Setting up the ME4 Series expansion enclosure Consider the following best practices when setting up an ME4 Series expansion enclosure. ● Before connecting any cables between the storage system and the host server or expansion enclosure, physically label each port and connector. ●...
Other information you may need To install the storage system, you may need the following additional information: NOTE: See the Enterprise Products Safety, Environmental, and Regulatory Information that shipped with your storage system. Warranty information is included as a separate document. ●...
Installation safety precautions Always follow these safety precautions to avoid injury and damage to storage system equipment. If equipment described in this guide is used in a manner not specified by the documentation, the protection provided by the equipment could be impaired. For your safety and protection, observe the rules described in the following sections. Follow these safety precautions: ●...
Page 6
The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): NOM information Importer Dell México, S.A. de C.V Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa Fe Delegación Álvaro Obregón, Ciudad de México C.P.
Technical specifications AC power supply specifications Maximum output power 2.2 Kw Maximum input power 2433 W Maximum input current 13.52 A at 180 VAC Maximum inrush current 27 A at 2.89s, 39 A at 1s Nominal input voltage operating range 200-240 VAC Nominal input frequency 50/60 Hz...