hit counter script
Download Print this page
Sealey AK4562 Quick Start Manual
Sealey AK4562 Quick Start Manual

Sealey AK4562 Quick Start Manual

Oil dispensing system air operated

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instruction
gloves
manual
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.
9
9
Maintain the pump station in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.
9
Use only to pump lubricants up to SAE 150 viscosity.
9
Ensure safety eye protection, oil resistant gloves and protective clothing are worn when using this product.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
9
9
Keep children and unauthorised persons away from the working area.
After use, drain any fluids from the equipment before storage.
9
9
Dispose of waste liquids in accordance with local authority regulations.
9
Disconnect air pressure from equipment when not in use.
8
DO NOT exceed the maximum air pressure of 115psi.
DO NOT point the nozzle at people or animals.
8
DO NOT use the equipment near open flames.
8
8
DO NOT smoke whilst using this equipment.
DO NOT use to extract corrosive fluids.
8
8
DO NOT dismantle, tamper with or adapt the pump for any purpose other than for which it is designed.
8
DO NOT use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
8
DO NOT leave the trolley on a slope, or traverse slopes, which may cause the unit to topple.
9
The unit must be stored on a level surface.
9
Keep the pump clean and store in a safe dry, childproof location.
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to
authority regulations.
2.
INTRODUCTION
i
Mobile oil dispensing unit with air operated 3:1 double acting pump for barrels or
tanks with 2"BSP fittings. Pump is supplied with air management system
connected to a 940mm rigid suction probe with non-return valve. Features
10mtr retractable hose reel and digital oil meter Model No. AK4565D. Suitable
for use with engine, hydraulic, synthetic, gear, and transmission oils up to SAE150.
3.
SPECIFICATION
i
Model No: ...............................................................AK4562D
Maximum Air Pressure: ................................................115psi
Maximum Flow Rate: ............................................... 12ltr/min
Maximum Output Pressure: ........................................ 350psi
Maximum Trolley Capacity: .......................................... 220kg
Maximum Viscosity: .................................................. SAE150
Nett Weight: ................................................................72.6Kg
Outlet Size: ...............................................................1/2"BSP
Pump Ratio: ...................................................................... 3:1
Recommended Air Pressure: ........................................ 70psi
Digital Hose End Meter
Model ......................................................................AK4565D
Accuracy: ..................................................................+/- 0.5%
Inlet: ..........................................................................1/2"BSP
Battery: ......................................... Lithium CR2 3V 1400mAH
© Jack Sealey Limited
OIL DISPENSING SYSTEM AIR OPERATED
MODEL NO:
Wear eye
Wear protective
protection
clothing
Original Language Version
AK4562
Wear safety
footwear
AK4562D Issue 3 (H, 5, F) 24/09/18

Advertisement

loading

Summary of Contents for Sealey AK4562

  • Page 1 AK4562 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Insert the pump assembly into the support brackets on the trolley and hang the meter onto the accessory support bracket. 4.3. PRE-OPERATION 4.3.1. Lift up the knob (fig.2A) on the air regulator and ensure that the knob is wound fully anti-clockwise. 4.3.2. Remove the filler plug (fig.2B) from the lubricator and fill the lubricator with a quality air tool oil (Sealey ATO1000S), refit the filler plug. 4.3.3. The lubricator feed is set when the unit is running, adjust the feed knob (fig.2C) the drip rate can be seen through the sight glass of the dome. The rate of oil feed will automatically increase or decrease inline with the air flow. © Jack Sealey Limited Original Language Version AK4562D Issue 3 (H, 5, F) 24/09/18...
  • Page 3 Press and hold MOVE key until all digits illuminate and display shows ‘Cal’ (fig.12). 5.4.4. Press RESET to set digit values (from right to left) (fig.13). 5.4.5. Once value is correct hold down MOVE key until Cal mode quits. fig.10 fig.11 © Jack Sealey Limited Original Language Version AK4562D Issue 3 (H, 5, F) 24/09/18...
  • Page 4 BATTERY REMOVAL SEE SECTION 6 Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.