Diagnostics
7.1 LED displays
4 MCP software is running, no IE
5 MCP software is running, IE com‐
6 Error, e.g. incorrect configuration
*) LEDs in peripheral devices (keyboards, Powerrides and user keys connected to the digital outputs)
54
State
communication
munication established
or damaged USB peripheral
H1
H2
H4 PN
SYNC
FAULT
Off
Off
Off
0.5 Hz
Off
Off
4 Hz
4 Hz
4 Hz
Equipment Manual, 07/2020, A5E50324729B AA
H5 IE
H3 PWR
PER *)
Off
On
1 Hz
On
On
N/A
4 Hz
On
4 Hz
ONE MCP Part 1: MCP xxxx