Page 1
HEAT & COOL ION FAN OPERATION MANUAL HD Plasmacluster 冷暖離子抗菌機 使用説明書 IG-HH1A *The number in this technical label indicates the Read this manual carefully and keep approximate amount of ions that the Plasmacluster Ion Generating Unit emits into every 1 cm of air, it properly.
*Replacement is required approximately every 2 years (17,500 hours) when operated 24 hours a day. IG-HH1A will stop operating after about 2 years and 2 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced. this SHARP High Density Plasmacluster Heat & Cool Ion Thank you for purchasing Fan.
FREQUENTLY Please also refer to ASKED QUESTIONS "TROUBLESHOOTING" on pages E-20 and E-21. Are there ON/OFF Timer functions? You can set "OFF Timer" by pressing the TIMER button during operation. (See page E-12.) You can set "ON Timer" by pressing the TIMER button while not in operation. (See page E-12.) *The ON Timer and OFF Timer cannot be set at the same time.
IMPORTANT SAFETY INSTRUCTIONS Please read instructions carefully before using the product, in order to avoid personal injury and property damage. ■ The risks caused by wrong operation are classified as follows. Risks that may lead to death or Risks that may result in minor injury or WARNING CAUTION serious injury.
In case spill is done by accident, please stop (It may cause a burn.) using the unit immediately, and contact the store you purchased the product from or Sharp service center for inspection or repair. (Overheating or electric shock may result.) ●...
BEFORE OPERATION Installation guidelines Place the unit on a proper place. ● Wall or furniture may be stained and/or deformed when the unit is used with the air inlet near them. Leave an * Do not let open space on the left or right side, and keep at least 5 5 cm or more the curtain 60 cm or...
PARTS NAME Main unit FRONT BACK Handle Operation panel Remote controller housing part Remote controller receiver Maintenance (See page E-17) Display panel Replacement (See page E-18) Unit holder Air outlet Unit Louver Unit cover Do not touch the air (The cleaning brush is attached outlet and louver to the inside of unit cover) during hot fan...
You cannot start the hot air operation/foot warming operation and timers Remote controller operation with the remote controller. This is to prevent the hot fan operation from starting due to malfunction. Transmitter window When housing the remote controller, COOL FAN button POWER OFF button (blue mark) insert it to the housing part at...
OPERATION CAUTION Do not touch the air outlet and louver during the hot fan operation. Turn on the main switch at the back of the main unit before starting [Otherwise, it may cause burns] the operation. Start/Stop hot fan operation ●...
Page 11
● Plasmacluster ions will be generated in all operation modes. ● When operation is stopped by pressing the POWER OFF button on the main unit or the remote controller, the last operation mode will be memorized. (Memory Function) ● The settings of the timers, Plasmacluster Ions Clean mode and Clothes Deodorizing mode will not be memorized.
● When there is no horizontal swing or louver movement for 20 seconds after starting the operation of horizontal or vertical swing, please immediately remove the plug from the power outlet, and contact the store you purchased or Sharp service center. Horizontal swing/Angle setting "Horizontal swing ON"...
Page 13
ON/OFF Timer wYou cannot set ON/OFF Timer at the same time. OFF Timer (The operation will stop automatically when the set time is reached.) (While in operation) ("OFF" indicator flashes) Main unit ● At the end of the setting, the TIMER indicator light (white) and the OFF TIMER indicator light (white) will turn on.
Page 14
USEFUL FUNCTIONS (continued) Patrolling function This function allows you to learn about the room conditions. This product cannot reduce the room temperature, and adjust the humidity. If the patrolling function is set, the sensor detects a state requiring attention to room temperature and humidity during operation and tells it with Patrolling indicator light and sound.
Page 15
Sometimes, it may not get the accurate temperature and humidity because of the installation location (near a cooler, dehumidifier, or humidifier) and operation environment of the product. Operation panel Patrolling function while not in operation ● You can set the patrolling function by pressing the PATROLLING button even when no operation is taking place.
Page 16
USEFUL FUNCTIONS (continued) Ion mode operation Plasmacluster ions are generated in all operation modes. *Plasmacluster Ions mode and Clothes Deodorizing mode will be automatically switched to cool fan operation. (While in operation) Select the appropriate Ion mode. (Three modes are available as follows.) Remote controller Pip Pip (Off)
CAUTION CARE AND Stop the operation, let the main unit to cool completely, then remove the plug from the power outlet before performing maintenance. MAINTENANCE (Or you will get burned, electric shock or wounded.) Main unit About once in every month Wipe the surface with a soft cloth.
CAUTION CARE AND To replace the Plasmacluster Ion Generating Unit, first stop the operation, let the main unit to cool completely, MAINTENANCE then remove the plug from the power outlet. (Or you will get burned, electric shock or wounded.) (continued) Plasmacluster Ion Generating Unit About once in every 6 months (electrode section)
REPLACEMENT OF PLASMACLUSTER ION GENERATIONG UNIT When the total operation time of the generator exceeds 17,500 hours (approximately 2 years when the product operates 24 hours a day), the replacement indicator of the generating unit (Plasmacluster Ion Generating Unit) will flash to indicate that the unit needs replacement.
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT Power off and unplug the unit. wStart maintenance after the unit is cooled down. 2 Pull out the unit holder 1 Remove the cover 3 Detach the unit from the holder by pushing following the direction of pressing the hook its front and back at the same time following...
TROUBLESHOOTING Please check "FREQUENTLY ASKED QUESTIONS" (page E-2). Reference PROBLEMS WHAT TO DO page Operation fails ● Is the plug securely inserted, and is the fuse or circuit breaker damaged? • The indicators on Display/ — Operation panel are turned off. •...
Page 22
E-11 seconds after starting the operation of horizontal or vertical swing, please immediately remove the plug from the power outlet, and contact the store you purchased the product from or Sharp service center. ● Plasmacluster ions are not released. E-17 Clean the electrode section with the attached cleaning brush.