Side Panel Figure 7-59 Install Screw Attach the side panel to the side of the 8LKD (LD)-L UNIT (refer to Figure 7-65 Install Screw on page 7-53).
  • Page 413: Figure 7-61 Remove Side Panel From Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.2.3.1 Installing the 8LKI (LD)-L UNIT To prevent possible damage to the 8LKI (LD)-L UNIT or the ITL multiline terminal during installation or removal, disconnect the line cord/LAN cable and the AC/DC adapter from the ITL multiline terminal.
  • Page 414: Figure 7-62 Ribbon Cable Connector

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Gently lift the small black bar to open the ribbon cable connector. Lift Here Figure 7-62 Ribbon Cable Connector Plug ribbon cable on back of 8LKI (LD)-L UNIT into connector (metal side down) until pressure is felt.
  • Page 415: Figure 7-64 8Lki (Ld)-L Unit Installed

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the projections on the bottom of the 8LKI (LD)-L UNIT into the guide holes on top of the multiline terminal (refer to Figure 7-63 Ribbon Cable Installed). Slide the 8LKI (LD)-L UNIT toward the keypad...
  • Page 416: Dcl-60-1( ) (Bk) Console/Dcl-60-1( ) (Wh) Console

    Issue No. 1.5 UNIVERGE SV8100/SV8300 5.2.4 DCL-60-1( ) (BK) CONSOLE/DCL-60-1( ) (WH) CONSOLE The Attendant Console has 60 programmable line keys and is available in black or white. The unit features: 60 programmable Direct Station Selection (DSS) keys (Refer to system user guides).
  • Page 417: Figure 7-67 Remove Side Panel From Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Pry the side panel from the multiline terminal. Side Panel Figure 7-67 Remove Side Panel from Multiline Terminal Turn the multiline terminal button side up. Fit the projections of the supplied bracket into the side of the multiline terminal.
  • Page 418: Figure 7-69 Press Serial Cable Into Groove

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Carefully push the Serial cable into the Serial Cable Groove (ITL, DT700 only). Figure 7-69 Press Serial Cable into Groove Using the guides, slide the DCL-60-1( ) onto the installed bracket (refer to Figure 7-69 Press Serial Cable into Groove).
  • Page 419: Figure 7-71 Serial Cable Installed

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect the cable from the DCL-60-1 CONSOLE to the Side Option Connector on the multiline terminal and close the cover (ITL, DT700 only). Figure 7-71 Serial Cable Installed Set the height of the tilt leg on the multiline terminal to the desired height.
  • Page 420: Lcd (Bl)-L( ) (Bk) Unit/Lcd (Bl)-L( ) (Wh) Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connect the AC Adapter cable (DT300/DT700 Series) See Figure 7-72 Connect AC Adapter Cable on page 7-58. Figure 7-72 Connect AC Adapter Cable Complete the installation by reattaching both plastic panels to the front of the multiline terminal.
  • Page 421: Panel( )-L Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 5.2.6 PANEL( )-L UNIT Optional plastic color side panels that allow users to customize the ITL/DTL terminals. The following colors are available for the Base (all), VLCD (Value LCD) and SLCD (Sophi LCD) terminals: Silver (original)
  • Page 422: Figure 7-76 Attach The Wm-L( ) Unit To Wall

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Attach the WM-L( ) UNIT to the wall using four screws (refer to Figure 7-76 Attach the WM-L( ) UNIT to Wall). Figure 7-76 Attach the WM-L( ) UNIT to Wall Align the four cutouts with the four tabs on the WM-L( ) UNIT...
  • Page 423: Release The Wm-L( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Push down on telephone until the WM-L( ) UNIT snaps into place (refer to Figure 7-78 WM-L( ) UNIT Installed). Figure 7-78 WM-L( ) UNIT Installed 5.2.8 Release the WM-L( ) UNIT To release the telephone from the WM-L( ) UNIT, press the...
  • Page 424: Wm-L( ) Unit Attached To Wall Plate

    Issue No. 1.5 UNIVERGE SV8100/SV8300 5.2.9 WM-L( ) UNIT Attached to Wall Plate The WM-L( ) UNIT (Wall Mount Unit) is used to attach any DT300/ DT700 Series multiline terminal to the wall plate This unit connects to the back side of the telephone.
  • Page 425: Figure 7-81 Cutouts For Wm-L( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Align the four cutouts with the four tabs on the WM-L( ) UNIT (refer to Figure 7-81 Cutouts for WM-L( ) UNIT on page 7-63). Figure 7-81 Cutouts for WM-L( ) UNIT Push up on the WM-L( ) UNIT until it snaps into place (refer to Figure 7-82 WM-L( ) UNIT Installed).
  • Page 426: Removing The Multiline Terminal From The Wall Mounted Plate

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Align the two holes on the back of the WM-L( ) UNIT with the two screws on the wall plate and slide downward (refer to Figure 7-83 Mount Multiline Terminal Wall on Wall Plate). Figure 7-83 Mount Multiline Terminal Wall on Wall Plate Because of strength variation in wall plates, this method is not recommended.
  • Page 427: Optional Handsets

    Using the PTM handset on an NEC digital or IP terminal prevents eavesdropping and eliminates the worry that privileged information could be transmitted without user authority. These handsets are also an ideal solution to filter unwanted audio transmissions from environments with ambient background noise.
  • Page 428: Utr-1-1( ) Usb Handset

    UNIVERGE SV8100/SV8300 UTR-1-1( ) USB Handset The NEC USB telephone can be plugged directly into a PC USB port, enabling the high quality voice input and output capabilities of a standard desktop telephone. By connecting it to the USB port of a computer, calls can immediately be made and received using a SoftPhone without installation of additional software drivers.
  • Page 429: Wall Mounting

    UNIVERGE SV8100/SV8300 Issue No. 1.5 6.3.3 Wall Mounting The UTR-1-1( ) USB handset can be mounted on the wall using a wall plate or two screws. Align the two holes on the back of the UTR-1-1( ) and slide down onto the wall plate or screws.
  • Page 430: Figure 7-90 Installing Slt Adapter

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connect one end of a second RJ-11 to the TEL jack on the SLT Adapter and the other end to the Single Line Telephone. SLT(1)-U( ) ADP RJ-11 RJ-11 2-wire 2-wire Figure 7-90 Installing SLT Adapter...
  • Page 431: Wall-Mounting The Slt Adapter

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Wall-Mounting the SLT Adapter Unplug the two line cords from the SLT Adapter. Remove the two screws from the front of the SLT Adapter. Lift the cover off the adapter. Figure 7-92 Removing the Cover Using the two screws provided with the SLT Adapter, attach the back cover to the desired location.
  • Page 432 Issue No. 1.5 UNIVERGE SV8100/SV8300 THIS PAGE INTENTIONALLY LEFT BLANK 7 - 70 Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals...
  • Page 433: Chapter 8 Installing Sv8100/Sv8300 Bluetooth

    Installing SV8100/SV8300 Bluetooth ENERAL ESCRIPTION ECTION This chapter provides information regarding the bluetooth telephone and adapter that can be used with the UNIVERGE SV8100/SV8300 system. LUETOOTH ORDLESS ANDSET ECTION Bluetooth Cordless Handset (BCH) Interface This optional interface allows the multiline terminal user to use Bluetooth technology to provide a cordless handset.
  • Page 434: Selecting A Location

