Intended purpose and audience This manual contains the instructions for installing and maintaining this appliance. The audience for this ™ guide consists of those individuals responsible for installing IBM Cloud Object Storage System appliances. Note: • The equipment and device described for installation herein are sophisticated and relatively complex to install.
Suitability for telecommunication environment - This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Examples of a caution and a danger notice. Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229-9054, which is included with your product.
Environmental notices This information contains all of the environmental notices for IBM Systems products in English and other languages. The IBM Systems Environmental Notices information includes statements on limitations, product information, product recycling and disposal, battery information, flat panel display, refrigeration and water-cooling systems, external power supplies, and safety data sheets.
Page 11
Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation;...
Page 18
• Remove any jewelry or metal objects from your body. They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. 4 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 22
• Manual Remove packing materials on and in the appliance 1. Remove the tape warning on the top of the chassis that says: "Remove tape and foam before racking system." 8 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
2. Loosen the thumbscrews to either side of the faceplate for the appliance. 3. Open the faceplate. 4. Remove the packing foam from the inside of the faceplate. 5. Close the faceplate. 6. Tighten the thumbscrews. Appliance installation Attention: Allow the enclosure assembly to acclimate to room temperature before installation. Store the disk drives at room temperature for at least 2 hours before use.
Page 24
4. Slide the inner rail towards the front of the appliance to hold it in place. 5. Secure the rail to the appliance with the screws that are provided in the rail kit, as shown in the following figure. 10 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 25
Figure 5. Attaching the sections of the rack inner rails 6. Repeat these steps for the left inner rail. Install the outer rails 1. Measure the distance from the front rail to the rear rail of the rack. 2. Extend the left outer rail so that it fits snugly into the allotted distance. 3.
Page 26
Alternatively, use 2 - 4 individuals to place the appliance in position and begin inserting it into the rack rails. To install the appliance into the rack, do the following steps: 1. Line up the rear of the chassis rails with the front of the rack rails. 12 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 27
2. Slide the chassis rails into the rack rails, keeping the pressure even on both sides, as shown in the following figure. You might have to depress the locking tabs when inserting. When the appliance is pushed completely into the rack, you can hear the locking tabs click into the locked position. Figure 10.
The I/O ports are color-coded per the PC 99 specification. The locations of the various I/O ports are shown in the following figure. Figure 14. Rear panel I/O ports for the appliance 16 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Table 5. Legend for rear panel I/O Ports for the appliance Number Description Unused PCIe card slot (on riser card) 10 GbE NIC card Power supply 1 Power supply 2 UID button/LED 1 GbE RJ45 ports (2) 10/100 Mbit/s management port DB-15 video connector USB 2.0 ports (2) Network interface ports...
Page 32
Drive not installed. Drive is installed. Solid on Drive is selected/ Normal flashing identified. Drive is active. Fast flashing Drive failed. Solid on Drive is rebuilding. Slow flashing Normal flashing 18 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Procedure to replace a drive in the operating system/data RAID array. Before you begin In the Manager 3105 Appliance, the OS/data drives are in a RAID 5 configuration. This allows for one drive failure with no loss of data. Replacing a failed drive will automatically start the RAID rebuilding process.
7. Restart system and configure the network interface. For more information, see the Appliance Configuration Guide. Battery removal and installation Battery removal To remove the Onboard battery, follow these steps: 20 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 35
CAUTION: Handle used batteries carefully. Do not damage the battery in any way; a damaged battery can release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Refer to the IBM Systems Environmental Notices for battery disposal guidelines.
Page 38
47.625 x 83.82 x 17.78 (cm) Weight 157 (lbs) 71.214 (kg) Rail/extended 24/41.5 (in) 60.96/105.41 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 200-240 V AC, FREQUENCY 50-60 Hz 24 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 39
Table 14. General specifications (Slicestor 3448) (continued) S3448 Specification 2 hot-swappable 1100W PSUs in 1+1 configuration Table 15. Power measurements for Slicestor 3448 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.28 0.38 START 0.96 0.94 FULL 1050 0.99 1050 0.98 Table 16.
Page 40
Table 22. Power measurements for Slicestor 2448 w/ 8tb drives (FC:AJ10) 100v 240v Power(W) Power(W) 0.83 0.25 START 0.97 0.95 FULL 1100 0.99 1040 0.98 Table 23. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) 100v 240v Power(W) Power(W) 26 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 41
Table 23. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) (continued) 100v 240v 0.83 0.25 START 0.97 0.95 FULL 0.99 0.98 Table 24. General specifications (Slicestor 2212A) S2212A Specification Operating Temperature °C (°F) 10 to 35 degrees °C (50-95 degrees °F) Non - operating temperature °C (°F) -40 to 65 degrees °C (-40-158 °F) Operating humidity...
Page 43
27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 34. Power measurements for Manager 3105 100v 240v Power(W) Power(W) 0.36 0.94 START 0.96...
Page 44
Dimensions with front bezel (W x D x H) 19.000 x 27.625 x 1.750 (in) 48.26 x 70.1675 x 4.445 (cm) Weight 30.1 (lbs) 13.65313 (kg) Rail/extended 27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) 30 IBM Cloud Object Storage System: Manager 3105 Appliance Manual...
Page 45
Table 37. General specifications (Accesser 4105) (continued) A4105 Specification Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 38. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) 0.85 0.26 START 0.92 FULL 0.99...
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks. Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions. Notices 35...