Power scan automotive probe/scope 0-30v

Advertisement

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear eye
instruction
protection
manual
1. saFetY
iF You are in anY Doubt about eLectricaL saFetY consuLt a QuaLiFieD eLectrician.
only for use with 2V - 24V dc systems.
9
Do not apply voltage or current to the probe that exceeds the specified maximum of 30V dc.
8
Do not use on any circuit directly or indirectly connected to Ac lines or any other Ac power source.
8
Do not use with any component or circuits on the vehicle's ignition system.
8
Before using this device, check the vehicle's electrical wiring and disconnect any part or system sensitive to voltage and current pulses
9
such as air bags, electronic control modules, etc.
Always check the instructions and procedures indicated in the vehicle service manual before attempting to disconnect any part or
9
sub-system of the electrical circuit.
When not in use, store carefully in a safe, dry, childproof location. Avoid extremes of temperature.
9
Do not use the tool around explosive gases, vapour or dust. When the power switch is operated (forwards or backwards), voltage is
8
present at the tip of the probe which may cause sparks when contacting ground or certain other circuits.
Do not use leads if damaged or if the wire is bared in any way.
8
Do not use the equipment when you are tired or under the influence of alcohol, drugs or intoxicating medicines.
8
Do not use this tool for any purpose other than that for which it has been designed.
8
2. introDuction
Probably the most advanced automotive probe on the market, with a huge range of functions for effective automotive diagnostics, making short
circuits and bad earths easy to find. Features a scope function to visually test component signals, with the added benefit of maximum/minimum
volts, frequency and duty cycle displayed. Allows components to be activated in situ or prior to installation. The fly lead allows continuity and polarity
testing with a high-contrast colour LCD display giving a 7mm high read-out. Features audible and positive/negative voltage indicator and two
integral work lights. 6mtr lead connects to the battery supply and reaches all areas of the vehicle. includes a vehicle accessory socket adaptor and
6mtr extension cable. supplied in carry-case.
3. speciFication
model no: ............................................................... PP100.V2
dc voltage: .................................................................. 0-30V
frequency: ............................................................... 0-10KHz
duty cycle: ...................................................................1-99%
resistance: ..........................................................50Ω-199kΩ
continuity test audible: .................................................. <50Ω
scope function: ................................................................ yes
Back light: ........................................................................ yes
circuit breaker reset: ........................................................ yes
Key to fig.1
1 Probe tip – contacts the circuit or component to be tested.
2 Work lights – illuminate work area.
3 Red/Green Polarity Indicator – Identifies positive, negative or open circuits.
the red indicator lights when the probe tip is contacting a positive circuit.
the green indicator lights when the probe tip is contacting a negative circuit.
4 lcd display
5 circuit Breaker reset – resets the tool when the circuit breaker is tripped
6 Power switch – When operated conducts a positive or negative battery current
to the tip for activating and testing the function of electrical components.
7 mode Button – selects the work mode: dc voltage, scope, resistance &
audible indicator.
8 speaker – When the audible indicator is turned on, emits a tone.
9 Auxiliary Ground Lead
10 Adaptor – connects to the battery supply via clips or cigarette lighter adaptor.
© Jack sealey limited
instructions for
power scan automotive probe/scope
0-30v
pp100.v2
model no:
Original Language Version
fig.1
PP100.V2| Issue 1 13/06/17

Advertisement

Table of Contents
loading

Summary of Contents for Sealey PP100.V2

  • Page 1 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Operation

    When the probe tip contacts a NEGATIVE circuit, the green LED will light and the LCD screen will display the voltage to the nearest 0.1V. If the audible indicator is activated, a low pitched tone will emit (fig.8b). if the probe tip contacts an oPen circuit, neither led will function. Original Language Version PP100.V2| Issue 1 13/06/17 © Jack sealey limited...
  • Page 3: Continuity Testing

    Probe the contacts of the trailer’s electrical connection socket whilst pressing the power switch forward to the positive position. 5.5.5. this will allow you to check the function and orientation of the trailer lighting system. fig.13 Original Language Version PP100.V2| Issue 1 13/06/17 © Jack sealey limited...
  • Page 4 1mA current ensuring that the tool is safe for use as a multimeter or test light on sensitive ecu controlled electronic circuits such as the airbag circuit. Original Language Version PP100.V2| Issue 1 13/06/17 © Jack sealey limited...
  • Page 5: Maintenance

    Although designed to be a no maintenance tool, the power switch may deteriorate over a period of time through fair wear and tear. 6.1.2. replacement power switches are available through your sealey stockist and are simple to replace. 6.2. power switch replacement 6.2.1.

This manual is also suitable for:

Pp100