Product manual
ABB-Welcome IP
D0401. Smart Access Point
D0401.-02 Smart Access Point

Advertisement

Table of Contents
loading

Summary of Contents for ABB D0401

  • Page 1 │ 2TMD041800D0088 30.10.2019 Product manual ABB-Welcome IP D0401. Smart Access Point D0401.-02 Smart Access Point...
  • Page 2: Table Of Contents

    Notes on the instruction manual ........................5 Safety ................................5 Intended use ..............................5 Typical application ..........................6 Environment ..............................8 ABB devices ............................8 Product description ............................9 Technical data ............................. 11 Mounting/Installation ............................ 12 Requirement for the electrician ......................12 Mounting ............................
  • Page 3 Table of contents 9.1.4 Configure outdoor stations ......................72 9.1.5 Configure guard unit ........................83 9.1.6 Configure IP actuator ........................85 9.1.7 Configure IPC ..........................90 9.1.8 Configure devices in batch ......................93 9.1.9 Removing devices ..........................95 User management ..........................96 9.2.1 Enter the settings ..........................96 9.2.2 Adding users ...........................97 9.2.3...
  • Page 4 Table of contents 11.7 Malware prevention solution ......................138 11.8 Default passwords and user accounts ................... 138 11.9 Password rule ..........................138 11.10 Logging ............................139 │4 Product manual 2TMD041800D0088...
  • Page 5: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
  • Page 6: Typical Application

    Intended use Typical application 1. Single family house If SmartAP is used in a single family house to control all devices in the house, it should be set to "Residential". IP camera Internet Slave IS Wifi Master IS Router switch SmartAP (Residential) Villa OS CAT.5/IP bus line...
  • Page 7 Intended use 2. High rise building If SmartAP is used in a high rise building to control all devices in this building, it should be set to "Functional". Building Master IS Master IS Apartment Slave IS Master IS Master IS Master IS Router Master IS...
  • Page 8: Environment

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 9: Product Description

    Product description Product description Function USB stick connector (reserved) Tamper switch Status indicator Binary input (used to interact with other systems) Binary output (used to interact with other systems) Reset button Press and hold this button for 10 s to reset the password of the first admin. Please see the "Reset the password for the first admin"...
  • Page 10 Product description Status indicator Description Blue Green White Priority Flashing Reset to factory default 7 (Highest) slowly Flashing Alarm (e.g. tamper alarm) quickly Power on or Initial setup Flashing AP mode is enabled slowly Security mode is disable Doorbell is muted Normal operation │10 Product manual 2TMD041800D0088...
  • Page 11: Technical Data

    Technical data Technical data Designation Value Rating voltage 24 V DC Operating voltage range 20-27 V DC Rating current 24 V DC, 375 mA PoE standard IEEE802.3 af 802.11b/g/n: 2412...2462MHz (for United States) 2412...2472MHz (for European countries) 802.11a/n: Wireless transmission band 5150…5250MHz 5250…5350MHz 5470…5725MHz...
  • Page 12: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 13: Mounting

    Mounting/Installation Mounting 1. Dismantle Pull the clamp on the bottom of the device and then open the front cover. 2. Wiring Option 1: Wiring from the back Option 2: Wiring from the bottom Option1 Option2 │13 Product manual 2TMD041800D0088...
  • Page 14 Mounting/Installation 3. Mounting │14 Product manual 2TMD041800D0088...
  • Page 15: Commissioning

    Commissioning Commissioning Registering an account on the MyBuildings portal Öffnen Sie den Link: https://mybuildings.abb.com und klicken Sie auf „Registrieren“. Füllen Sie das Formular aus, um ein Benutzerkonto anzulegen. Aktivieren Sie Ihr Benutzerkonto, wenn Sie die E-Mail vom MyBuildings-Portal erhalten. │15...
  • Page 16: Access Smartap

    Commissioning Access SmartAP 8.2.1 Access SmartAP through UPnP PC must connect to the router first. Router Router Router SmartAP SmartAP SmartAP Wifi connection LAN connection Please follow the steps below on the PC: │16 Product manual 2TMD041800D0088...
  • Page 17: Access Smartap Through Ap Mode

