Key Features
• Highly Expandable:
Up to 6 additional monitors can be connected to the main monitor using a combination of 7-inch wired monitors and 2.2-inch wireless monitors (However, the
maximum possible number of 7-inch wired monitors is 3). In addition, PBX connectivity is also supported.
• Wireless Monitor:
Using the wireless monitor, check visitors and respond promptly from the living room, kitchen and elsewhere in the home even while you
are doing something else. Up to 6 wireless monitors connectable. Max wireless range is 100 m with no obstacles. You can add on repeaters to expand the range.
Up to 2 DECT repeaters connectable.
• 7-inch Screen:
The main monitor and extension monitor have a 7-inch wide screen that offers easy viewing of wide vertical and horizontal views.
• Voice Change Function:
• Electric Lock Release Support for Gate:
The gate or door lock can be easily and quickly released using monitors (wired or wireless) from anywhere in the house.
• Picture Recording Function:
sessions. (up to 8 still images per visitor/session)
• Night Vision with LED lights (illumination lamp):
Door station is equipped with LED lights (illumination lamp). It enables the colour display of visitors at a distance of about 50 cm at night.
Wiring Schematic Diagram
DOORPHONE 1
MAIN MONITOR
NP
1
D1
2
D2
3
D3
4
D4
NP
5
Ml-1
6
Ml-2
7
MO-1
NP
8
MO-2
9
MO-3
NP
10
MO-4
11
MO-5
NP
12
MO-6
13
IN1
NP
14
IN2
15
IN3
NP
16
IN4
17
P1
NP
18
P2
NP
19
S1
20
S2
21
S3
22
S4
NP
Power plug
(220-240 V AC)
Power
supply
Electric lock
*1 When you use an additional doorphone, the maximum number of the electric locks that can be connected to the
doorphone depends on the type of doorphone. Consult your dealer for further information.
For VL-V554 users:
- Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.
*2 Connection devices for option input (A contact) can be used when a VL-V900 and VL-V700 series Video Intercom System
for Apartment Complexes is used.
- Make sure to connect emergency terminals to the IN1/IN2 terminals.
- Make sure to connect doorbells to the IN3/IN4 terminals. A doorbell and doorphone 2 cannot be used together.
*3 Connectable PBX Model Numbers: KX-TDA30/100/100D/200/600 series, KX-TDE100/200/600 series, KX-NS300/500/700/1000 series
Please consult your dealer when connecting with a PBX.
Accessory Information
For the Sub Monitor:
AC adaptor × 1 (PNLV226), Rechargeable batteries × 2, Charger × 1
For the Main Monitor Station/Extension Monitor:
Optional Accessories
Door Station
Door Station (Doorphone)
(Doorphone)
CMOS 1.0 M pixels
VL-V522L
VL-V554
(Surface mount)
VL-V554U
CMOS 0.3 M pixels
VL-V555
This function makes woman's voice (higher keys) sounds like a man's (lower keys).
The main monitor and extension monitor can record doorphone images from up to 50 doorphone calls or monitoring
*1
DOORPHONE 2
(Optional lobby station or Video
Intercom System for Apartment
Complexes can be connected.)
EXTENSION
5
Ml-1
6
Ml-2
MONITOR 1
EXTENSION
5
Ml-1
6
Ml-2
MONITOR 2
EXTENSION
5
Ml-1
6
Ml-2
MONITOR 3
Connection device for
option input
(A contact)
Terminal box
(4-conductor wiring)
Power
supply
PBX
*3
Electric lock
NP: Non-polarised
Mounting bracket × 1, Screw (4 mm x 16 mm) × 2
Extension Monitor
VL-MWD272
(Surface mount)
(Flash mount)
(Surface mount)
Wireless Video Intercom System
Wire type and length
*1
Wiring run
Doorphone –
Main monitor –
Extension monitor
*5
*6
Main monitor – Electric lock
Main monitor – Connection device
*6
for option input (A contact)
Main monitor – PBX
*4 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
• A certified power supply wiring has to be used with this equipment. The relevant national installation and/or
equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl
chloride flexible wiring according to IEC 60227 shall be used.
*5 When an extension monitor is used, make sure that the total wiring length from the doorphone to the main
*2
monitor and then to the extension monitor, is within about 100 m.
*6 When using an electric lock or a connection device for option input (A contact), select a device that meets the
following guidelines:
• Electric lock connection terminal (S1/S2, S3/S4):
- N/O dry closure contact
- 30 V AC (1 A)/24 V DC (1 A) or lower
• Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
- Input method: No-voltage contact
- Open-circuit voltage between terminals: DC 7 V or less
- Detection definite time: 0.1 seconds or more
- Short-circuit between terminals: 5 mA or less
- Resistance value: make: 500 Ω or less, break: 15 KΩ or more
For the Door Station:
Wireless
Monitor Station
(Sub monitor)
VL-WD613
VL-SWD272
VL-SVD272
VL-SVD272:
Wireless monitors sold separately
*4
Wire type
Diameter
Length (Max.)
φ 0.65 mm
22 AWG
φ 1.0 mm
18 AWG
φ 0.5 mm
CAT 5
φ 0.5 mm - φ 1.2 mm
According to the specification
of connected device.
(24 AWG - 17 AWG)
φ 0.5 mm - φ 1.2 mm
According to the specification
of connected device.
(24 AWG - 17 AWG)
φ 0.65 mm
CAT 3 or 22 AWG
Screw (3.8 mm x 20 mm) × 2
DECT Repeater
Lobby Station
VL-FKD2
Up to 20 main
monitors can
be connected.
100 m
130 m
50 m
100 m