hit counter script
Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual

Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1511:

Advertisement

Quick Links

Edition
10/2021
Installation Manual
SIMATIC NET
Rugged Multi Service Platforms
RUGGEDCOM RX1511
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RX1511

  • Page 1 Edition 10/2021 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1511 https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1511 Modules Technical Specifications Installation Manual Certification 10/2021 C79000-G8976-1056-21...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vii Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Installing/Removing Power Modules ..............28 Technical Specifications ...................... 31 Power Supply Specifications ................31 Failsafe Relay Specifications ................31 Operating Environment ..................32 Mechanical Specifications ..................32 Dimension Drawings ................... 32 Certification ......................... 35 Approvals ......................35 6.1.1 TÜV SÜD ......................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RX1511 is available online at https:// support.industry.siemens.com.
  • Page 7: Warranty

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Customer Support

    Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RX1511 is a cost-efficient, rugged Layer 3 switch and router. The RUGGEDCOM RX1511’s modular and field replaceable platform can be equipped with WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems. The appliance’s compact form factor makes it ideal for pole mount applications or installation in restricted spaces.
  • Page 11 Introduction 1.2 Description Utility USB Port RS232 Serial Console Port (RJ45) Lamp Test/Alarm Cut-Off (LT/ACO) Button Compact Flash Card Port Alarm Indicator LED Port Status LEDs Management Port Figure 1.1 RUGGEDCOM RX1511 Management Port This 10/100Base-T Ethernet port is used for system management that is out-of-band from the switch fabric.
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials • Red = Alarm Compact Flash Card Port Houses the CompactFlash (CF) card that contains active and backup installations of RUGGEDCOM RUGGEDCOM RX1511, along with the configuration database and other system data. For more information, refer to "Accessing the CompactFlash Card (Page 21)".
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment. Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 15: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: Mounting The Device

    2.3 Mounting the Device Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel.
  • Page 17: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.1 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 18: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and mark the mounting holes on the panel. Screw Panel/DIN Rail Adapter Figure 2.2 Panel Mounting Prepare the mounting holes Align the device with the mounting holes and secure it to the panel.
  • Page 19: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1511 supports a single high AC, high DC or low DC power module. Power modules can be equipped with either a screw or European-style (Euroblock) terminal block.
  • Page 20: Connecting High Ac/Dc Power

    Installing the Device 2.5.1 Connecting High AC/DC Power 2.5.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: DANGER Electrocution hazard – risk of death, serious personal injury and/or damage to the device Make sure the supplied cover is always installed over high voltage screw terminal blocks.
  • Page 21 Installing the Device 2.5.1 Connecting High AC/DC Power Connect the power supply terminal block to the device. European-style (Euroblock) Terminal Block Positive/Live (+/L) Terminal Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.4 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 22 Installing the Device 2.5.1 Connecting High AC/DC Power Note For secure, reliable connections under severe shock or vibration, use M3.5 ring lugs with a maximum outer diameter of 7 mm (0.28 in). Make sure no bare metal is exposed beyond the safety cover. Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
  • Page 23: 2.5.2 Connecting Low Dc Power

    Installing the Device 2.5.2 Connecting Low DC Power Using a #10 ring lug and #10-32 screw, secure the ground terminal on the power source to the ground connection on the device. Make sure the lug is tightened to 1.1 N·m (9.5 lbf·in). #10 Ring Lug #10-32 Screw Connection from External Power Source...
  • Page 24 Installing the Device 2.5.2 Connecting Low DC Power Connect the power supply terminal block to the device. European-style (Euroblock) Terminal Block Positive (+) Terminal Negative (-) Terminal Ground Terminal Figure 2.8 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 25 Installing the Device 2.5.2 Connecting Low DC Power Ground Terminal Figure 2.9 DC Terminal Block Wiring – Screw Terminal Block for 12P, 24P and 48P Power Supplies European-style (Euroblock) Terminal Block Positive (+) Terminal Negative (-) Terminal Ground Terminal Figure 2.10 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 26 Installing the Device 2.5.2 Connecting Low DC Power Negative (-) Terminal Ground Terminal Figure 2.11 DC Terminal Block Wiring – Screw Terminal Block for -12P, -24P and -48P Power Supplies Note For secure, reliable connections under severe shock or vibration, use M3.5 ring lugs with a maximum outer diameter of 7 mm (0.28 in).
  • Page 27 Installing the Device 2.5.2 Connecting Low DC Power Using a #10 ring lug and #10-32 screw, secure the ground terminal on the power source to the ground connection on the device. Make sure the lug is tightened to 2.4 N·m (9.5 lbf·in). #10 Ring Lug #10-32 Screw Connection from External Power Source...
  • Page 28: Device Management

