Page 1
® ® ELECTRONIC ELECTRIC DRYER Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at... www.whirlpool.com ... 2 Table of Contents W10151580A...
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following: Read all instructions before using the dryer. Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
Optional Pedestal Are you placing the dryer on a pedestal? You have the option of purchasing pedestals of different heights separately for this dryer. You may select a 10" (25.4 cm) pedestal or a 15.5" (39.4 cm) pedestal with a shelf and bin dividers. These pedestals will add to the total height of the dryer for a total height of approximately 46"...
Page 5
Installation clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions 36" (91.4 cm) *28.65" (72.77 cm) 27" (68.6 cm) *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”...
Recommended installation spacing for cabinet installation For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. 7"* (17.8 cm) 7"* (17.8 cm) 5"** 28.65" 1"* (2.5 cm) (2.5 cm) (12.7 cm) (72.77 cm) *Required spacing **For side or bottom venting, 0"...
Page 7
Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection”...
Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector.
Page 9
Style 2: Direct wire strain relief Unscrew the removable conduit connector and any screws from a " (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening.
Page 10
2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw. A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.
Page 11
3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw. A. External ground conductor screw B. Ground wire (green or bare) of power supply cable C. ¾" (1.9 cm) UL listed strain relief D.
Page 12
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown. 1. Loosen or remove center silver-colored terminal block screw. 2.
10.2 cm 4" (10.2 cm) heavy metal exhaust vent DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section. Rigid metal vent For best drying performance, rigid metal vents are recommended.
Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. A. Dryer E. Clamps B. Elbow F. Rigid metal or flexible metal vent C. Wall G. Vent length necessary to connect elbows D.
Determine vent length and elbows needed for best drying performance Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will: Shorten the life of the dryer.
You can change your door swing from a right-side opening to a left-side opening, if desired. 1. Place a towel or soft cloth on top of the dryer or work space to protect the surface. Remove the door assembly 1. Remove the 4 screws that hold the door hinge on the front panel of the dryer.
7. Reassemble the inner and outer door assemblies with the 6 screws. Reverse the strike 1. Use a small flat-blade screwdriver to remove plug strip from the dryer door opening. Slide the head of the screwdriver under the plugs, being certain not to scratch the dryer surface.
WARNING Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Do not dry anything that has ever had anything flammable on it (even after washing). Failure to follow these instructions can result in death, explosion, or fire. WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance.
Auto Dry cycles take the guesswork out of drying time and enhance fabric care. The amount of time that is displayed is the estimated time remaining in the cycle. To use a Manual Cycle Point the dial to a Manual Cycle. Press TIMING Up or Down until the desired drying time is displayed.
WRINKLE SHIELD™ Feature The WRINKLE SHIELD™ feature light illuminates when this option is selected. This indicator stays on with the Cycle Complete light. Indicator lights Other indicator lights on the control panel show when Cycle, Temp Adjust, and End of Cycle settings are selected. Cycles Select the drying cycle that matches the type of load you are drying.
Additional Features WRINKLE SHIELD™ Feature The WRINKLE SHIELD™ feature helps smooth out wrinkles that form when you cannot unload the dryer promptly at the end of a cycle. During this option, the dryer stops tumbling and then tumbles again for a brief period. Press the WRINKLE SHIELD™...
To use the drying rack Do not remove the lint screen. 1. Open dryer door. A. Front edge 2. Place drying rack inside dryer drum, positioning the back wire on the ledge of the inner dryer back panel. Push down on front edge of drying rack to secure over the lint screen.
IMPORTANT: Do not run the dryer with the lint screen loose, damaged, blocked, or missing. Doing so can cause overheating and damage to both the dryer and fabrics. If lint falls off the screen into the dryer during removal, check the exhaust hood and remove the lint.
First try the solutions suggested here or visit our website and reference FAQs (Frequently Asked Questions) In U.S.A. www.whirlpool.com/help - In Canada www.whirlpool.ca Dryer Operation Dryer will not run Has a household fuse blown, or has a circuit breaker tripped? There may be 2 fuses or circuit breakers for the dryer.
Page 25
Are fabric softener sheets blocking the grille? Use only one fabric softener sheet, and use it only once. Is the exhaust vent the correct length? Check that the exhaust vent is not too long or has too many turns. Long venting will increase drying times. See “Plan Vent System.”...
Whirlpool designated service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States. To locate the Whirlpool designated service company in your area, you can also look in your telephone directory Yellow Pages. For further assistance...
If you need service, first see the “Troubleshooting” section of the Use & Care Guide. After checking “Troubleshooting,” additional help can be found by checking the “Assistance or Service” section or by calling Whirlpool. In the U.S.A., call 1-800-253-1301. In Canada, call 1-800-807-6777.