hit counter script
Sealey G2000I.V2 Instructions Manual
Sealey G2000I.V2 Instructions Manual

Sealey G2000I.V2 Instructions Manual

Inverter generator 2000w 230v 4-stroke engine

Advertisement

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
electrical
instructions
shock
hazard
1. safety
WarnIng! ensure any Health & safety, government, or local authority regulations are adhered to when using this equipment.
familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
9
maintain the generator in good condition (use an authorised service agent). replace or repair damaged parts. use genuine parts only.
9
unauthorised parts may be dangerous and will invalidate the warranty.
this generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application
9
for which it is not designed. if you have any questions regarding the application of the unit please contact your local sealey stockist.
WarnIng! Do not exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for
connection at any one time, the total must not exceed rated wattage of generator (see specifications).
WarnIng! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.
WarnIng! if you decide to use an earth leakage circuit Breaker (also referred to as an rcd or Ground fault circuit interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the
frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. this
connection should only be attempted by a qualified electrician, after first having consulted your local dealer.
Danger! this generator is designed for outdoor use only. to use the generator inside any building or enclosure, including the
generator compartment of a caravan, may result in fire or an explosion. no user performed modifications, including venting of the
exhaust and/or cooling ventilation, will eliminate the danger.
Danger! if this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the
commercial electric supply. failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a
back-feed of electrical energy.
Danger! the generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires,
terminals etc. never allow any unqualified person to operate or service the generator.
WarnIng! Petrol is highly flammable and petrol vapour is explosive. do not permit smoking, naked flames, sparks or heat in the
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. comply with all laws regulating storage and handling of fuels.
WarnIng! risk of burns. Do not touch the exhaust system or the drive unit.
WarnIng! never refuel when the engine is running or when the engine is hot. Allow cool down time.
operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
9
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
Do not tip or change the generator's position whilst it is operating.
8
remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
9
Keep non-essential persons and children away from the working area.
9
WarnIng! never start or stop the generator while electrical loads are connected. start the engine, let it stabilise, then connect the
electrical load. to stop engine, disconnect the electrical load and let engine stabilise before switching off.
WarnIng! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. to do so may result in electric
shock.
Do not use the generator for any purpose other than that for which it is designed.
8
Do not operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
8
Do not over-fill fuel tank. Always leave room for fuel to expand.
8
Do not operate in the rain.
8
Danger! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. the generator supplies the correct rated frequencies and voltage only when running at the
correct governed speed. incorrect frequency and/or voltage can damage some connected electrical loads.
operating at excessively low speeds may result in shortened engine life. over-speeding will invalidate the warranty.
Do not operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.
8
Do not store generator with fuel in tank where petrol vapours might reach an open flame or spark.
8
the generator must be grounded with a good quality insulated conductor.
9
Keep vents free from dirt etc.
9
If supplying electronic equipment, or in an area where electronic equipment is being used, keep the generator a sufficient distance
9
away to prevent electrical noise from the engine.
© Jack sealey limited
instructions for
Inverter generator 2000W 230v
4-stroke engIne
model no:
Hot surfaces
do not cover
Original Language Version
g2000I.v2
do not use in
switch off the engine
non ventilated
Before refuelling
area
G2000i.V2 | issue 1 05/09/16

Advertisement

Table of Contents
loading

Summary of Contents for Sealey G2000I.V2

  • Page 1 Do not attempt to modify the unit or use it for any application for which it is not designed. if you have any questions regarding the application of the unit please contact your local sealey stockist.
  • Page 2: Specification

    Ac Pilot light comes on when the engine starts and power is produced. 5.5. Dc protector the dc protector turns to “off” automatically when an electrical device connected to the generator is operating above the rated Original Language Version G2000i.V2 | issue 1 05/09/16 © Jack sealey limited...
  • Page 3: Operation

    WarnIng! the generator should be kept in an upright position ‰ when fuel is in the tank. recommended fuel........unleaded Petrol Fuel Tank Capacity.............4.0ltr. 6.2.1. To fill tank remove fuel tank cap and pour fuel into the tank fig.4 fig.3 up to the red line inside the filler tube fig.3. Maximum fuel level is shown in fig.4. 6.3. starting the engine 6.3.1. Turn the ECS switch (Bkack) to “OFF” fig.5. 6.3.2. Turn the air vent knob to “ON” fig.6. fig.6 fig.5 Original Language Version G2000i.V2 | issue 1 05/09/16 © Jack sealey limited...
  • Page 4 Original Language Version G2000i.V2 | issue 1 05/09/16 © Jack sealey limited...
  • Page 5: Maintenance

    Do not wring out the foam element when squeezing it, as this could cause it to tear. 7.4.6. Insert the foam element into the air filter case. Install the air filter case cover in its original position and tighten the screw. install the side cover and tighten the screws. fig.17 Original Language Version G2000i.V2 | issue 1 05/09/16 © Jack sealey limited...
  • Page 6 Drain the fuel 8.1.1. turn the engine switch to “stoP” 8.1.2. Remove the fuel tank cap and filter. Extract the fuel from the fuel tank into an approved fuel container. Replace fuel tank cap. 8.1.3. start the engine and leave it to run out of fuel. Approx 20min. 8.1.4. Remove the screws and cover fig.24. 8.1.5. Drain the fuel from the carburettor by loosening the drain screw on the carburettor float chamber. Original Language Version G2000i.V2 | issue 1 05/09/16 © Jack sealey limited...
  • Page 7: Troubleshooting

    Ac pilot light (Green) goes off..stop the engine and restart. parts support is available for this product. to obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. environmental protection recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

Table of Contents