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The BCH will retain call histories for up to 10 outgoing and 10 incoming calls. For outgoing calls, this would include completed and uncompleted calls. For incoming calls, this would include both answered and unanswered calls. The call history provides the date, time and telephone number for each call.
  • Page 435: Controls And Indicators

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Controls and Indicators Controls and indicators can be found in Figure 8-1 Bluetooth Cradle Controls and Indicators Figure 8-2 Bluetooth Handset Controls and Indicators on page 8-4. Figure 8-1 Bluetooth Cradle Controls and Indicators System Hardware Manual...
  • Page 436: Figure 8-2 Bluetooth Handset Controls And Indicators

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 8-2 Bluetooth Handset Controls and Indicators 8 - 4 Installing SV8100/SV8300 Cordless Telephones...
  • Page 437: Installing The Bluetooth Cordless Handset

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Installing the Bluetooth Cordless Handset The BCH-L (BK) UNIT is an optional device that transforms the standard multifunctional telephone into a cordless terminal. This section explains how to transform the standard hand-set into a BCH-L (BK) UNIT. The BCH-L (BK) UNIT cannot be connected to the DTL-2E-1 or DTL-6DE-1 telephones.
  • Page 438: Figure 8-4 Remove Legs From Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 8-4 Remove Legs From Multiline Terminal Remove the side panel. Disconnect serial connection cord from terminal body. Leave cord connected to the cradle unit. Push the latch to the right to unlock the cradle unit. Then push...
  • Page 439: Figure 8-6 Attach Bluetooth Cradle To The Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Insert the cradle connecting cable of the Bluetooth Cradle (BTC) into the unit connector. Figure 8-6 Attach Bluetooth Cradle to the Multiline Terminal Fit the projections on the side of the Bluetooth Cradle into the...
  • Page 440: Figure 8-8 Removing The Connector Cover

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove the connector cover (rubber) from the bottom of the multiline terminal. Figure 8-8 Removing the Connector Cover Insert the lower claws of the Bottom Unit (see Figure 8-9 Installing the Bottom Unit) into precut holes on the multiline terminal.
  • Page 441: Figure 8-10 Stowing The Bottom Unit Cable

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Push the latch to release the cover (see Figure 8-10 Stowing the Bottom Unit Cable). Stow the extra bottom unit connecting cable and close the cover. Figure 8-10 Stowing the Bottom Unit Cable Cut or trim the supplied coupled device for the tilt legs handset option.
  • Page 442: Wall Mounting The Bluetooth Cradle

    2.4.2 Wall Mounting the Bluetooth Cradle To prevent possible damage to the BCH-L (BK) UNIT due to falling, NEC recommends installing the unit in a firm position so it will not fall due to its own weight. 8 - 10...
  • Page 443: Figure 8-13 Wall Mount Spacing Guide Bch-L (Bk) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Clearances required for installing the Bluetooth cradle are shown below. Avoid mounting the cradle on a plaster-board wall, but before mounting the cradle on a wall, check that the wall can withstand the weight of the telephone and the load from pulling the telephone during operation.
  • Page 444: Figure 8-15 Change Handset Hanger

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove the Bluetooth hanger from the cradle. With a screwdriver, pry from the bottom, and lift the handset hanger from the cradle. Rotate the hanger top to bottom. Slide it downward in the hollow until it clicks into position.
  • Page 445: Remove And Replace Handset Battery

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Hook the wall mount holes (C and D) on the back of the terminal on wood screws (c and d) installed. Figure 8-17 Wall Mounting the Terminal 2.4.3 Remove and Replace Handset Battery The battery loaded in the Bluetooth handset has a useful life of about two years, depending on how the handset is used.
  • Page 446: Bluetooth Hub Adapter

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove existing battery and dispose of properly. Figure 8-19 Removing Battery from Handset Install new Li-ion battery. Full charge takes approximately 16 hours. Reinstall battery cover. LUETOOTH DAPTER ECTION Bluetooth Hub Adapter (BHA) Features The BHA-L UNIT adapter connects a Bluetooth device to a multiline terminal.
  • Page 447: Figure 8-20 Separate Tilt Leg From Leg Support

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Lower the tilt leg to the first position (refer to Figure 8-20 Separate Tilt Leg from Leg Support). Stoppers Tilt Leg Figure 8-20 Separate Tilt Leg from Leg Support Remove the connector cover (rubber) from the bottom of the...
  • Page 448: Pairing A Bluetooth Device And Multiline Terminal (Bluetooth Installed)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Insert the lower claws of the Bottom Unit (see Figure 8-22 Installing the BHA-L UNIT) into precut holes on the multiline terminal. Figure 8-22 Installing the BHA-L UNIT Align connector on inside of BHA-L UNIT and push down until unit snaps into place.
  • Page 449: Figure 8-24 Pairing A Device

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.1.2.3 Pairing Up to eight Bluetooth devices can be located around the BHA-L UNIT, select which can be paired with the device (refer to Figure 8-24 Pairing a Device on page 8-17). Figure 8-24 Pairing a Device 3.1.2.4 Connecting the Paired Device...
  • Page 450: Figure 8-27 Setting Visibility Option

    Issue No. 1.5 UNIVERGE SV8100/SV8300 3.1.2.6 Visibility Setting Set whether to make information about the BHA-L UNIT visible to other Bluetooth devices (default: [1. Disable]). Figure 8-27 Setting Visibility Option 3.1.2.7 BT Information You can view the following kinds of information about the BHA-L UNIT: Firmware and hardware versions.
  • Page 451: Chapter 9 Installing Sv8100/Sv8300 Wireless Telephones

    ECTION The implementation of SIP Digital Enhanced Cordless Telecommunication (DECT) in a NEC Telephone System is a stand-alone DECT system that is connected to the NEC Telephone System via a TCP/IP connection using Session Initiation Protocol (SIP). This means that in the NEC Telephone System, the DECT extensions must be assigned as SIP extensions.
  • Page 452: Installation

    Check that the lamp on the IP Switch indicates that the connection is established. (For UNIVERGE SV8100 only) Connect a network cable between the CD- (X)ILPA and the IP Switch. The next step is setting up your IP Addressing structure. Refer to the NEC SIP DECT Solutions Technician’s Guide, IP Addressing.
  • Page 453: Chapter 10 Installing Sv8100/Sv8300 Optional Equipment

    Installing SV8100/SV8300 Optional Equipment ENERAL NFORMATION ECTION This chapter provides information for installing optional equipment, such as term PGD(2)-U( ) ADPs, background music, door boxes, DSS consoles, D VSR, external paging as well as other handsets, recording devices and adapters on the SV8100/SV8300 digital and IP telephones. PGD(2)-U( ) ADP ECTION Using a PGD(2)-U( ) ADP...
  • Page 454: Led Indications

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The PGD(2)-U( ) ADP connects to any available digital extension port. The terminal connections made in the PGD(2)-U( ) ADP and the jumper settings determine what features are used for each circuit. Channel 2 Channel 1...
  • Page 455: Figure 10-3 Remove Plastic Cover From Cable Hole

