hit counter script
Download Print this page
Yamaha ARIUS YDP-S34 Midi Reference
Hide thumbs Also See for ARIUS YDP-S34:

Advertisement

Quick Links

YDP - S34
MIDI Reference

Table of Contents

MIDI Functions ....................................................................................2
MIDI Transmit/Receive Channel Selection....................................................................2
Local Control ON/OFF ..................................................................................................2
Program Change ON/OFF ............................................................................................3
Control Change ON/OFF ..............................................................................................3
Changing Song Playback Channels..............................................................................3
MIDI Data Format ................................................................................4
MIDI Implementation Chart .............................................................. 14
EN

Advertisement

loading

Summary of Contents for Yamaha ARIUS YDP-S34

  • Page 1: Table Of Contents

    YDP - S34 MIDI Reference Table of Contents MIDI Functions ..................2 MIDI Transmit/Receive Channel Selection..............2 Local Control ON/OFF ....................2 Program Change ON/OFF ....................3 Control Change ON/OFF ....................3 Changing Song Playback Channels................3 MIDI Data Format ................4 MIDI Implementation Chart .............. 14...
  • Page 2: Midi Functions

    MIDI communication between both devices. For instructions on how to connect this instrument to the computer, refer to the “Computer-related Operations” downloadable from the Yamaha Downloads website. MIDI Transmit/Receive Channel Selection In order to perform MIDI communication between this instrument and a computer, it is...
  • Page 3: Program Change On/Off

    MIDI Functions Program Change ON/OFF The information related to Voice changes is called “program change” in MIDI. Sending and receiving program change messages can be enabled or disabled as desired on this instrument. For example, if the relevant transmit and receive parameters are set to ON, Voice change information in this instrument can be transmitted to or received from a computer.
  • Page 4: Midi Data Format

    MIDI Data Format Preset Voice List Program Change # Voice Name (0-127) (0-127) (1-128) CFX Grand Mellow Grand Pop Grand Stage E.Piano DX E.Piano Harpsichord Vibraphone Pipe Organ Jazz Organ Strings YDP-S34 MIDI Reference...
  • Page 5 MIDI Data Format MIDI CHANNEL MESSAGE (1) Application Range MIDI, Internal Sequencer MIDI MIDI Status byte 1st Data byte 2nd Data byte Reception Transmission MIDI Panel MIDI Events Main Formats (main Status Data (Hex) Parameter Data (Hex) Parameter Song Layer Song* generation Left...
  • Page 6 MIDI Data Format MIDI CHANNEL MESSAGE (2) Application Range MIDI, Internal Sequencer NRPN (Non Registered Parameter Number) NRPN Data Entry MIDI Reception MIDI Transmission Panel MIDI Main Parameter Data Range (main Formats Song Layer Song* generation Left method)   ...
  • Page 7 MIDI Data Format MIDI PARAMETER CHANGE TABLE Application Range MIDI, Internal Sequencer Not Received when Receive Parameter SysEx is set to off. Not transmitted when Transmit Parameter SysEx is set to off. MIDI Parameter Change Table (XG SYSTEM) MIDI Reception MIDI Transmission Panel Address...
  • Page 8 MIDI Data Format MIDI Reception MIDI Transmission Panel Address Size Data XG Default Main Parameter Description (main Song Layer Song generation Left method) *2   00-7F CHORUS PARAMETER 5 *2   00-7F CHORUS PARAMETER 6  *2  ...
  • Page 9 MIDI Data Format MIDI Reception MIDI Transmission *The MULTI EQ Parameter cannot be Panel Address Size Main Data (H) Parameter Description reset to its factory (main Song Layer Song setting with XG generation Left SYSTEM ON. method)    01-78 EQ Q3 0.1...12.0...
  • Page 10 MIDI Data Format MIDI Parameter Change Table (MULTI PART) MIDI Reception MIDI Transmission Panel Address Size Data XG Default Main Parameter Description (main Song Layer Song generation Left method)     00-20 NOT USED     00-7F BANK SELECT MSB 0...127...
  • Page 11 MIDI Data Format     00-7F PAT LFO AMOD DEPTH 0...127     00-5F AC1 CONTROLLER NUMBER 0...95 (Voice)     28-58 AC1 PITCH CONTROL -24...0...+24 [semitones] 00-7F AC1 LOW PASS FILTER CONTROL -9600...0...+9450 [cent] ...
  • Page 12 F0 43 1n 4C hh mm ll dd ... F7  F0 = Exclusive status *Refer to *Refer to Parameter Change 11110000 01000011 43 = YAMAHA ID Parameter Change Table. 1n = Device Number n=always 0 (when transmit), n=0-F (when receive) Table. 0001nnnn 01001100...
  • Page 13 XG Parameter F0 43 3n 4C hh mm ll F7 Request 11110000 F0 = Exclusive status *Refer to 43 = YAMAHA ID Parameter Change 01000011 3n = Device Number n=always 0 (when transmit), n=0-F (when receive) Table. 0011nnnn 4C = Model ID...
  • Page 14: Midi Implementation Chart

    Yamaha [Digital Piano] Date : 10-AUG-2017 Model YDP-S34 MIDI Implementation Chart Version : 1.0 MIDI Implementation Chart Function... Transmitted Recognized Remarks Basic Default 1 - 16 Channel Changed Mode Default Messages Altered ************** Note 0 - 127 0 - 127...