Cisco NCS 540 Installation Manual page 31

Small density passive cooled routers
Hide thumbs Also See for NCS 540:
Table of Contents

Advertisement

Install the Cisco N540-6Z14S-SYS-D Routers
2. Align the mounting holes in the bracket (and optional cable guide) with the mounting holes in the equipment
rack.
The following figure shows how to install the router in a 19-inch EIA rack.
Figure 7: Install the Chassis in a 19-inch EIA Rack
Figure 8: Install the Chassis in a 23-inch EIA Rack
3. Install the eight 12-24 x 3/4-inch or 10-32 x 3/4-inch zinc-plated steel screws through the holes in the
bracket and into the threaded holes in the equipment rack posts.
4. Use a tape measure and level to verify that the chassis is installed straight and level.
Cisco Network Convergence System 540 Passive Cooled Small Density Routers Hardware Installation Guide
Install the Router Chassis in the Rack
25