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Using a screwdriver, break out the plastic piece covering the cable hole. Figure 10-3 Remove Plastic Cover from Cable Hole Set the S3 – S6 jumpers to the proper settings for the function to be used (refer to Table 10-2 PGD(2)-U( ) ADP S3 –...
  • Page 456: Figure 10-4 Pgd(2)-U( ) Adp Jumper Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 10-4 PGD(2)-U( ) ADP Jumper Settings Strip one end of the cable to be connected to the control relay or door box so that approximately 1/4” (8 mm) of bare wire is exposed. Insert the cable into the proper CN4 or CN5 location while holding down the lock button (holding down this lock button is easiest with a flat-head screwdriver).
  • Page 457: Figure 10-5 Pgd(2)-U( ) Adp Connection Diagram

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-5 PGD(2)-U( ) ADP Connection Diagram System Hardware Manual 10 - 5...
  • Page 458: Figure 10-6 Connecting Cable To The Pgd(2)-U( ) Adp

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Flat-head screwdriver Cable Press down CN4, CN5 Figure 10-6 Connecting Cable to the PGD(2)-U( ) ADP Repeat Steps 4 and 5 for any additional connection required. Replace the cover and tighten the screw to hold the cover in place.
  • Page 459: Figure 10-7 Pgd(2)-U( ) Adp Connections

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-7 PGD(2)-U( ) ADP Connections Install a modular jack for each PGD(2)-U( ) ADP. For each module, run one-pair 24 AWG station cable from the cross-connect block to a modular jack. Ground the unused pair.
  • Page 460: Figure 10-8 Installing The Screws

    Issue No. 1.5 UNIVERGE SV8100/SV8300 In some cases, when testing the operation of an extension port when connecting to a Cordless II, Cordless Lite II, or PGD(2)-U( ) ADP, a technician may connect a line cord directly from an extension port on the CD-8DLCA/CD-16DLCA Blade.
  • Page 461: Background Music

    UNIVERGE SV8100/SV8300 Issue No. 1.5 The back of the PGD(2)-U( ) ADP has two key-hole type openings. Place the PGD(2)-U( ) ADP over the two screws and slide it down or over (depending on the positioning) to lock it in place.
  • Page 462: Door Box

    Issue No. 1.5 UNIVERGE SV8100/SV8300 ECTION Installing a Door Box A PGD(2)-U( ) ADP is required for this option. The Door Box is a self-contained, water-resistant, Intercom unit typically used to monitor an entrance door. A visitor at the door can press the Door Box call button (like a door bell).
  • Page 463 UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect the two-conductor station cable from the CN4 connectors within the PGD(2)-U( ) ADP to the Door Box terminals. These wires must be routed through the opening in the bottom of the Door Box mounting bracket.
  • Page 464: Figure 10-11 Setting The Pgd(2)-U( ) Adp For A Door Box

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 10-11 Setting the PGD(2)-U( ) ADP for a Door Box 10 - 12 Installing SV8100/SV8300 Optional Equipment...
  • Page 465: Figure 10-12 Installing A Door Box

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-12 Installing a Door Box System Hardware Manual 10 - 13...
  • Page 466: External Paging

    Issue No. 1.5 UNIVERGE SV8100/SV8300 XTERNAL AGING ECTION External Page Two external page zone/door box circuits are provided by each PGD(2)-U( ) ADP installed. Each Door Box/external page circuit provides a dry relay contact. The CD-CP00-AU also provides a connection for external paging and a relay.
  • Page 467: Figure 10-13 Pgd(2)-U( ) Adp Cable Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect the two-conductor station cable from the CN5 connectors in the PGD(2)-U( ) ADP to the external relay/external page. Figure 10-13 PGD(2)-U( ) ADP Cable Connection he PGD(2)-U( ) ADP provides amplifiers for each page output port (for a maximum of +8 dBM, 600 ohms at 1KHz).
  • Page 468: External Paging And Door Box

    Issue No. 1.5 UNIVERGE SV8100/SV8300 XTERNAL AGING AND ELAYS ECTION External Page Relays Two external dry contact relays are available when a PGD(2)-U( ) ADP is installed which can be used to activate ancillary devices (i.e. door unlock devices). The CD-CP00-AU also provides one page relay. When the relay on the PGD(2)-U( ) ADP is used, there is no need to assign the relay to the Door Box –...
  • Page 469: Figure 10-14 Cd-Cp00-Au Page Connections

    UNIVERGE SV8100/SV8300 Issue No. 1.5 If a line cord was not previously connected to the PGD(2)-U( ) ADP, complete Steps 3-6. Otherwise, skip to Step 7. Install a modular jack for each PGD(2)-U( ) ADP. For each module, run one-pair 24 AWG station cable from the cross-connect block to a modular jack.
  • Page 470: External Recording System/External Ringer

    Issue No. 1.5 UNIVERGE SV8100/SV8300 XTERNAL ECORDING YSTEM XTERNAL INGER ECTION External Recording System or External Ringer The PGD(2)-U( ) ADP allows the connection of an external recording system or external ringer. With a customer-provided tape recorder, when an extension user dials the ACI analog port extension number, they can automatically start the recorder and activate the record function.
  • Page 471: Programming

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-15 PGD(2)-U( ) ADP Cable Connection Programming 10-03-01 : ETU Setup – Terminal Type (Circuit 1) 10-03-06 : ETU Setup – Terminal Type (Circuit 2) Confirm that the PGD(2)-U( ) ADP has defined the circuit type as either type 7 for External Ringer or 9 for ACIs.
  • Page 472 Issue No. 1.5 UNIVERGE SV8100/SV8300 11-12-50 : Service Code Setup (For Service Access) Specify the service code to be used to toggle the relay open and closed (Default: 780). 33-01-01 : ACI Port Type Setup Set each ACI software port for input (1) or input/output (2). Use input ports for Music on Hold sources.
  • Page 473: Music Sources

    UNIVERGE SV8100/SV8300 Issue No. 1.5 USIC OURCES ECTION Music on Hold The system can provide Music on Hold from either an internally synthesized source on the CD-CP00-AU or from an external source. The external MOH can be a tuner, tape deck, CD player, etc. The settings in Program 10-04-01 and 14-08-01 determine whether the source for MOH is internal or external.
  • Page 474: Figure 10-16 Cpru Connections

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install bridging clips as required. Plug a modular line cord from the mod jack to the CN1 connector on the PGD(2)-U( ) ADP. Connect an RCA jack to the audio output(s) on the back of the PGD(2)-U( ) ADP.
  • Page 475: Night Mode Selection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-17 PGD(2)-U( ) ADP Connections IGHT ELECTION ECTION Night Mode Selector Switch The Night Mode Switch relay closes when the system detects either an open or closure on the MISC block NIGHT SW terminals. Maximum 48v DC is output to the switch when open, and 7mA DC when shorted.
  • Page 476: Telephone Labeling

    Issue No. 1.5 UNIVERGE SV8100/SV8300 ELEPHONE ABELING ECTION 10.1 DESI Printer Sheets Telephones can be easily labeled by removing the plastic faceplate. These labels can be printed by hand, typewriter, or printing DESI labels. Labels for this are on 8 1/2 x 11” paper, which allows for easy printing by any printer – dot matrix, laser, etc.
  • Page 477: D Term ® Voice Security Recorder (Vsr)

    The D Voice Security Recorder is a USB device that taps across the digital extension pair of the NEC telephone system allowing digital recording of the telephone user’s conversation. The file created is saved either to the local PC or to a network location, depending on the application blade. This adapter is for use with digital multiline terminals.
  • Page 478: Installation

