hit counter script
Download Print this page
ABB EDS500 Series Operating	 Instruction

ABB EDS500 Series Operating Instruction

Managed ethernet switch
Hide thumbs Also See for EDS500 Series:

Advertisement

Quick Links

Operating instruction
Operating instruction
Managed Ethernet switch 500NMD44
Managed Ethernet switch 500NMD44
EDS500 series - Ethernet & DSL switches
EDS500 series - Ethernet & DSL switches
Application, characteristics and technical data have to
be taken from the hardware data sheet:
500NMD44 Data sheet 1KGT150996
Operation
The compact modem 500NMD44 has two optical
interface as SFP plug-in and four Ethernet interfaces.
There are two serial interfaces for configuration or
process interface (e.g. to connect telecontrol units). A
configurable alarm relais and an extension interface
(e.g. to use the configuration stick) complete the
device.
Figure 1: 500NMD44 Blockschaltbild
Connections
Ethernet interfaces (Port1 - Port4)
Every Ethernet interface detects automatically
whether the connected counterpart works as
transmission or network termination device. This way
both normal and crossover cables can be used (MDI/
MDI-X).
RS-232/
RS-485
Console0
Tunnel
CFG
Tunnel
Configuration
and Monitoring
Intelligent Switch
(Layer 2 or 3)
1
2
3
4
WAN
WAN
RS-232
Console1
CFG
5
6
local LAN
The Ethernet interface can operate at transmission
rates of 10 or 100 Mbps, depending on the connected
devices in half duplex or full duplex mode. The
operation mode is detected and set automatically
by the EDS500 devices. A manual configuration is
possible.
Pin allocation Ethernet interface (RJ-45)
Pin
assigned as data
transmission
device (MDI)
1
Tx+
2
Tx-
3
Rx+
8
1
4
n.c.
5
n.c.
6
Rx-
7
n.c.
8
n.c.
SFP Interfaces (Fo1 - Fo2)
All SFP interfaces are designed according to Small
Form-Factor Pluggable (INF-8074i).
W A R N I N G
Only transceivers up to laser class 1 according to
EN 60825-1 are allowed to be used for the SFP
interfaces.
A D V I C E
Any warranty claims can only extend to SFPs
delivered by ABB.
Serial interfaces (Con0 - Con1)
The serial interfaces of the device are signal
compatible to RS-232. The connector is an RJ-12
modular jack. The factory presets are speed 57600
Baud, no parity, 1 stop bit, no flow control. Via the
serial interfaces the management console can be
accessed .
assigned as
network termi-
nation device
(MDI-X)
Rx+
Rx-
Tx+
n.c.
n.c.
Tx-
n.c.
n.c.

Advertisement

loading

Summary of Contents for ABB EDS500 Series

  • Page 1 Operating instruction Operating instruction Managed Ethernet switch 500NMD44 Managed Ethernet switch 500NMD44 EDS500 series - Ethernet & DSL switches EDS500 series - Ethernet & DSL switches Application, characteristics and technical data have to The Ethernet interface can operate at transmission...
  • Page 2 Pin allocation serial interface RS-232 (RJ-12) Pin allocation power supply PoE (X3) RS-232 RS-232 PC SUB-D9 Signal Pin Signal Direction Pin Signal Direction R0001: 51-57 V DC DCD Output DCD Input R0002: 24-60 V DC Output Input Shield connected to functional earth Input Output (internally wired to pin 4)
  • Page 3 Signaling Device configuration The 500NMD44 can be configured locally as well as Description Function from remote. In the following some methods are Power Voltage Device is without introduced, for a complete description please see Supply power supply EDS500 Manual - Part 2: Functions (1KGT151021). green Power supply switched on...
  • Page 4 There are two authentication levels on the A D V I C E • command line: Login authentication and Enable authentication. Login authentication can be When using a managed SFP unit, parameters of the described as a read only mode and is accessible optical interface like signal quality or temperature directly after establishing a serial connection can be displayed and monitored.
  • Page 5 W A R N I N G < s e t s y s t e m s n t p s e r v e r { I P a d d r e s s } > An easy to access manual interrupter has to be <...
  • Page 6 Figure 2: 500NMD44 Front plate Figure 3: 500NMD44 R0001 Label Figure 4: 500NMD44 R0002 Label...
  • Page 7 ABB Power or in parts – is forbidden without prior written Grids Germany AG does not accept any consent of ABB Power Grids Germany AG. responsibility whatsoever for potential Copyright© 2020 ABB Power Grids Germany AG errors or possible lack of information in All rights reserved solutions.abb/eds500...

This manual is also suitable for:

500nmd44