    It may cause damage to the contact pins of the RJ45 ports. For a permanent solution, use Siemens 6XV1870-3Qxxx certified cables (manufactured December 2019 or after) or equivalent. Siemens recommends using Siemens certified cables and connectors for Siemens RUGGEDCOM products.
  • Page 29 Device Management 3.1 Connecting to the Device Serial Console and Management Ports Connect a workstation directly to the serial console or management ports to access the boot-time control and RUGGEDCOM RX1511 interfaces. The serial console port provides access to RUGGEDCOM RX1511's console interface, while the management port provides access to RUGGEDCOM RX1511's console and Web interfaces.
  • Page 30: Configuring The Device

    The following will void the warranty and potentially result in configuration data corruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
  • Page 31 Device Management 3.3 Accessing the CompactFlash Card Inserting the CF card To insert the CF card into the device, do the following: NOTICE The device should only be powered on when the CF card is present. Make sure the device is powered down. Remove the CF card access panel.
  • Page 32 Device Management 3.3 Accessing the CompactFlash Card Remove the CF card access panel. Ejector Button CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis.
  • Page 33 Device Management 3.3 Accessing the CompactFlash Card RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 34: Modules

    Modules The RUGGEDCOM RX1511 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 35: Available Modules

    A variety of modules are available for use with the RUGGEDCOM RX1511. For more information, refer to the "RUGGEDCOM Modules Catalog [https:// support.industry.siemens.com/cs/us/en/view/109747072]" for the RUGGEDCOM RX1511. Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM RX1511.
  • Page 36 Modules 4.3 Installing/Removing Line Modules Pull the module from the chassis to disconnect it. Module Chassis Screw Figure 4.2 Removing a Module Install a new module or a blank module (to prevent the ingress of dust and dirt). [Optional] If necessary, install the device in the rack. Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack.
  • Page 37: Installing/Removing Power Modules

    Modules 4.4 Installing/Removing Power Modules Insert the new module into the slot. Module Chassis Screw Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Installing/Removing Power Modules The RUGGEDCOM RX1511 supports a single power module. Power Module Figure 4.4 Power Module...
  • Page 38 Modules 4.4 Installing/Removing Power Modules NOTICE Contamination hazard – risk of equipment damage Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots are not left empty. Removing a Power Module To remove a power module, do the following: DANGER Electrocution hazard –...
  • Page 39 Modules 4.4 Installing/Removing Power Modules Installing a Power Module To install a power module, do the following: If equipped, remove the existing module. If applicable, connect the supplied terminal block to the module or connect the terminal block from the previous module. Confirm or connect the wiring from the power supply to the module.
  • Page 40: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Input Range Maximum Power Internal Power Insulation...
  • Page 41: Operating Environment

    Technical Specifications 5.3 Operating Environment Operating Environment The RUGGEDCOM RX1511 is rated to operate under the following environmental conditions. Note Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1511. Make sure the selected modules are rated for the expected environmental conditions before deployment.
  • Page 42 Technical Specifications 5.5 Dimension Drawings 151.1 Figure 5.1 Overall Dimensions RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 43 Technical Specifications 5.5 Dimension Drawings 199.9 152.4 189.9 78.2 Figure 5.2 Panel and Din Rail Mount Dimensions 162.5 151.4 19.7 Figure 5.3 Line Module Dimensions 162.5 151.8 40.6 Figure 5.4 Power Module Dimensions RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 44: Certification

    UL 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU...
  • Page 45: 6.1.3 Fcc

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 46: Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 47: 6.1.7 Iso

    Quality management systems – Requirements 6.1.8 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 48: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests EMC and Environmental Type Tests The RUGGEDCOM RX1511 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure Contact ±...
  • Page 49 5 kV (Failsafe Relay output) DC Power Ports 5 kV AC Power Ports Siemens-specified severity levels. EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1511 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 50 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60255-21-3 Seismic Method A Level 2 RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 51 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RX1511 Installation Manual, 10/2021, C79000-G8976-1056-21...
  • Page 52 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2021 Siemens Canada Ltd. Subject to change...

Table of Contents