Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instruction
protection
manual
1. SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using
this equipment.
WARNING! Disconnect from air supply before changing engraving tips, or servicing ,or performing any maintenance.
Maintain the engraver in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Use in a suitable work area. Keep area free from unrelated materials and ensure that there is adequate lighting.
9
Before each use check condition of engraving tip. Sharpen if necessary. If worn or damaged replace immediately.
9
Ensure there are no flammable or combustible materials near the work area.
9
WARNING! Always wear approved eye (or face) and hand protection when operating the engraver.
Use face, dust, or respiratory protection in accordance with COSHH regulations.
9
Remove ill fitting clothing. Remove ties, watches, rings, other loose jewellery and contain and/or tie back long hair.
9
Wear appropriate protective clothing and keep hands and body clear of working parts.
9
Maintain correct balance and footing. Do not over reach, ensure the floor is not slippery, wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
Check moving parts alignment on a regular basis.
9
Ensure workpiece is secure before operating the engraver.
9
Avoid unintentional starting.
9
WARNING! Ensure correct air pressure is maintained and not exceeded. Max air pressure = 60PSI
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections
9
are secure.
Prolonged exposure to vibration from this equipment poses a health risk. It is the owner's responsibility to correctly assess the
9
potential hazard and issue guidelines for safe periods of use and offer suitable protective equipment.
DO NOT use the engraver for a task it is not designed to perform.
8
DO NOT operate the engraver if any parts are damaged or missing as this may cause failure and/or personal injury.
8
DO NOT carry the engraver by the hose, or yank the hose from the air supply.
8
DO NOT force, or apply heavy pressure to the engraver; let the tool do the work.
8
DO NOT place air line attachments close to your face and do not point at other people or animals.
8
DO NOT operate engraver when you are tired, under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT use engraver where there are flammable liquids, solids or gases such as paint solvents and including waste wiping or
8
cleaning rags etc.
DO NOT direct air from the air line at yourself or others. When not in use, disconnect from the air supply and store in a safe, dry,
8
childproof location.
2. INTRODUCTION
Composite bodied high quality tool with Tungsten Carbide tip for engraving metals and plastics. Suitable for security marking loan products,
applying service date information to tools and for marking components prior to storage. Supplied with 1.5m of small-bore hosing and
1/4"BSP adaptor.
3. SPECIFICATION
Model no: ...................................................................... SA96
Air inlet size: .............................................................1/4"BSP
Consumable parts: .............................SA96/03 - Tungsten tip
Free speed: ............................................................. 3000spm
Noise power/pressure: ......................................... 84/73dB(A)
Operating pressure: ...................................................... 60psi
Vibration/Uncertainty: ....................................... 3.89/0.88m/s²
© Jack Sealey Limited
AIR ENGRAVER
MODEL NO:
Wear ear
Wear protective
Wear a mask
protection
gloves
Original Language Version
SA96
SA96 Issue:3 (H,F) 26/07/21

Advertisement

loading

Summary of Contents for Sealey SA96

  • Page 1 SA96 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 ‰ 6.7. LUBRICATION 6.7.1. The air system does not have an oiler, lubricate the air tool daily with a few drops of Sealey air tool oil dripped into the air inlet. 6.8. Clean the tool after use. 6.9. Loss of power or erratic action may be due to the following: - Excessive drain on the air line.
  • Page 3 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...