Huawei eRRU Series Quick Installation Manual
Huawei eRRU Series Quick Installation Manual

Huawei eRRU Series Quick Installation Manual

Installation modes

Advertisement

Quick Links

eRRU Quick Installation Guide
In this document, eRRU3232 is used as an example. Difference in
installation and operation of other eRRU products are also described
eRRU Installation Modes
a
Common Requirements
CAUTION
• In all scenarios, the eRRU must be installed vertically.
• Do not stand the eRRU upright because the load-bearing capacity of the RF ports at the bottom of the eRRU is low.
• Place a foam pad or cardboard on the ground to protect the housing of the eRRU from damage before the binding.
b
Installing the eRRU on a Pole
Normal pole
推荐抱杆直径值为80mm
c
Installing the Mounting Kits on the Wall
NOTE
• For a single RRU, the wall can bear four
times of the weight of an RRU.
• Expansion bolts must be tightened to 30 N· m
to ensure that the bolts work properly and the
wall remains intact without cracks in it.
mm
Special pole
0
eRRU Installation Process
NOTE
Before installing the RRU, check the RRU and
accessories based on the equipment packing list and
ensure that all materials are complete.
Start
Unpack and Inspect the
Equipment
Install eRRUs on a
pole (slides 4 and
5)
Install RRU cables (slides 8
to 13)
Check the hardware
installation (slides 13 and 14)
Conduct power-on check
(slide 14)
End
V100R005C00 02
.
Install eRRUs on
the wall (slide 6)

Advertisement

loading

Summary of Contents for Huawei eRRU Series

  • Page 1 eRRU Quick Installation Guide V100R005C00 02 In this document, eRRU3232 is used as an example. Difference in installation and operation of other eRRU products are also described eRRU Installation Modes Common Requirements CAUTION • In all scenarios, the eRRU must be installed vertically. •...
  • Page 2 Installing eRRUs on a Pole (60 mm ≤ Pole Diameter ≤ 114 mm) Installing a single RRU 2. Loosen the two M10 nuts on the mounting 1. Determine a position for installing kits, and horizontally remove one end of the the mounting kits.
  • Page 3: Installing Two Rrus On A Pole

    Installing eRRUs on a Pole (60 mm ≤ Pole Diameter ≤ 114 mm) Installing two RRUs on a pole 1. Install the first RRU. 3. Interchange the cover plate in the front and the attachment plate and stainless steel screws at the rear of the second RRU. 4.
  • Page 4 Installing the eRRU Mounting Kits on the Wall 1. Place the auxiliary mounting bracket 2. Drill holes at the anchor points, and then against the installation position, use a insert expansion bolt assemblies. level to verify that the auxiliary mounting bracket is placed horizontally, and then mark anchor points with a marker.
  • Page 5 Installing eRRUs in Special Scenarios Installing an eRRU on a special pole(114mm ≤ Pole Diameter ≤ 220mm) Installing a single eRRU 2. Pass the hold hoop through the main 1. Determine a position for installing mounting bracket of eRRU. Mount the hold the hold hoop.
  • Page 6 Installing eRRU Cables(The eRRU3232 is taken as an example. Operations for other eRRU products are similar.) Installing the PGND Cable 1. Prepare an RRU PGND cable and add an OT terminal to each end of the cable. 2. Connect the M6 OT terminal at one end of the PGND cable to the ground terminal at the bottom of the RRU and the M8 OT terminal at the other end to the external ground bar.
  • Page 7 Installing eRRU Cables(The eRRU3232 is taken as an example. Operations for other eRRU products are similar.) Opening the Cabling Cavity 1. Loosen the screws on the cover plate 2. Open the cable clip. Cabling Cavity for the cabling cavity, and pull the hander to open the cover of the cabling cavity.
  • Page 8 Installing eRRU Cables Installing a CPRI optical fiber 1. Lower the puller of the optical module, insert an optical module into the CPRI0/IR0 port on the RRU, and raise the puller. CAUTION • The optical modules to be installed must match CPRI rates. •...
  • Page 9: Cable Connections

    Installing eRRU Cables Cable Connections Cable Connections for an eRRU3232 (DC) Cable Connections for an eRRU3232 (AC) RRU PGND RRU RF jumper CPRI optical fiber (CPRI0/IR0 RRU power cable cable port preferred) After the eRRU cables are installed ,ensure that the vacant cable troughs in the cabling cavity are insert waterproof blocks.
  • Page 10 Installing eRRU Cables Cable Connections eRRU3253 Cable Connections eRRU PGND cable eRRU RF jumper eRRU DC power cable CPRI optical fiber (CPRI0/IR0 port preferred) Closing the Cover Plate for an RRU Cabling Cavity CAUTION In indoor or outdoor scenarios, retain the dustproof caps on the unused antenna connectors and seal the connectors using the 1+3+3 waterproof method.
  • Page 11: Cable List

    Installing eRRU Cables Cable List Cable Connector Type Connected to... PGND cable and OT terminal (M6) RRU ground bolt equipotential cable (cable OT terminal (M8) External ground bar/ground bar of the surge protection box diameter greater than or equal to 16 mm Power cable Tool-less female connector (pressfit Power supply port on the RRU...
  • Page 12 Checking the eRRU Hardware Installation Checking the Cable Installation Check Item The PGND cable is green and yellow. The NEG (-) cable is blue and the RTN (+) cable is black. None of power cables and PGND cables can be short-circuited or reversely connected. Bind PGND cables, power cables, and signal cables separately.
  • Page 13 Appendix Hoisting the eRRU and Mounting Kits 1. Bind the RRU and the main and auxiliary mounting brackets properly using a lifting sling. Main mounting bracket Auxiliary mounting bracket CAUTION • When hoisting the RRU and mounting kits onto the tower, protect them from colliding with the tower.
  • Page 14 Appendix (The eRRU3232 is taken as Preparing the Tool-less Female Connector an example. Operations for other eRRU products are similar.) Appearance of the tool-less female connector (pressfit type) Tool-less female connector (pressfit type) -48 V DC power cable RTN(+) NEG(-) Shield layer 1.
  • Page 15 Appendix Sealing Connectors of RF Cables Using the 1+3+3 Waterproof Method Materials: waterproof tape and PVC insulation tape Wrap the first layer of PVC Wrap the connector with three insulation tape. layers of waterproof tape. 5 mm 105 mm Wrap the connector with three Bind the both ends of the tape by layers of insulation tape.
  • Page 16 Appendix Installing a Ground Clip for the Power Cable 1. Use a guarded blade utility to strip the sheath of the power cable about 63 mm to expose the shield layer. 2. Tightly wrap the copper of the grounding clip on the cable shield layer and tightly bind copper with cable ties.