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Two digital telephone line connections that passively tap across term the D digital connection and listen in high impedance mode to the signaling on the line. CHS2U-AU Terminal Computer Figure 10-20 VSR Connection Configuration 11.3...
  • Page 479 Run the Setup.exe program file from the NEC installation CD BEFORE connecting the telephone interface unit to the PC. Using the USB cable provided, connect the USB interface of the NEC VSR unit to an available USB port on the PC.
  • Page 480: Figure 10-21 Voice Security Recorder Installation-1

    Issue No. 1.5 UNIVERGE SV8100/SV8300 For Windows 2000 or XP term Using the USB cable provided, connect the USB interface on the D unit to your PC. Windows will automatically detect the new hardware and start the New Hardware Wizard. This displays a dialog box similar to the one shown below.
  • Page 481: Figure 10-22 Voice Security Recorder Installation-2

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Insert the NEC Installation CD in your CD drive and press Next>. Figure 10-22 Voice Security Recorder Installation-2 If you downloaded the files from the internet, uncheck the Search removable media box, select the Include this location… box and enter the location where you stored the downloaded files (e.g.
  • Page 482: Vsr Application Software

    Voice Security Recorder application software on your PC. Using the USB cable provided, connect the USB interface of the NEC VSR unit to an available USB port on your PC. Unplug the line cord from your telephone and connect the phone to either...
  • Page 483: Vsr Playback Tab

    UNIVERGE SV8100/SV8300 Issue No. 1.5 File Management allows the user to manage disk space used by the VSR. Figure 10-24 VSR User Interface Tab Options 11.3.3 VSR Playback Tab This tab allows the user to list and play recorded conversations. A graphical presentation of the volume level of the call with a cursor to indicate the current playback position is displayed.
  • Page 484: Figure 10-26 Caller Id Or Comment Editor

    Caller ID and number dialed are not available on the first release. Check with NEC for release date. The user can list recordings in order of importance (using exclamation mark) with Caller ID, Time + Date, or duration.
  • Page 485: Vsr Record Tab

    UNIVERGE SV8100/SV8300 Issue No. 1.5 11.3.4 VSR Record Tab This tab allows the user to view recording levels and control the recording. Figure 10-27 View Levels and Control Recording The Oscilloscope shows the local and remote levels on the line separately (Microphone is the user level, and speaker is the distant party level).
  • Page 486: About Tab

    Issue No. 1.5 UNIVERGE SV8100/SV8300 11.3.5 About Tab This tab provides version and manufacturer information. Figure 10-28 VSR About Tab 10 - 34 Installing SV8100/SV8300 Optional Equipment...
  • Page 487: Options Tab

    UNIVERGE SV8100/SV8300 Issue No. 1.5 11.3.6 Options Tab This tab allows the user to select various setup options of the VSR. Figure 10-29 Select VSR Setup Options Automatically start recording every call Starts the recording when a call, including an internal extension call, is made.
  • Page 488: Figure 10-30 Manage Calls At Completion

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Show splash screen at startup When selected, the VSR logo is shown for five seconds when the application is started. Email format Allows the user to select the type of file inserted in an e-mail when...
  • Page 489: File Management Tab

    UNIVERGE SV8100/SV8300 Issue No. 1.5 11.3.7 File Management Tab File management is necessary when the user makes many telephone calls and stores each conversation. The selections are self- explanatory. Figure 10-31 File Management Tab 11.3.8 Custom Program Settings Comvurgent provides the dealer or user the option of making additional adjustments.
  • Page 490: Figure 10-33 Customizing Application To Meet Requirements

    This special configuration program can only be accessed by browsing to the installation location (default C:\Program term Files\Comvurgent\XtRecorder), and then click on the NEC D Config.exe. The customer takes all responsibility to ensure they meet legal requirements. Comvurgent provides the user option settings to meet customer demands and cannot be responsible for misapplication of the product.
  • Page 491: Operation Note

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Hide the system tray icon for invisible recording Hides the small icon that appears in the system tray and flashes red when recording. Password Locks access to these settings and those at the user level.
  • Page 492: 4-Port Digital Call Logging Unit

    Configuration. 11.5.3 Connectors The NEC 4-Port Digital Call Logging Unit USB recording device has five connectors and four LED indicators: One PC USB connector, from which the device derives its power and streams all speech and control channel information up to the host PC and NEC BackOffice application.
  • Page 493: Package Contents

    Installation 11.5.6.1 Location Preparation The wiring for the extensions should be within six feet of the PC location. For this reason, the PC for the NEC BackOffice Recorder should be located near the MDF for extension wiring. System Hardware Manual...
  • Page 494 Issue No. 1.5 UNIVERGE SV8100/SV8300 DO NOT install the NEC BackOffice Software until instructed! It is critical that you follow the steps in the installation procedure in the order listed below. Failure to do so will result in an unsuccessful installation.
  • Page 495: Figure 10-36 Digital Station Ports

    USB cable and plug the USB cable into the PC. Windows responds with the Found New Hardware wizard. Insert the provided NEC BackOffice CD into the CD drive of the PC. Direct the installation of the driver to Specific Location and specify the Driver folder on the CD.
  • Page 496: Figure 10-37 Recorder Screen

    Issue No. 1.5 UNIVERGE SV8100/SV8300 11.5.6.4 Install the 4-Port Digital Call Logging Unit BackOffice Software Insert the NEC BackOffice CD into the CD drive of the PC. Locate the Recorder folder. Click on the Setup.exe file in the Recorder folder.
  • Page 497: Figure 10-38 Enter Line Details Dialog Box

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Double click on the first line in the sequence to configure. The Enter Line Details dialog box is displayed (each device is identified with a unique serial number – followed by a 1, 2, 3 or 4 which identifies the port from left to right on the device).
  • Page 498: Figure 10-39 Recorder Screen

    File then Exit from the Recorder screen menu to save your configuration. The NEC Recorder now records every call to and from the telephones. It is important to use proper procedure to shut down the application and PC when necessary.
  • Page 499 UNIVERGE SV8100/SV8300 Issue No. 1.5 11.5.6.5 Choose and Install Player Options There are several player options available with the NEC BackOffice Recording solution. Desktop Player – can be loaded on an individual user’s PC, giving the user complete access (although restrictions can be applied) to call management;...
  • Page 500: Vsr Manager Version 2.0 Installation

    Desktop Player which is designed to be used by an individual user to play term back their own archive of calls or to play back NEC D VSR calls stored on their PC or network. It is designed to easily manage calls from one storage location.
  • Page 501: Hardware And Software Check For Vsr Manager 2.0

    UNIVERGE SV8100/SV8300 Issue No. 1.5 VSR Manager allows the manager or supervisor to quickly and easily gain access to important calls. Figure 10-41 VSR Manager Screen These two players can be combined in any number of configurations in the company, providing control and management where needed and simple playback in other locations.
  • Page 502 Windows 2000 (recommended latest service pack) Windows 2003 Microsoft .Net Framework 1.1+ If your PC does not meet the above requirements, please contact NEC. VSR Manager 2.0 can be provided if upgrading to the minimum requirements is not possible or desirable 11.6.1.3 Screen Resolution...
  • Page 503: Install Your Application Security Key