    Commissioning 8.2.2 Access SmartAP through AP mode SmartAP works in AP mode ■ SmartAP enters AP mode automatically when it is powered on for the first time and LED light white. SmartAP enters AP mode automatically after initial setup and LED flashes red. ■...
  • Page 18 Commissioning Obtain original WLAN name and password Open the front cover of SmartAP, you can find the original WLAN name and password on a sticker. 105807A7F02D590 Sma rtAP N e tw o rk se tti n g s WLAN: SmartAP_xxx x PW: xxxxxxx xxx C N E 105807A7F02D 590...
  • Page 19 Commissioning On PC, enter the IP address of AP mode (default is "192.168.3.1") to access SmartAP. You need to enter new IP address if you change it on the "Wi-Fi access point mode settings" screen. │19 Product manual 2TMD041800D0088...
  • Page 20: Initial Setup

    Commissioning Initial setup 1. Switch to security login It is recommend to use HTTPS to encrypt data. Click "Switch to security login" - "Advanced" - "Proceed to …" to switch to security screen. │20 Product manual 2TMD041800D0088...
  • Page 21 Commissioning 2. Select language Select the language from the list. 3. Accept end user license │21 Product manual 2TMD041800D0088...
  • Page 22 Commissioning 4. Accept OSS license 5. Accept data privacy │22 Product manual 2TMD041800D0088...
  • Page 23 Commissioning 6. Choose building type Please see the "Typical application" chapter for more details. 7. Define your location Select time zone from the drop-down list. │23 Product manual 2TMD041800D0088...
  • Page 24 Commissioning 8. Change AP mode Wi-Fi setting and set country code It is forced to change the WLAN name and password on initial setup. It is recommended to make a new sticker and affix it to the cover of the device. │24 Product manual 2TMD041800D0088...
  • Page 25 Commissioning 9. Select connection type Select a connection type according to the diagram below. Switch Router Router SmartAP SmartAP SmartAP (Funcitonal) (Residential) (Residential) Connection type = Wifi Connection type = LAN Selection type = LAN │25 Product manual 2TMD041800D0088...
  • Page 26 Commissioning Selection type = Wi-Fi 10. Create the first admin user Here you create the first admin user. │26 Product manual 2TMD041800D0088...
  • Page 27 Commissioning 11. MyBuildings login [1] Security lever 1: Reset the password for the first admin without MyBuildings account Description If you don’t make any settings on this screen, you can click "Skip" to access next screen. If you do not have a MyBuildings account, click "register here" to create one. Enter the user name, password and friendly name If "Remote access"...
  • Page 28 Commissioning [2] Security lever 2: Reset the password for the first admin with MyBuildings account Description If you do not have a MyBuildings account, click "register here" to create one. Enter the user name, password and friendly name Enter the email for resetting the password for the first admin If the "Remote access"...
  • Page 29 Commissioning Click "Connect" and you will receive an email with the verification code. Enter this verification code and click "√". Please see the "Reset the password for the first admin" chapter for more details. │29 Product manual 2TMD041800D0088...
  • Page 30 Commissioning 12. Set the device name This device name will be displayed on the log in screen. 13. Confirm the settings You can see all the settings on the overview screen. Click "Finish" if the settings are OK. │30 Product manual 2TMD041800D0088...
  • Page 31 Commissioning 14. Access log in screen Description Device name User name and password Access configuration screen This function is only available for the admin user and master user. Switch to security login │31 Product manual 2TMD041800D0088...
  • Page 32: Home Screen

    Commissioning Home screen 8.4.1 Configuration screen Description Quick setting Click "∨" to access quick settings on a drop-down sidebar. Notification Available notifications are displayed by means of a red dot. The digit indicates the number of available messages. Please see the "Notification" chapter for more details. Message center Manage the messages between the indoor stations and SmartAP.
  • Page 33 Commissioning Description User management Please see the "User management" chapter for more details. Actions Please see the "Create actions" chapter for more details. Time control Please see the "Time control" chapter for more details. Configure the devices on Door entry system Please see the "Configure the devices on Door entry system "...
  • Page 34: Settings

