Operating instructions Commercial air purifier PAC 1045/1080/1200 To avoid the risk of accidents or damage to the en-GB machine, it is essential to read these instruc- tions before it is installed and used for the first time. M.-Nr. 11 855 790...
Contents Caring for the environment .................... Disposing of filters......................Warning and Safety instructions..................Appropriate use ......................... Foreseeable misuse......................Technical safety......................... Description of the machine .................... Functional description ....................... Operation.......................... 10 Initial commissioning......................10 Operating the air purifier....................10 Control panel ......................... 11 Overview of operating modes ..................
Recycling the packaging material reduces the use of raw materials in the manufacturing process and also reduces the amount of waste in landfill sites. You can return the pack- aging to your Miele dealer. Disposal of your old appliance Electrical and electronic appliances often contain valuable materials. They also contain materials which, if handled or disposed of incorrectly, could be potentially hazardous to human health and to the environment.
Page 4
Caring for the environment Disposing of old batteries In many cases, electrical and electronic appliances contain batteries which must not be disposed of with household waste after use. You are legally obliged to remove any old bat- teries which are not securely enclosed by the appliance and take them to a suitable collec- tion point (e.g.
Warning and Safety instructions Please read the operating instructions before using the air purifier for the first time. They contain important information for your safety, as well as information on using and main- taining the air purifier. To avoid the risk of accidents or damage, it is essential to read the operating instructions carefully before using the appliance for the first time.
Do not operate the air purifier in humid areas at risk of explosion and/or areas with ag- gressive atmospheres. Do not make any alterations to the air purifier, unless authorised to do so by Miele. To ensure the correct performance of the air purifier and to prevent the risk of faults, it is important to carry out maintenance on a regular basis.
The plug must be easily accessible so that the air purifier can be disconnected from the power supply. If the mains connection cable is faulty it must always be replaced by a Miele authorised technician to protect the user from danger. ...
Description of the machine Lockable access flap Protects the air purifier controls against unauthorised access. Air intake vents On the left and right sides, rear and bottom of the plinth Lid with air outlet vents 4 adjustable feet 4 adjustable feet are supplied for optional stabilisation Control panel with display Operation with automatic and manual control.
Description of the machine Functional description The Miele air purifier draws in atmospheric air at the bottom via the air intake vents in the plinth (). The pre-filters () filter coarse dust out of the air. The air is conveyed upwards by the fan inside the air purifier and is pushed through the main filter and the active charcoal filter ().
Operation Initial commissioning Before carrying out initial commissioning, it is important to check that the air purifier is in- stalled in accordance with appropriate use guidelines. After installation, allow the air puri- fier to adjust to room temperature. Check the air purifier, the plug and the mains connection cable for damage. If there is any damage, the air purifier must not be used.
Operation Control panel Control panel behind the lockable access flap button button button Green LED Flashes when starting/ready for use, lights up during operation. Yellow LED CO Flashes in the event of a CO warning, lights up when heating is active. Red LED ...
Relevant pathogens are deactivated automatically by Miele ThermoControl after every use. Fan run-on The fan keeps running after Miele ThermoControl in order to cool the filter. Intensive circ. active The fan runs at a higher speed for a short period in order to quickly circulate the air within the room.
Press the button repeatedly until you reach the desired operating status. Tip: If you wish to clean the filter manually via Miele ThermoControl, press the button re- ThermoControl active peatedly until you reach the operating status. Relevant pathogens will then be deactivated in the filter by Miele ThermoControl.
menu. Press and hold the button for more than 3 seconds. Operating values display Operating hours 1245 Time to filter change Miele V01.1 PAC 1080 09.11.2020 14:28:00 Operating values display menu is now displayed. Operating values display Filter saturation Room temp.:...
6:00 am with 5 minutes of initial flow time, the air purifier will start at 5:55 am. After the switch-off time, Miele ThermoControl is started with a running time of 20 minutes. This is followed by a 10-minute fan run-on phase.
Operation Settings menu for “CO2 mode” Settings CO2 mode Room size Manual+time mode Room size CO2 mode Flow m² CO2+time mode Intensive circulation Please set CO2 mode Flow Flow speed Room size Flow 100% Intensive circulation Back Select option Please set Flow time Flow Back...
6:00 am with 5 minutes of initial flow time, the air purifier will start at 5:55 am. After the switch-off time, Miele ThermoControl is started with a running time of 20 minutes. This is followed by a 10-minute fan run-on phase.