    UNIVERGE SV8100/SV8300 Issue No. 1.5 11.6.2 Install Your Application Security Key VSR Manager requires an Application Security Key (a USB dongle which is shipped with the application) to be inserted when the VSR Manager is running. This unlocks the application and prevents unauthorized use.
  • Page 504: Vsr Reporter Pro 2.0 Installation

    Desktop Player which is used by an individual user to play back their own term archive of calls or to play back NEC D VSR calls stored on their PC or network. It is designed to easily manage calls from one storage location. It does...
  • Page 505: Figure 10-43 Vsr Reporter Pro Screen

    Issue No. 1.5 The second player option is the VSR Reporter Pro. Take your call recording environment to the next level with NEC VSR application software. VSR Reporter Pro provides advanced visibility, access, retrieval, and playback tools for the VSR Recorder administrators. It provides an intuitive interface for...
  • Page 506: Hardware And Software Check For Vsr Reporter Pro 2.0

    Windows 2000 (recommended latest service pack) Windows 2003 Microsoft .Net Framework 1.1+ If your PC does not meet the above requirements, please contact NEC. VSR Reporter Pro 2.0 can be provided if upgrading to the minimum requirements is not possible or desirable 11.7.1.3 Screen Resolution...
  • Page 507: Install Your Application Security Key

    UNIVERGE SV8100/SV8300 Issue No. 1.5 If the Microsoft .Net Framework 1.1 is not installed, you can download it from the Microsoft web site. The link to Microsoft .Net Framework download at time of this writing: http://www.microsoft.com/downloads/ details.aspx?FamilyID=262d25e3-f589-4842-8157- 034d1e7cf3a3&displaylang=en Not sure if .Net is installed: If you have any doubts, try to install VSR Reporter Pro 2.0.
  • Page 508: Using Adapters

    Issue No. 1.5 UNIVERGE SV8100/SV8300 11.7.3.1 Install VSR Reporter Pro Insert the VSR Reporter Pro CD into the computer CD-ROM drive or navigate to the location where you have saved your application download. Double-click the VSR Reporter Pro Set-up icon.
  • Page 509: In-Line Power Adapter (Ilpa-R( ))

    The ILPA does the negotiation and detection with the switch and then relays the power to the IP terminal device. This provides an additional way to power the NEC IP terminals. With this adapter, the IP terminals on the UNIVERGE SV8100/SV8300 system can be powered using:...
  • Page 510: Installation

    SW1 Setting IEEE802.3af STD System Cisco Discovery Protocol System NEC BlueFire 200/24 Switch Set the switch setting on the NEC IPhone or IP adapter to the correct position. IPhone (SW2) or IP Adapter (SW1) SW Setting NEC Power Patch Panel...
  • Page 511: Ada-L( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Connect the NEC VoIP telephone to the TEL connector on the ILPA-R( ) adapter with the LAN cable provided with the adapter. If a customer-provided cable is used, the total length from the switch to the telephone should be less than 328 feet.
  • Page 512: Ada-L( ) Unit Switch Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Before installing or removing the adapters, the multiline terminal should be unplugged from the system. Be sure the connected audio device provides a standard AUX level input. The use of monitoring, recording, or listening devices to...
  • Page 513: Table 10-3 Ada-L( ) Unit Switch Settings

    UNIVERGE SV8100/SV8300 Issue No. 1.5 To provide control to the recorder or to enable/disable the record start warning tones, refer to Table 10-3 ADA-L( ) Unit Switch Settings. Table 10-3 ADA-L( ) Unit Switch Settings Switch Description/Settings Record Confirmation Tone...
  • Page 514: Figure 10-49 Separate Tilt Leg From Leg Support

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Lower the tilt leg to the first position (refer to Figure 10-49 Separate Tilt Leg from Leg Support). Stoppers Tilt Leg Figure 10-49 Separate Tilt Leg from Leg Support Push the two stopper tabs through the slots to separate the tilt leg from the leg support.
  • Page 515: Ada-L( ) Unit Connection

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Return tilt leg to original position. Reconnect all cables previously disconnected. 12.3.3 ADA-L( ) Unit Connection The mini-plug connection cord should not use an attenuator and have a monaural (single ring) mini-plug connection for normal recording.
  • Page 516: Apr-L( ) Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Using the mini-plug connection cord, connect the the ADA-L( ) Unit IN jack to the cassette recorder EAR PHONE jack (Refer to Figure 10-53 ADA-L( ) IN Jack Connection). 03.5 stereo mini-plug ↔ 03.5 stereo mini-plug Figure 10-53 ADA-L( ) IN Jack Connection 12.4...
  • Page 517: Installing The Apr-L( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 ANALOG PORT 1 ~ 5, 7, 8 = Off 6 = On Figure 10-54 APR-L( ) UNIT Set the dip switches on the APR adapter to the required position. 12.4.2 Installing the APR-L( ) UNIT Perform the following to connect the APR-L( ) UNIT to the Bottom Option Interface located underneath the DTL multiline terminal.
  • Page 518: Figure 10-56 Bottom Option Interface Knockout

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Carefully pry loose the knockout covering the bottom option interface (refer to Figure 10-56 Bottom Option Interface Knockout on page 10-66). Bottom Option Knockout Interface Figure 10-56 Bottom Option Interface Knockout Using the exposed Bottom Option Interface as a guide, install the APR-L( ) UNIT in the bottom of the DTL multiline terminal.
  • Page 519: Psa-L( ) (Bk) Unit / Psa-L( ) (Wh) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 To determine the APR analog extension number 10-03-04 : Optional Installed Unit 1 Displays the type of terminal installed. This can be used to verify that the system recognizes the adapter. 10-03-06 : Blade Setup Assign the terminal type (12) for the telephone channel, which has the APR Adapter installed.
  • Page 520: Figure 10-59 Psa-L Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Dial method – MF/DF (10pps) PSTN User System/PSTN Switch Volume Control Figure 10-59 PSA-L UNIT PSTN DTMF/DP Figure 10-60 PSA-L UNIT Connections 10 - 68 Installing SV8100/SV8300 Optional Equipment...
  • Page 521: Installing The Psa-L( ) Adapter

    UNIVERGE SV8100/SV8300 Issue No. 1.5 12.5.1 Installing the PSA-L( ) Adapter Before installing or removing the PSA-L( ) adapter, remove the line cord, LAN cable, and then AC adapter from the outlet. Turn the multiline terminal upside down. Unplug the line cord and handset cord from the multiline terminal.
  • Page 522: Figure 10-62 Remove Legs From Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Press the two tabs locking the legs to the multiline terminal and pull the legs toward you, lifting to remove. Figure 10-62 Remove Legs From Multiline Terminal Disconnect serial connection cord from terminal body. Leave cord connected to the cradle unit.
  • Page 523: Figure 10-64 Attach Psa-L( ) Unit To The Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Fit the projections on the side of the PSA-L UNIT into the guide holes on the side of the terminal and pull toward you until the PSA-L UNIT snaps into place. Figure 10-64 Attach PSA-L( ) Unit to the Multiline Terminal Gently press the serial cable into the grooved cutout for the cable.
  • Page 524: Figure 10-66 Insert Stopper For Handset Use