    Commissioning Settings 8.5.1 Access quick settings On the configuration screen, click "∨" to access quick settings. │34 Product manual 2TMD041800D0088...
  • Page 35: Access General Settings

    Commissioning 8.5.2 Access general settings On the configuration screen, click "Preferences" to access the settings. │35 Product manual 2TMD041800D0088...
  • Page 36: Version Information

    Commissioning 8.5.3 Version information On the "Preferences", "System information" screen, you can view the version information │36 Product manual 2TMD041800D0088...
  • Page 37: Disclaimer Information

    Commissioning 8.5.4 Disclaimer information On the "Preferences", "System information" screen, you can view the disclaimer information. │37 Product manual 2TMD041800D0088...
  • Page 38: Language

    Commissioning 8.5.5 Language On the "Preferences", "Localization" screen, select the language from the drop-down list. │38 Product manual 2TMD041800D0088...
  • Page 39: Time Settings

    Commissioning 8.5.6 Time settings Time zone setting On the "Preferences", "Localization" screen, select time zone from the drop-down list │39 Product manual 2TMD041800D0088...
  • Page 40 Commissioning Sync SmartAP time with local system or NTP server On the "Preferences", "Localization" screen, SmartAP time can be set to sync from "Local system time" or from "NTP time service". │40 Product manual 2TMD041800D0088...
  • Page 41 Commissioning Sync SmartAP time with other devices on the system On the "Preferences", "Misc settings" screen, you can select "Automatically" to sync SmartAP time with other devices on the system regularly. You need to click "Apply" before the change is effective.
  • Page 42: Network Settings

    Commissioning 8.5.7 Network settings On the "Preferences", "Network settings" screen, you can change the network settings. Please see the "Initial setup" chapter for more details. │42 Product manual 2TMD041800D0088...
  • Page 43: Ap Mode Settings

    Commissioning 8.5.8 AP mode settings On the "Preferences", "Wi-Fi AP mode settings" screen, you can change the AP mode settings. │43 Product manual 2TMD041800D0088...
  • Page 44: Third Part Authority Settings

    Commissioning 8.5.9 Third part authority settings On the "Preferences", "Third party authority" screen, click "add" and enter the IP address and the port number, then click "Applied" to apply the setting. │44 Product manual 2TMD041800D0088...
  • Page 45: Abnormal Devices

    Commissioning 8.5.10 Abnormal devices On the "Preferences", "Abnormal devices" screen, you can view the details of abnormal devices (e.g. device sign failed, communication failed etc.). You can check the device when "Device signed failed" appears on the abnormal devices list. ■...
  • Page 46: Onvif Ipc Settings

    Commissioning 8.5.11 Onvif IPC settings Indoor station can’t use "Community monitor" function before IPCs are set here. On the "Configuration", "Protocol", "Protocol info" screen of the IPC, protocol must be set to "Onvif". On the "Configuration", "Stream", "Base Stream" screen of the IPC, "Video Encode type" must be set as "H264"...
  • Page 47 Commissioning On the "Configuration", "Device", "Local Network" screen of the IPC, turn off DHCP and set the IP address to 10.0.0.x. │47 Product manual 2TMD041800D0088...
  • Page 48 Commissioning On the "Preferences", "Onvif IPC list" screen of SmartAP, click "Search device" to search the cameras used for the public network. Then click "Enter credentials" after the IPC is detected. │48 Product manual 2TMD041800D0088...
  • Page 49 Commissioning Enter the user name and the password of the camera, then click "Pair". │49 Product manual 2TMD041800D0088...
  • Page 50: Alarm Notification Settings

    Commissioning 8.5.12 Alarm notification settings On the "Preferences", "Misc settings" screen, the sound notification and popup notification are only available when the "Alarm when devices goes offline" function is enabled. Note The alarm is reported via outdoor station 1 (device ID=1) or via gate station 1 (device ID=1).
  • Page 51: Mybuildings Settings

