SAMSUNG GX -series digital SLR camera. For further information on the use of this function, refer to p11. Schneider D-XENON/SAMSUNG lens can be used only with SAMSUNG GX -series SLR cameras. It is not compatible with film SLR cameras.
FOR SAFE USE OF YOUR LENS Although we have carefully designed these lenses for safe operation, please pay special attention to items marked with the following symbols when using this product. WARNING CAUTION WARNING • Never look at the sun through the lens or camera. Serious damage to the retina or total loss of eyesight may occur.
PRECAUTIONS AND LENS MAINTENANCE 1. Storage and mildew prevention • Take the lens out of the protective case or camera bag, and store it in a dry, well-ventilated place. • Avoid storing the lens in a poorly ventilated location such as a closet, wardrobe, drawer, vehicle, or where insect repellent or medicine is kept.
● FOREWORD ● FOR SAFE USE OF YOUR LENS ...1 ● PRECAUTIONS AND LENS MAINTENANCE ...2 ● LENS ...4 ■ About the lens mount ...5 ● MOUNTING AND REMOVING THE LENS ...6 ● LENS CAP...7 ● FOCUSING...8 ■ Changing the Focus Mode ...8 ■...
Focus Ring Zoom ring Mounting index Note: The Schneider D-XENON 18-55/50-200/Samsung 16-45 lens does not have an aperture ring. 《4》 LENS Lens hood attaching index Focus distance index Focus distance Zoom distance Zoom distance index...
About the lens mount The Schneider D-XENON/SAMSUNG lens is an interchangeable lens specifically designed for the SAMSUNG GX -series digital SLR camera. The K 2-mount of the Schneider D-XENON/SAMSUNG lens is similar to conventional SLR lenses, but the lens cannot be used on 35 mm SLR cameras.
MOUNTING AND REMOVING THE LENS To mount the lens on the camera body Attach the lens while aligning the red dots on the lens and body, then turn the lens clockwise until it clicks in place. Memo: • Do not hold down the lens unlock button while mounting the lens, otherwise the lens will not be properly mounted.
Changing the Focus Mode Use the camera’s focus mode switch to change between the auto focus (SAF, CAF) mode and manual focus mode. For details, refer to your camera’s manual. Using Autofocus Set the camera’s focus mode to autofocus(AF/SAF/CAF). Press the shutter button halfway to autofocus.
Page 11
During autofocusing, the focusing ring of following lenses will rotate. • To prevent malfunction, do not touch the focusing ring during autofocusing. - Schneider D-XENON 18-55mm F/3.5-5.6 AL - Schneider D-XENON 50-200mm F/4-5.6 ED - SAMSUNG 16-45mm F/4 ED AL 《9》...
Page 12
Using Manual Focus Set to MF with the camera’s focus mode, and turn the focusing ring to focus manually. 《10》...
Using the Quick-Shift Focus System (GX -series cameras only) If you use the lens with an GX -series camera and the focus mode is set to autofocus, you can focus manually after autofocus is achieved. Just turn the focusing ring to manually touch-up the focus.
Page 14
• To prevent malfunction, do not touch the focusing ring during autofocusing. - Schneider D-XENON 18-55mm F/3.5-5.6 AL - Schneider D-XENON 50-200mm F/4-5.6 ED - SAMSUNG 16-45mm F/4 ED AL • When using the Quick-Shift Focus System, keep pressing the shutter button after you achieve focus before taking a picture.
When taking a picture in this range, we recommend that you use a smaller aperture with stopping down from wide open.(When using the SAMSUNG 16-45mm lens, the aperture value is fixed as F4.) 《13》...
The zoom lens has a focusing ring at the front and a zoom ring behind it. Turn the zoom ring to set the desired angle of view (lens focal length). Memo: • The focusing point may shift slightly by changing the focal length. First adjust the zoom and then adjust focus.
ATTACHING THE LENS HOOD In order to avoid the deterioration in image quality from internal reflection, use of the lens hood is recommended. When attaching the lens hood, align the index on the lens hood with the attaching index on the lens, and push both parts straight toward each other.
About the PL filter window If a circular polarizing filter is attached to the Schneider D-XENON/SAMSUNG lens, you can easily turn the filter via the PL filter window on the bayonet-type hood. Lens hood with [PL filter window] - Schneider D-XENON 18-55mm F/3.5-5.6 AL - Schneider D-XENON 50-200mm F/4-5.6 ED...
Page 19
Attach the PL filter window cap. Memo: • When shooting, be sure the PL filter window cap is in place to make that the lens hood is being used to maximum effect. 《17》...
Make sure the filter size matches the lens and then attach the filter onto the lens. Memo: • The compatible filter sizes for all the lenses are listed on pages 20. Precaution on filters • Since the filter becomes a part of the optics when attached on the lens, handle it in the same way you handle the lens with care to dust, dirt and scratches.
• The built-in flash may be blocked by the lens hood. Always make sure to remove the lens hood before using the built-in flash. Compatibility of D-XENON Lenses with the Built-in Flash Lens Schneider D-XENON 18-55mm F/3.5-5.6 AL Schneider D-XENON 50-200mm F/4-5.6 ED SAMSUNG 16-45mm F/4 ED AL Notes Compatibility 《19》...
MAIN SPECIFICATIONS Lens Schneider D-XENON18-55mm 18-55mm (equivalent to Focal Length 27.5~84mm in 35mm format) Usable camera Samsung DSLR cameras Elements in groups 9 groups, 12 elements Angle of View 29˚ ~ 76˚ Aperture F3.5 ~ F5.6 Mount Type PENTAX K Minimum Focus 0.25m...
For customers in USA STATEMENT OF FCC COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.