    Issue No. 1.5 UNIVERGE SV8100/SV8300 If using the handset, place the stopper in the tilt leg. Figure 10-66 Insert Stopper for Handset Use For the Handset, set the connector in place. Figure 10-67 Insert Connector for Handset Use Attach the analog trunk cable and the handset cable. Refer to Figure 10-60 PSA-L UNIT Connections on page 10-68.
  • Page 525: Figure 10-68 Remove Plastic Panels

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Remove both plastic panels from the front of the multiline terminal. Figure 10-68 Remove Plastic Panels Pull tab down and lift out the numbered keypad panel. Figure 10-69 Remove Numbered Keypad Install the new keypad panel supplied with the PSA-L UNIT.
  • Page 526: Using The Psa-L( ) Adapter

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Reinstall both plastic panels to the front of the multiline terminal (refer to Figure 10-71 Install Plastic Panels on page 10-74). Figure 10-71 Install Plastic Panels Connect the line cord to the adapter. Connect the user system (KTS or PBX) cable.
  • Page 527: Power Failure Telephones

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Adjusting the Ring Volume Use the Volume Control Switch located on the PSA-L( ) adapter to adjust through the three available volume levels. Other than receiving calls, no other terminal functions are available. When Power is Restored The IP multiline terminal restarts and reconnects to the network LAN.
  • Page 528: Connector Pin-Outs On Coiu Blade For Power Failure Circuits

    Issue No. 1.5 UNIVERGE SV8100/SV8300 13.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits Table 10-4 RJ-61 Cable Connector RJ-61 Cable Connector - CN13, SLT Interface for Power Failure Pin No. Connection – – Circuit 2 - Tip Circuit 1 - Ring...
  • Page 529: Figure 10-72 Power Failure Connector (Cn3) Shown On Cd-4Cotb Blade

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 10-72 Power Failure Connector (CN3) Shown on CD-4COTB Blade System Hardware Manual 10 - 77...
  • Page 530 Issue No. 1.5 UNIVERGE SV8100/SV8300 THIS PAGE INTENTIONALLY LEFT BLANK 10 - 78 Installing SV8100/SV8300 Optional Equipment...
  • Page 531: Chapter 11 Installing D Term Series I Telephones

    term Installing D Series i Telephones ENERAL NFORMATION ECTION term The SV8100/SV8300 system supports several different IPK II D Series i multiline terminals and an Attendant Console. This chapter describes each terminal and the console and provides instructions for attaching the terminals to the system and for wall mounting.
  • Page 532: Dtr-4D-1( ) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Figure 11-1 DTR-2DT-1( ) TEL DTR-4D-1( ) TEL This digital display multiline terminal has four multifunction keys, four programmable line keys (each with a 2-color LED), nine function keys, two volume keys, four Softkeys, a built-in speakerphone, and a large LED to indicate incoming calls and messages.
  • Page 533: Dth-8-1( )/2( ) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 DTH-8-1( )/2( ) TEL This digital nondisplay multiline terminal has eight programmable line keys (each with a 2-color LED), a built-in speakerphone, headset jack, a large LED to indicate incoming calls and messages, and compatibility with AD(A)-R( ), AP(A)-R( ), AP(R)-R( ), CT(A)-R( ), CT(U)-R( ), or HF-R( ), Unit.
  • Page 534: Dth-16-1( )/2( ) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The DTR-8D-1( )/2( ) TEL is similar to the DTH-8D-1( )/2( ) TEL and can be also used with the SV8100/SV8300 system. Figure 11-4 DTH-8D-1( ) TEL Multiline Terminal DTH-16-1( )/2( ) TEL This digital nondisplay multiline terminal has 16 programmable line keys (each...
  • Page 535: Dth-16D-1( )/2( ) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 DTH-16D-1( )/2( ) TEL This digital multiline terminal has 16 programmable line keys (each with a 2-color LED), a built-in speakerphone, headset jack, a large LED to indicate incoming calls and messages, and compatibility with AD(A)-R( ), AP(A)-R( ), AP(R)-R( ), CT(A)-R( ), CT(U)-R( ), HF-R( ), or IP-R( ) Unit.
  • Page 536: Dth-16Ld-1( )/2( ) Tel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 The DTR-16(BL)-1( )/2( ) TEL is similar to the DTH-16(BL)-1( )/2( ) TEL and can be used also with the SV8100/SV8300 system. Figure 11-7 DTH-16(BL)-1( ) TEL Multiline Terminal DTH-16LD-1( )/2( ) TEL This digital multiline terminal has 16 programmable line keys, a built-in...
  • Page 537: Dth-32D-1( ) Tel

    UNIVERGE SV8100/SV8300 Issue No. 1.5 The DTR-16LD-1( )/2( ) TEL is similar to the DTH-16LD-1( )/2( ) TEL and can be used also with the SV8100/SV8300 system. Figure 11-8 DTH-16LD-1( ) TEL Multiline Terminal DTH-32D-1( ) TEL This digital multiline terminal has 32 programmable line keys (each with a...
  • Page 538: Dcr-60-1( ) Console

    Issue No. 1.5 UNIVERGE SV8100/SV8300 2.10 DCR-60-1( ) Console The Attendant Console has 115 programmable line keys (each with a 2-color LED). An AC adapter is required and provided with the Attendant Console. Figure 11-10 DCR-60-1( ) Console ONNECTING A...
  • Page 539: Figure 11-12 Leading Line Cords On A Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Lead the telephone and handset cords through the applicable grooves. Figure 11-12 Leading Line Cords on a Multiline Terminal ONNECTING THE TTENDANT ONSOLE TO A ULTILINE ECTION ERMINAL An Attendant DCR-60-1( ) Console can be attached to a multiline terminal using the following procedure.
  • Page 540: Figure 11-14 Connecting The Line Cord And Ac Adapter When Installing A Dcr Attendant Console

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Connect the line cord and the AC adapter to the indicated locations on the bottom of the Attendant Console. Line Cord Jack AC Adapter Plug Figure 11-14 Connecting the Line Cord and AC Adapter when Installing a DCR...
  • Page 541: Installing Line Cards And Plastic Panels

    UNIVERGE SV8100/SV8300 Issue No. 1.5 DJUSTING THE ON A ULTILINE ERMINAL ECTION The SV8100/SV8300 display multiline terminals have an adjustable Liquid Crystal Display (LCD). The LCD can be adjusted by pulling up or pushing down as desired. Figure 11-16 Adjusting the LCD on a Multiline Terminal...
  • Page 542: Removing The Plastic Panel

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Place the plastic panel over the line card and push the corners of the plastic panel until they click into place. Plastic Panel Multiline Terminal Figure 11-18 Installing Plastic Panel on a DTH/DTR Multiline Terminal...
  • Page 543: Figure 11-20 Attaching Directory Card To Directory Card Holder

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Note that the open end slides into the directory card holder. Directory Card Directory Card Holder Figure 11-20 Attaching Directory Card to Directory Card Holder Locate the two grooves on the top of themultiline terminal as illustrated in...
  • Page 544: Figure 11-22 Removing The Button Set From A Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 NSTALLING A UTTON ET ON A ULTILINE ERMINAL ECTION The BS( )-R( ) Unit button set can be installed on a multiline terminal to accommodate French and Spanish languages. The keypad provides the appropriate language designations.
  • Page 545: Removing The Base Plate