    Commissioning 8.5.13 MyBuildings settings "Pair" is displayed when the account and password are correct. "Connect" is displayed when SmartAP is connected to the MyBuildings portal successfully. If "Remote access" is enabled, you can access SmartAP on the MyBuildings portal. But you need to subscribe to the "Remote access"...
  • Page 52 Commissioning Refresh the license You can refresh the license after the remote service is subscribed. On the "Preferences", "MyBuildings", "License" screen, click " " to refresh the license. │52 Product manual 2TMD041800D0088...
  • Page 53: Project Backup

    Commissioning 8.5.14 Project backup 1. Create a backup On the "Preferences", "Project backups" screen, click " ", enter the name and description, then click "Save" to create a backup onto the SmartAP. │53 Product manual 2TMD041800D0088...
  • Page 54 Commissioning 2. Restore the backup On the "Preferences", "Project backups" screen, click a backup, then click "Restore project backup". 3. Export the backup to PC On the "Preferences", "Project backups" screen, click a backup, enter a recovery password and then click "Export" to export the backup to PC. Note This recovery password is set by you and it is used to import back the same backup from the PC.
  • Page 55 Commissioning 4. Import the backup from PC On the "Preferences", "Project backups" screen, click " ", enter the recovery password and upload the backup form PC, click "√" to restore the backup. The system will restart when the database has been restored. │55 Product manual 2TMD041800D0088...
  • Page 56: Restore To Default Settings

    Commissioning 8.5.15 Restore to default settings On the "Preferences", "Service" screen, click "Restore default settings", then select the settings to be restored. Description Reset the data set on "Actions" and "Time control". Reset the data set on "Preference" - "MyBuildings". Clear the data set on "User management".
  • Page 57 Commissioning You need to enter the verification code to continue the operation if SmartAP is set to security level 2. Please see the "Mybuilings login" chapter for more details. │57 Product manual 2TMD041800D0088...
  • Page 58: Firmware Update Of Smartap

    Commissioning 8.5.16 Firmware update of SmartAP 1. Download SmartAP firmware On the "Preferences", "Firmware update" screen, you can click the link "on the website" to download the firmware of SmartAP from the website or you can tick the checkbox to download the firmware automatically.
  • Page 59: Reset The Password For The First Admin

    Commissioning 8.5.17 Reset the password for the first admin Press and hold the reset button for 10 s. R e se t b u tto n AP mo d e sw i tch L ED 1. Security level = level 1 You can change the password for the first admin directly.
  • Page 60 Commissioning 2. Security level = level 2 You will receive an email containing the verification code sent by SmartAP. You need to enter the verification code to continue to change the password for the first admin. │60 Product manual 2TMD041800D0088...
  • Page 61: Operation

    Operation Operation Device management 9.1.1 Adding DES devices Note Only a device without a certificate can be added by SmartAP. This device will lose its certificate if its physical address is changed. All the devices need to be powered on before being added. There are 3 methods to add a DES devices to SmartAP.
  • Page 62 Operation Method 2: Add the devices manually On the configuration screen, click "Door entry system", "Add device", select the device type (e.g. gate station) and enter the address ID and serial number of the device, then click "Save". │62 Product manual 2TMD041800D0088...
  • Page 63 Operation Method 3: Import the devices from APP The mobile/tablet (APP) must be in the same network with the router connected to SmartAP. On the "MAIN MENU" screen of the management software, click " ", a pop-up window will appear. │63 Product manual 2TMD041800D0088...
  • Page 64 Operation On the "Projects" screen of mobile/tablet, swipe the project name to the right, click " ", select a designated SmartAP and enter the account and password of SmartAP, then click "Log in". On the configuration screen of SmartAP, a pop-up window shows the importing status. │64 Product manual 2TMD041800D0088...
  • Page 65: Adding Videocontrol Devices

    Operation 9.1.2 Adding VideoControl devices On the configuration screen, click "Device configuration" to access the corresponding screen. Please follow the steps below to add an IPC. │65 Product manual 2TMD041800D0088...
  • Page 66: Configure Indoor Stations

