Cisco N540-FH-CSR-SYS Install Manual page 4

Hide thumbs Also See for N540-FH-CSR-SYS:
Table of Contents

Advertisement

Install the Device
Rack Mount
1. Attach the rack-mount brackets and the cable guides to the router as follows:
a. The router has port-side intake modules, position the router so that its ports are facing the cold aisle.
b. Position the bracket ears facing front or middle rack-mount, on the side of the chassis so that the holes
are aligned.
c. Use four M4 screws to attach the brackets to the chassis.
d. Repeat Steps 1b and 1c with the other rack-mount bracket on the other side of the router.
Figure 4: Installing Rack-Mount Brackets
Install the Device
4