Page 18
Operation Sensitivity sub-menu is used to set the sensitivity with which the controls respond to open windows when activating intensive circulation. High When is selected, intensive circulation is activated more quickly. When is selec- ted, it takes longer for intensive circulation to be activated when a window is open. If settings are configured, these settings will automatically be adopted for the other op- erating modes.
Date Time Date 10.12.2020 Service Please set Settings Date Service Change filter * For the Miele Customer Service Department only Settings menu for “Change filter/Factory defaults/Display contrast” Settings Change filter Reset filter time Service Reset filter time Change filter Back Back...
Installation Transport and installation Only personnel who have received instruction from the supervisor may transport and in- stall the air purifier. Risk of tipping during unsecured transport. There is a risk that the air purifier may tip over in the event of unsecured transport with incorrect transport equipment or lifting equipment.
Page 21
Installation Screw the 4 adjustable feet in a clockwise direction into the designated holes on the bot- tom of the air purifier. Risk of trapping if care is not taken when mounting the feet. When mounting the adjustable feet, there is a risk that fingers will be trapped accident- ally.
If the mains connection cable is damaged, it must only be replaced with a specific mains connection cable of the same type (available from the Miele Customer Service Depart- ment). For safety reasons, such replacement may only be carried out by a qualified spe- cialist or the Miele Customer Service Department.
The filter is expected to reach saturation after approx. 1–2 years (depending on site conditions, individual particle ingress and regular cleaning of the pre-filters). Miele therefore recommends regular maintenance by the Miele Customer Service Department. Fan settings for PAC 1045...
Page 24
Cleaning and care Fan settings for PAC 1080 Room size Flow rate for 6 air changes* Fan setting for 6 air changes (new Fan setting (%) for 6 air changes filter) (filter saturated – red LED lights up at 100 %) 25 m² 413 m³/h 45 % 60 %...
Contaminated filters must not be cleaned with solvent-based fluids and then reused in the air purifier. Contaminated filters must always be replaced with new ones. When replacing filters, only use accessory parts approved by Miele. If other parts are used, warranty, performance and/or product liability claims will be in- validated.
Pull the contact protection downwards and screw it back into place. Close the service flap and retighten the screws. Replacing the main filter and active charcoal filter Miele recommends having the main filter and the active charcoal filter replaced by the Miele Customer Service Department.
Page 27
Replacing the active charcoal filter (PAC 1045/1080) An active charcoal filter is fitted above the main filter. The active charcoal filter must be re- placed roughly every 6–12 months. Miele recommends having the active charcoal filter re- placed by the Miele Customer Service Department.
Page 28
Replacing the main filter The main filter (comprising particulate pre-filter G4 and high-performance filter H14) must be replaced roughly every 2 years in order to optimise operation of the air purifier. Miele recommends having the main filter replaced by the Miele Customer Service Department in order to guarantee that the air purifier is properly sealed afterwards.
Repair work to electrical appliances should only be carried out by an authorised techni- cian. Contact in case of malfunction In the event of any faults which you cannot remedy yourself, please contact your Miele Dealer or Miele Service. Contact information for Miele Service can be found at the end of this document.
Page 30
You can keep using the air purifier until the battery is re- been set (e.g. time, timer placed by the Miele Customer Service Department. Re- values). set the lost data via the Settings menu. The yellow LED flashes The CO2 limit has been reached or exceeded.
Page 31
The red LED flashes and The main filter no longer works and must be replaced. F2081 warning the message Contact the Miele Customer Service Department or re- is shown on the display. place the main filter (see “Cleaning and care – Filter re- placement”).
Technical data Model PAC 1045 PAC 1080 PAC 1200 Supply voltage 230 V 230 V 230 V Fuse rating (on site) 16 A ≥ 10 A 16 A ≥ 10 A 16 A ≥ 10 A Motor 780 W 780 W 1300 W Heating 1300 W 1300 W...
Page 34
United Kingdom Malaysia Miele Sdn Bhd Miele Co. Ltd., Fairacres, Marcham Road Suite 12-2, Level 12 Abingdon, Oxon, OX14 1TW Menara Sapura Kencana Petroleum Professional Sales, Tel: 0845 365 6608 Solaris Dutamas No. 1, Jalan Dutamas 1 E-mail: professional@miele.co.uk 50480 Kuala Lumpur, Malaysia Internet: www.miele.co.uk/professional...