    Operation 9.1.3 Configure indoor stations On the configuration screen, click "Door entry system", "Indoor stations", then click an indoor station to access the settings. │66 Product manual 2TMD041800D0088...
  • Page 67 Operation Basic information Function Device ID Click the icon to return to the previous screen Overview of the indoor station Display the physical address of the indoor station Display the logical address of the indoor station Display the first name and last name of the resident Display the serial number of the indoor station Display the version of the indoor station │67...
  • Page 68 Operation Additional settings Function Set the physical address of the indoor station Set the logic address of the indoor station Duplicate the settings to another indoor station Local firmware update Online firmware update Set the resident data Upload a screensaver image to the indoor station Upload a floorplan to the indoor station Set the language of the indoor station │68...
  • Page 69 Operation Duplicating the settings on another indoor station Select the indoor stations and the settings to be duplicated, click "Save" to duplicate the settings from the current indoor station to the designated indoor stations. Local firmware update Click "Browser" and select the update file and the signature file form local PC, then click "Save" to update the firmware.
  • Page 70 Operation Online firmware update The router connected by SmartAP must connect to the internet before use. Upload a screensaver image Go back to the indoor station, select "Screensaver", click "Browser" and select an image (only .jpg is supported, maximum resolution of the image is 1024 x 600 pixels), click "Save" to send this image to the indoor station.
  • Page 71 Operation Upload a floor plan Click "Browser" to select a floorplan image (only .jpg is supported, maximum resolution of the image is 1024 x 600 pixels), click "Save" to upload the floorplan. Setting the language Select the language from the drop-down list, then click "Save" to save the setting. │71 Product manual 2TMD041800D0088...
  • Page 72: Configure Outdoor Stations

    Operation 9.1.4 Configure outdoor stations The following description uses the IP touch 5 outdoor station as an example. On the configuration screen, click "Door entry system", "Outdoor stations", then click an outdoor station to access the settings. │72 Product manual 2TMD041800D0088...
  • Page 73 Operation Basic information Function Device ID Click the icon to return to the previous screen Overview of the outdoor station Device type of the outdoor station Display the address of the outdoor station Display the serial number of the outdoor station Display the version of the outdoor station │73 Product manual 2TMD041800D0088...
  • Page 74 Operation Additional settings Funciton Set the physical address for the outdoor station Set the calling type for the outdoor station, please see the "Set the calling type" chapter for more details. Set the welcome message for the outdoor station Set the door lock time for the outdoor station, please see the "Set the door lock time" chapter for more details.
  • Page 75 Operation Set the calling type Tick the "Name list" checkbox, the outdoor station will start a call via the name list. Untick the "Name list" checkbox, the outdoor station will start a call via the keypad. Next, you can select "Physical address" or "Logical address" from the drop-down list. Set the welcome message Enter the text and click "Save", and the setting will be reflected on the screen of the outdoor station.
  • Page 76 Operation Set the door lock time It the default lock type is set to "IP actuator", you need to add the outdoor station to the trusted list of IP actuators. Please see the "Set the IP actuator" chapter for more details. │76 Product manual 2TMD041800D0088...
  • Page 77 Operation Set the trusted devices You need to enable the "Trust this management software" function if you want this outdoor station to unlock in the event of an emergency. Please see the "Emergency unlock" chapter for more details. Click "Add trusted devices" to add the devices to the outdoor station. For example, you want the guard unit and the indoor stations to release the lock of this outdoor station, you need to add them to the trusted list.
  • Page 78 Operation Set the welcome screen There are 2 functions for setting the welcome screen. [1] Developer information Click "Development information", select an image or enter the words. The result will be displayed on the screen of the outdoor station. │78 Product manual 2TMD041800D0088...
  • Page 79 Operation [2] Bulletin Click "Bulletin", "Add bulletin page", "Upload image/logo" to upload a logo or a word. This logo or word will be displayed on the screen of the outdoor station. A maximum of 3 bulletins can be uploaded. The outdoor station plays the bulletins one by one and each bulletin is displayed for 10 s.
  • Page 80 Operation Manage the name list 1. Add the name list There are 2 ways to add the name list Method 1: Import the name list Click "Import name list entries" and select the designated indoor stations. Then click "Import". │80 Product manual 2TMD041800D0088...
  • Page 81 Operation Method 2: Add the contacts one by one Please follow the steps below to add the contact. │81 Product manual 2TMD041800D0088...
  • Page 82 Operation 2. Copy the name list to the other outdoor station Click "Copy name list to other OS", select the destination outdoor stations, and click "Import". 3. Remove the name list Click "Remove all entries", then click "Continue" to clear the name list. │82 Product manual 2TMD041800D0088...
  • Page 83: Configure Guard Unit