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Grasp in the middle of the hollow spaces at the top and pull up until the retaining tabs click to raise the base plate. Refer to Figure 11-24 Raising the Height on the DTH/DTR Multiline Terminal.
  • Page 546: Installing The Base Plate

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Press the tabs as illustrated in Figure 11-26 Removing Base Plate, and slide the base cover in the direction of the arrows until it clicks. Figure 11-26 Removing Base Plate 10.2 Installing the Base Plate...
  • Page 547: Wall Mounting A Multiline Terminal Using The Base Plate

    UNIVERGE SV8100/SV8300 Issue No. 1.5 11.1 Wall Mounting a Multiline Terminal using the Base Plate 11.1.1 Adjusting the Hanger Hook Remove the hook from the unit. Hanger Hook Figure 11-28 Removing the Hanger Hook on a Multiline Terminal Turn the hook with the tab toward the top.
  • Page 548: Figure 11-30 Removing The Cutout

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Remove cutout shown in Figure 11-30 Removing the Cutout. Figure 11-30 Removing the Cutout Plug line cord in the wall receptacle. Leave about eight inches of cord and bundle the rest as shown in Figure 11-31 Bundling the Line Cord.
  • Page 549: Figure 11-32 Wall Mounting The Base Plate

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Turn the base cover upside down, feed the line cord through the cutout and attach the cover to the wall using six screws as shown in Figure 11-32 Wall Mounting the Base Plate. Figure 11-32 Wall Mounting the Base Plate Install the multiline terminal over the four tabs on the base cover, and push down until it clicks in place.
  • Page 550: Removing The Wall Mounted Multiline Terminal From The Base Plate

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the line cord into the multiline terminal as illustrated in Figure 11-34 Plugging in Line Cord into Multiline Terminal. Figure 11-34 Plugging in Line Cord into Multiline Terminal Push spare line cord behind the multiline terminal as shown in Figure 11-35 Hiding Excess Cord.
  • Page 551: Wall Mounting The Base Plate On A Wall Plate

    UNIVERGE SV8100/SV8300 Issue No. 1.5 To remove the multiline terminal, press the tabs at the bottom as shown in Figure 11-36 Removing the Multiline Terminal, and push up on the Telephone until it comes loose. Figure 11-36 Removing the Multiline Terminal 11.1.4...
  • Page 552: (Wm-R( ) Unit)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Hang the multiline terminal on the base cover. Figure 11-38 Wall Mounted Multiline Terminal Because of strength variation in swall plates, this method is not recommended. OUNTING A ULTILINE ERMINAL USING THE OUNT ECTION (WM-R( ) U The Wall Mount Unit is used to attach any DTH/DTR connection multiline terminal (except the DTR-2DT-1( ) TEL) to the wall.
  • Page 553: Figure 11-39 Attaching The Wall Mount Unit To The Wall

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Attach the WM-R( ) Unit using six screws. Figure 11-39 Attaching the Wall Mount Unit to the Wall Install the multiline terminal over the four tabs on the base cover, and push down until it clicks in place as illustrated in...
  • Page 554: Removing The Wall Mounted Multiline Terminal From The Wall Mount Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the line cord into the multiline terminal as illustrated in Figure 11-41 Plugging in Line Cord. Figure 11-41 Plugging in Line Cord Push spare line cord behind the multiline terminal as shown in Figure 11-42 Hiding Excess Cord Behind the Wall Mount Unit.
  • Page 555: Mounting The Wall Mount Unit On A Wall Plate

    UNIVERGE SV8100/SV8300 Issue No. 1.5 To remove the multiline terminal, press the tabs at the bottom as shown in Figure 11-43 Removing Multiline Terminal from the Wall Mount Unit, and push up on the multiline terminal until it comes loose.
  • Page 556: Figure 11-45 Wall Mounted Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Hang the multiline terminal on the base cover. Figure 11-45 Wall Mounted Multiline Terminal term 11 - 26 Installing D Series i Telephones...
  • Page 557: Chapter 12 Installing D Term Series I Optional Equipment

    term Installing D Series i Optional Equipment ENERAL NFORMATION ECTION The SV8100/SV8300 system provides several adapters that allow term peripheral equipment to be attached to the IPK II D Series i multiline terminals. This optional equipment enhances the SV8100/SV8300 system and can be purchased separately as a customer business grows.
  • Page 558: Figure 12-2 Removing The Multiline Terminal Base Plate

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Press down on the tabs indicated in Figure 12-2 Removing the Multiline Terminal Base Plate, and push forward on the base plate to remove it. Figure 12-2 Removing the Multiline Terminal Base Plate When an adapter is installed for the first time, the base cover on the multiline terminal must be modified.
  • Page 559: Preparing Multiline Terminal For Adapter Installation

    UNIVERGE SV8100/SV8300 Issue No. 1.5 NSTALLING DAPTERS ECTION AC-2R/AC-3R Unit (AC Adapter) This unit shown in Figure 12-4 AC-2R/AC-3R Unit (AC Adapter) provides power to ancillary devices or to an Attendant Console. The AC-2R/AC-3R Unit must be connected to some adapters that are installed on a multiline terminal. When more than one adapter is installed on a multiline terminal, only one AC-2R/AC- 3R Unit is necessary.
  • Page 560: Ad(A)-R( ) Unit (Ancillary Device Adapter)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Locate the plug on the ancillary device that is connected to the bottom of the multiline terminal and plug in the AC Adapter. Figure 12-5 Connecting the AC Adapter to an Installed Adapter AD(A)-R( ) Unit (Ancillary Device Adapter)
  • Page 561: Connecting Cables To The Ad(A)-R( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 12-7 Connecting a Multiline Terminal to a Recording Device using an AD(A)-R( ) Unit (Example) illustrates how the AD(A)-R( ) Unit is connected to the ESI(8)-U( ) ETU and to the recording device. Multiline Terminal + AD(A)-R( ) Unit...
  • Page 562: Figure 12-10 Removing Ad(A)-R( ) Unit Cover

    Issue No. 1.5 UNIVERGE SV8100/SV8300 To connect the cables: Cut off the plug on one end of the cable. Remove the screw as illustrated in Figure 12-10 Removing AD(A)-R( ) Unit Cover on page 12-6 and open the unit cover.
  • Page 563: Table 12-1 Ad(A)-R( ) Unit Cable Connections

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Table 12-1 AD(A)-R( ) Unit Cable Connections Terminal Cables to Connect Terminal Specifications Number When warning tone is not being sent from the Input Terminal: T1 and T2 are enabled for tone recorder, connect wire pair input from tone generating device when switches SW1-3 and generator to T1:T2.
  • Page 564: Switch Settings

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Feed the installed cable through the cable access port, located on the back of the unit, as illustrated in Figure 12-12 AD(A)-R( ) Unit Cable Access Port. Cable Access Port Cable Figure 12-12 AD(A)-R( ) Unit Cable Access Port 3.2.2...
  • Page 565: Table 12-2 Ad(A)-R( ) Unit Switch Settings

    UNIVERGE SV8100/SV8300 Issue No. 1.5 To provide control to the recorder or to enable/disable the record start warning tones, refer to Table 12-2 AD(A)-R( ) Unit Switch Settings. Table 12-2 AD(A)-R( ) Unit Switch Settings Switch Description/Settings SW1-1 Connects to multiline terminal...
  • Page 566: Figure 12-14 Attaching The Ad(A)-R( ) Unit To The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the tabs marked A and B into adapter slots, then snap the tab on the other end of the adapter into the receptacle marked C. Refer to Figure 12-14 Attaching the AD(A)-R( ) Unit to the Multiline Terminal on page 12-10.
  • Page 567: Ap(A)-R( ) Unit/Ap(R)-R( ) Unit (Port Adapter)

