FIP LEDs
The FIP LEDs are shown in Figure B-10. The upper row of three LEDs indicates the state of Phy B,
and the lower pair indicate the state of Phy A. (The Phy B interface is located above the Phy A
interface on the face of the FIP.) As with the other interface processors, the enabled LED goes on to
indicate that the FIP is enabled for operation.
The state of each B/A pair of LEDs indicates the status of one type of three possible station
connections: dual attachment station (DAS), single attachment station (SAS), or dual homed. The
states of the FIP LED combinations, and the meanings of each, are described and illustrated in
Table B-1.
Figure B-10
Table B-1
LED Pattern
FIP LEDs
FIP LED States—Refer to Figure B-10
1
State
B A
DAS
– –
Both LEDs off
X X
X X
O O
Both LEDs on
X X
X X
O –
B on and A off
X X
X X
Indication
Both LEDs off means not connected.
Not connected
Through A
Wrap B
Interface Processor LEDs
Reading LED Indicators B-273