Panasonic WH-ADC1216G6E5 Service Manual

Panasonic WH-ADC1216G6E5 Service Manual

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-ADC1216G6E5:

Advertisement

Quick Links

This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
Air-to-Water Hydromodule + Tank
Indoor Unit
WH-ADC1216G6E5
WARNING
PRECAUTION OF LOW TEMPERATURE
Order No: PAPAMY1412011CE
Outdoor Unit
WH-UX09FE5
WH-UX12FE5
WH-UD12FE5
WH-UD16FE5
Destination
Europe
© Panasonic Corporation 2014.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic WH-ADC1216G6E5

  • Page 1 PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit. © Panasonic Corporation 2014.
  • Page 2 1. Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating and main circuit for the model installed. ...
  • Page 3 WARNING 24. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over tightened, after a long period, the flare may break and cause refrigerant gas leakage. 25. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire.
  • Page 4: Input Power

    2. Specifications WH-ADC1216G6E5 WH-UX09FE5 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 7.00 Cooling Capacity BTU/h 23900 kcal/h 6020 3.17 Cooling EER kcal/hW 2.72 Condition A7W35 A2W35 (Ambient/Water) 9.00 9.00 Heating Capacity BTU/h 30700 30700 kcal/h...
  • Page 5: Table Of Contents

    Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 2.21 Heating: 1.86 Heating: 2.51 Maximum Input Power For Heatpump System 5.41 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 6 Item Unit Indoor Unit Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 6.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool Maximum Working Pressure Tank Circuit...
  • Page 7: Unit

    WH-ADC1216G6E5 WH-UX12FE5 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 10.00 Cooling Capacity BTU/h 34100 kcal/h 8600 2.81 Cooling EER kcal/hW 2.42 Condition A7W35 A2W35 (Ambient/Water) 12.00 12.00 Heating Capacity BTU/h 41000 41000 kcal/h 10320 10320 4.74...
  • Page 8: Cooling

    Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 3.56 Heating: 2.53 Heating: 3.49 Maximum Input Power For Heatpump System 6.27 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 9: Residual Current Circuit Breaker

    Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 6.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 10: Heating

    WH-ADC1216G6E5 WH-UD12FE5 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 10.00 Cooling Capacity BTU/h 34100 kcal/h 8600 2.81 Cooling EER kcal/hW 2.42 Condition A7W35 A2W35 (Ambient/Water) 12.00 11.40 Heating Capacity BTU/h 41000 38900 kcal/h 10320 9800 4.74...
  • Page 11: Heating: -20

    Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 3.56 Heating: 2.53 Heating: 3.31 Maximum Input Power For Heatpump System 5.30 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 12 Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 6.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 13 WH-ADC1216G6E5 WH-UD16FE5 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 12.20 Cooling Capacity BTU/h 41600 kcal/h 10490 2.56 Cooling EER kcal/hW 2.20 Condition A7W35 A2W35 (Ambient/Water) 16.00 13.00 Heating Capacity BTU/h 54600 44300 kcal/h 13760 11180 4.28...
  • Page 14 Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 4.76 Heating: 3.74 Heating: 3.96 Maximum Input Power For Heatpump System 5.74 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 15 Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 6.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 16 3. Features  Inverter Technology Energy saving  High Efficiency  Environment Protection Non-ozone depletion substances refrigerant (R410A)  Long Installation Piping Long piping up to 30 meter with height difference 20 meter Flexible 4-way piping for outdoor unit  Easy to use control panel Auto mode Holiday mode...
  • Page 17 4.1.4 Main Components cdef 1 Control Panel c Air Purge Valve Connector name Water Inlet 2 Water Pump d Pressure Relief Valve (From Space Heating/Cooling) 3 Control Board Cover e Flow Switch 4 PCB, Printed Circuit Board Water Pressure Gauge Water Outlet Single Phase RCCB/ELCB Top Front Plate...
  • Page 18 Outdoor Unit Air inlet (rear) Air inlet (side) Air outlet Air inlet (side) Air outlet...
  • Page 19 5. Dimensions Indoor Unit <Top View> <Side View> <Front View> <Bottom View> Unit: mm...
  • Page 20 Outdoor Unit <Top View> Space necessary for installation (140) 10 cm 10 cm 100 cm Anchor Bolt Pitch 355 x 260 <Side View> <Side View> <Front View> Unit: mm...
  • Page 21 6. Refrigeration and Water Cycle Diagram OUTDOOR UNIT INDOOR UNIT FLOOR HEATING AIR PURGE WATER OUTLET VALVE 3-WAY PRESSURE RELIEF VALVE VALVE WATER OUTLET TEMP. SENSOR EXPANSION FLOW SWITCH STRAINER VALVE STRAINER BACKUP HEATER ANODE BAR SANITARY HOT WATER OUTLET REFRIGERANT HEX WATER OUTLET TEMP.
  • Page 22 8. Wiring Connection Diagram Indoor Unit...
  • Page 23 Outdoor Unit 8.2.1 WH-UX09FE5 WH-UX12FE5 ELECTRONIC CONTROLLER (CAPACITOR) FG1 (GREEN) FG2 (GREEN) CN-BLK C N-ACL RELAY (BLACK) DCP-IN (BLACK) (WHITE) TERMINAL BOARD CAPACITOR NOISE FILTER CIRCUIT AC-BLK DCN-IN CIRCUIT (BLACK) CN-ACN (BLACK) (W HITE) AC-C (BLUE) DCN-OUT YELLOW CN-WHT (BLACK) (WHITE) ELECTRONIC CONTROLLER (SUB) REACTOR...
  • Page 24 8.2.2 WH-UD12FE5 WH-UD16FE5 ELECTRONIC CONTROLLER R EA C T O R (CAPACITOR) F G 1 (G R EE N ) F G 2 (G R EE N ) CN -B L K CN-ACL R E L A Y DC P -IN (B L A C K ) (BLACK) (W H IT E )
  • Page 25 The Capacity Rank can be set by Control Panel Press SET and SERVICE buttons simultaneously for 5 seconds. Press ▲/▼ button to select menu CAP RAN. Press SELECT button then press ▲/▼ button to change capacity rank and press SET button to confirm the outdoor capacity rank.
  • Page 26 18. Technical Data 18.1 Operation Characteristics 18.1.1 WH-ADC1216G6E5 WH-UX09FE5 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 14.000...
  • Page 27 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 28 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 12.000 11.000 10.000 9.000 8.000 7.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 29 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 30 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 Piping Length (m) 3.000 2.500 2.000...
  • Page 31 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 Piping Length (m) 2.500 2.400 2.300...
  • Page 32 18.1.2 WH-ADC1216G6E5 WH-UX12FE5 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 15.000 14.000 13.000 12.000 11.000...
  • Page 33 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 12.000 11.000 10.000 9.000 8.000 7.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 34 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 18.000 16.000 14.000 12.000 10.000 8.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 35 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 15.000 13.000 11.000 9.000 7.000 5.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 36 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 13.000 12.000 11.000 10.000 9.000 8.000 Piping Length (m) 4.000 3.500 3.000...
  • Page 37 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 11.000 10.000 9.000 8.000 7.000 6.000 Piping Length (m) 3.800 3.700 3.600...
  • Page 38 18.1.3 WH-ADC1216G6E5 WH-UD12FE5 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 13.000 12.000 11.000 10.000 9.000...
  • Page 39 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 12.500 11.500 10.500 9.500 8.500 7.500 (°C) Outdoor Temperature 5.500 4.500...
  • Page 40 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 16.000 15.000 14.000 13.000 12.000 11.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 41 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 12.000 11.000 10.000 9.000 8.000 7.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 42 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 12 .50 0 12 .00 0 11 .50 0 11 .00 0 10 .50 0 10 .00 0...
  • Page 43 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 11 .00 0 10 .00 0 9 .00 0 8 .00 0 7 .00 0 6 .00 0...
  • Page 44 18.1.4 WH-ADC1216G6E5 WH-UD16FE5 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 17.500 16.000 14.500 13.000 11.500...
  • Page 45 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 16.00 0 14.00 0 12.00 0 10.00 0 8.000 6.000 (°C)
  • Page 46 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 22.000 20.000 18.000 16.000 14.000 12.000 (°C) Outdoor Temperature 6.500 5.500...
  • Page 47 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 17.000 15.000 13.000 11.000 9.000 7.000 (°C) Outdoor Temperature 5.500 4.500...
  • Page 48 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 17.000 16.500 16.000 15.500 15.000 14.500 Piping Length (m) 4.200 4.000 3.800...
  • Page 49 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 13.500 12.500 11.500 10.500 9.500 8.500 Piping Length (m) 5.000 4.900 4.800...
  • Page 50 18.2 Heating Capacity Table 18.2.1 WH-UX09FE5 Water Out (°C) Input Input Input Input Input Input Capacity Capacity Capacity Capacity Capacity Capacity Outdoor Air (°C) Power Power Power Power Power Power 9000 3240 9000 3510 9000 3910 9000 4300 9000 4730 9000 5160 9000...
  • Page 51 18.3 Cooling Capacity Table 18.3.1 WH-ADC1216G6E5 WH-UX09FE5 Water In (°C) Water Out (°C) Outdoor Air (°C) Capacity (W) Input Power (W) Capacity (W) Input Power (W) Capacity (W) Input Power (W) 7000 1360 8550 1410 7000 1000 7650 1910 11100...