    Operation 9.1.5 Configure guard unit On the configuration screen, click "Door entry system", "Guard unit", click a guard unit to access the settings. │83 Product manual 2TMD041800D0088...
  • Page 84 Operation Function Device ID Click the icon to return to the previous screen Overview of the guard unit Device number of the guard unit Display the serial number of the guard unit Display the version of the guard unit Update the firmware via local PC, please refer to the "Set the indoor station" chapter for more details.
  • Page 85: Configure Ip Actuator

    Operation 9.1.6 Configure IP actuator On the configuration screen, click "Door entry system", "IP actuator", click an IP actuator to access the settings screen. │85 Product manual 2TMD041800D0088...
  • Page 86 Operation Function Device ID Click the icon to return to the previous screen Overview of the IP actuator Set device type of the IP actuator (e.g. network IPA, building IPA and private IPA) Display the physical address of the IP actuator Display the serial number of the IP actuator Display the version of the IP actuator Set the lock connected to the IP actuator...
  • Page 87 Operation Set the lock connected to the IP actuator │87 Product manual 2TMD041800D0088...
  • Page 88 Operation Set the trusted devices for the IP actuator You need to enable the "Trust this management software" function if you want this IP actuator to unlock in the event of an emergency. Please see the "Emergency unlock" chapter for more details.
  • Page 89 Operation Release the IP actuator connected to the outdoor station If the default lock type of the outdoor station is set to "IP actuator", you need to select an IP actuator. This outdoor station must be added to the trusted list of IP actuator in advance. │89 Product manual 2TMD041800D0088...
  • Page 90: Configure Ipc

    Operation 9.1.7 Configure IPC On the configuration screen, click "Device configuration" to access the corresponding screen. │90 Product manual 2TMD041800D0088...
  • Page 91 Operation On the "Device configuration" screen, click "IP camera", click an IP camera to access the settings screen. Description Serial no. and CPU version of the IPC. Click to update the firmware to the latest version. Click to set the IPC step by step. Click to go to the IPC website IP address of the IPC.
  • Page 92 Operation More settings of the IPC │92 Product manual 2TMD041800D0088...
  • Page 93: Configure Devices In Batch

    Operation 9.1.8 Configure devices in batch You can configure several devices at the same time. Fox example, on the "Indoor stations" screen, click " ", click the devices directly or click "select all" to select all the devices, then click "Next". │93 Product manual 2TMD041800D0088...
  • Page 94 Operation You can click "Local firmware update" to update the firmware for these devices. You can click "Screensaver" to upload a screensaver image for these devices. │94 Product manual 2TMD041800D0088...
  • Page 95: Removing Devices

    Operation 9.1.9 Removing devices You can remove a device or several devices at the same time. Fox example, on the "Outdoor stations" screen, click " ", click the devices directly or click "select all" to select all the devices, then click "Delete". │95 Product manual 2TMD041800D0088...
  • Page 96: User Management

    Operation User management 9.2.1 Enter the settings On the configuration screen, click "User management" to access the settings. │96 Product manual 2TMD041800D0088...
  • Page 97: Adding Users

    Operation 9.2.2 Adding users On the "User management" screen, follow the steps below: │97 Product manual 2TMD041800D0088...
  • Page 98: Configuring Users

    Operation 9.2.3 Configuring users On the designated user screen: Description Change first name and last name of the user Change the password of the user Assign the users to the user group or remove the users from the user group. Assign the ID authentications to the user or remove ID authentications from the user.
  • Page 99: Removing Users