    UNIVERGE SV8100/SV8300 Issue No. 1.5 AP(A)-R( ) Unit/AP(R)-R( ) Unit (Port Adapter) The AP(A)-R( ) Unit Analog Port Adapter without Ringer or the AP(R)-R( ) Unit Analog Port Adapter with Ringer is used to install a single line telephone, modem, credit card reader, wireless headset, or other compatible analog device.
  • Page 568: Installing Ap(A)-R( ) Or Ap(R)-R( ) Unit On A Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Table 12-3 AP(A)-R( )/AP(R)-R( ) Unit Switch Settings Switch Description/Settings SW1-1 Connects to multiline terminal (default). SW1-2 Not Used Ω SW3-1 Sets impedance to 600 for devices such as modems or facsimile machines. SW3-2 Used for complex impedance devices such as single line telephones.
  • Page 569: Figure 12-17 Attaching The Ap(A)-R( )/Ap(R)-R( ) Unit To The Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 12-17 Attaching the AP(A)-R( )/AP(R)-R( ) Unit to the Multiline Terminal System Hardware Manual 12 - 13...
  • Page 570: Ct(A)-R( ) Unit (Computer Telephony Adapter)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the ferrite core (provided with the unit) about two inches from the line cord plug. AP(A)-R( ) Unit AP(R)-R( ) Unit Figure 12-18 Installing the Ferrite Core on the AP(A)-R( )/AP(R)-R( ) Unit Connect the line cord to the unit, limiting the cable length from the AP(A)/AP(R)-R( ) Unit to the single line telephone to a maximum of 50 feet.
  • Page 571: Installing The Ct(A)-R( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 12-20 Connecting a Multiline Terminal to a PC using a CT(A)-R( ) Unit (Example) shows how the CT(A)-R( ) Unit is connected to the ESI(8)-U( ) ETU and to the PC. The required AC-2R/AC-3R Unit adapter is not shown.
  • Page 572: Figure 12-21 Attaching The Ct(A)-R( ) Unit To The Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the tabs marked A and B into adapter slots, then snap the tab on the other end of the adapter into the receptacle marked C. Refer to Figure 12-21 Attaching the CT(A)-R( ) Unit to the Terminal on page 12-16.
  • Page 573: Connecting The Ct(A)-R( ) Unit To The Pc

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.4.2 Connecting the CT(A)-R( ) Unit to the PC Connect RS-232C cable from the PC to the CT(A)-R( ) Unit as shown Figure 12-22 Connecting the RS-232C Cable to the CT(A)-R( ) Unit. Figure 12-22 Connecting the RS-232C Cable to the CT(A)-R( ) Unit 3.4.3...
  • Page 574: Ct(U)-R( ) Unit (Computer Telephony Adapter)

    Issue No. 1.5 UNIVERGE SV8100/SV8300 CT(U)-R( ) Unit (Computer Telephony Adapter) The CT(U)-R( ) Unit Computer Telephony Adapter allows a multiline terminal to be connected to a PC using the PC USB port. Connecting using the USB port provides telephony and sound device control.
  • Page 575: Installing The Ct(U)-R( ) Unit

    UNIVERGE SV8100/SV8300 Issue No. 1.5 Figure 12-25 Connecting a Multiline Terminal to a PC using a CT(U)-R( ) Unit (Example) shows how the CT(U)-R( ) Unit is connected to the ESI(8)-U( ) ETU and to the PC. The required AC-2R/AC-3R Unit is not shown.
  • Page 576: Figure 12-26 Attaching The Ct(U)-R( ) Unit To The Multiline Terminal

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Plug the tabs marked A and B into adapter slots, then snap the tab on the other end of the adapter into the receptacle marked C. Refer to Figure 12-26 Attaching the CT(U)-R( ) Unit to the Multiline Terminal on page 12-20.
  • Page 577: Connecting The Ct(U)-R( ) Unit To The Pc

    UNIVERGE SV8100/SV8300 Issue No. 1.5 3.5.2 Connecting the CT(U)-R( ) Unit to the PC Connect USB cable from the PC to the CT(U)-R( ) Unit as shown in Figure 12-27 Connecting the USB Cable to the CT(U)-R( ) Unit. Figure 12-27 Connecting the USB Cable to the CT(U)-R( ) Unit 3.5.3...
  • Page 578: Installing An Hf-R( ) Unit On Any Dtr/Dth Multiline Terminal (Except Dtr-2Dt-1( ))

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.1.1 Installing an HF-R( ) Unit on any DTR/DTH Multiline Terminal (except DTR-2DT-1( )) With terminal upside down, facing from the bottom of the open cover, install this unit in terminal adapter Slot 1. Figure 12-28 Attaching the HF-R( ) Unit to the Multiline Terminal Plug the tabs marked A and B into adapter slots, then snap the tab on the other end of the adapter into the receptacle marked C.
  • Page 579: Installing The External Microphone

    Installing the External Microphone An external microphone can be installed on the HFU-U Unit. These instructions apply to the external microphone obtained from NEC. The microphone has a locking mute button and a red LED indicator that is off when the microphone is in mute.
  • Page 580: Connecting The Interface Unit

    Issue No. 1.5 UNIVERGE SV8100/SV8300 4.2.1 Connecting the Interface Unit Set DSW1 to the pattern for the applicable multiline terminal as shown in Table 12-4 DSW1 Switch Positions on the next page. Place the ADM and multiline terminal upside down and remove the Base Units.
  • Page 581: Wall Mounting Adm And Multiline Terminal

    UNIVERGE SV8100/SV8300 Issue No. 1.5 The connector plate cannot be used with InMail terminals. Figure 12-32 Installing the Connector Plate Replace the base units as shown in Figure 12-31 ADM and Multiline Terminal with Base Covers Removed. 4.2.2 Wall Mounting ADM and Multiline Terminal Remove both base units.
  • Page 582: Figure 12-33 Installing Base Units On The Wall

    Issue No. 1.5 UNIVERGE SV8100/SV8300 Install the ADM and multiline terminal as shown on Figure 12-31 ADM and Multiline Terminal with Base Covers Removed on page 12-24. Figure 12-33 Installing Base Units on the Wall term 12 - 26 Installing D...
  • Page 583: Nec Push-To-Mute (Ptm) Or Push-To-Talk (Ptt) Handset

    Using the PTM or PTT handset on an NEC digital terminal prevents eavesdropping and eliminates the worry that privileged information could be transmitted without user authority. These handsets are also an ideal solution to filter unwanted audio transmissions from environments with ambient background noise.
  • Page 584 Issue No. 1.5 UNIVERGE SV8100/SV8300 term 12 - 28 Installing D Series i Optional Equipment...
  • Page 586 YSTEM ARDWARE ANUAL NEC Australia Pty Ltd Issue No. 1.5 NWA-033622-001 To view the latest issue of this document go to NEC Knowledgebase at http://www.kbase.cns.nec.com.au and search for NEC-10536.

This manual is also suitable for:

Univerge sv8300

Table of Contents