    Operation 9.2.4 Removing users On the designated user screen, click " " to delete the user. │99 Product manual 2TMD041800D0088...
  • Page 100: Adding A User Group

    Operation 9.2.5 Adding a user group You can add a user group so that everyone in the group has the same permissions. On the "User management" screen, follow the steps below: │100 Product manual 2TMD041800D0088...
  • Page 101: Configuring A User Group

    Operation 9.2.6 Configuring a user group On the designated user group screen: Description Assign the users to the user group or remove the users from the user group. Assign the locks to the user group or remove the locks from the user group. │101 Product manual 2TMD041800D0088...
  • Page 102: Removing A User Group

    Operation 9.2.7 Removing a user group On the designated user group screen, click " " to delete the user group. │102 Product manual 2TMD041800D0088...
  • Page 103: Assigning The Users To A User Group

    Operation 9.2.8 Assigning the users to a user group On the designated user group screen, follow the steps below: │103 Product manual 2TMD041800D0088...
  • Page 104: Removing The Users From A User Group

    Operation 9.2.9 Removing the users from a user group On the designated user group screen, follow the steps below: │104 Product manual 2TMD041800D0088...
  • Page 105: Assigning Id Authentications To A User

    Operation 9.2.10 Assigning ID authentications to a user On the designated user screen, follow the steps below: │105 Product manual 2TMD041800D0088...
  • Page 106 Operation Registered ID authentications by card no. If ID authentications are registered by card no., the "safe mode" function needs to be set to "Disabled" on IP touch 5 outdoor station before use. │106 Product manual 2TMD041800D0088...
  • Page 107 Operation Register by outdoor station (recommend) Swipe the ID authentications on the outdoor station when the prompt window appears. │107 Product manual 2TMD041800D0088...
  • Page 108: Removing Id Authentications From A User

    Operation 9.2.11 Removing ID authentications from a user On the designated user screen, follow the steps below: │108 Product manual 2TMD041800D0088...
  • Page 109: Assigning The Locks To A User

    Operation 9.2.12 Assigning the locks to a user On the designated user screen, following the steps below, the ID authentications assigned to this user can release all locks assigned to this user. │109 Product manual 2TMD041800D0088...
  • Page 110: Assigning The Locks To A User Group

    Operation 9.2.13 Assigning the locks to a user group On the designated user group screen, following the steps below, the ID authentications assigned to this user can release all locks assigned to this user. │110 Product manual 2TMD041800D0088...
  • Page 111: Removing The Locks From A User

    Operation 9.2.14 Removing the locks from a user On the designated user screen, follow the steps below: │111 Product manual 2TMD041800D0088...
  • Page 112: Removing The Locks From A User Group

    Operation 9.2.15 Removing the locks from a user group On the designated user screen, following the steps below, │112 Product manual 2TMD041800D0088...
  • Page 113: Pairing App To A User

    Operation 9.2.16 Pairing APP to a user 1. SmartAP access MyBuildings portal On the configuration screen, follow the steps below: │113 Product manual 2TMD041800D0088...
  • Page 114 Operation You need to subscribe to the remote service on the MyBuildings Portal before "Refresh license" is executed. │114 Product manual 2TMD041800D0088...
  • Page 115 Operation 2. SmartAP access "Pairing devices" screen On the designated admin screen, click "Pairing devices" and wait for APP operations. │115 Product manual 2TMD041800D0088...
  • Page 116 Operation 3. Pairing SmartAP on APP Note APP and SmartAP must not be in the same network. Internet 3G/4G Router SmartAP On the home screen of APP, click "∨" and following the steps below, │116 Product manual 2TMD041800D0088...
  • Page 117 Operation 4. SmartAP enter token code │117 Product manual 2TMD041800D0088...
  • Page 118: Removing App From A User

    Operation 9.2.17 Removing APP from a user │118 Product manual 2TMD041800D0088...
  • Page 119: Creating Actions

    Operation Creating actions 9.3.1 Enter the settings On the configuration screen, click "Actions" to access the corresponding screen. │119 Product manual 2TMD041800D0088...
  • Page 120: Creating A New Action

    Operation 9.3.2 Creating a new action For example, you want to go on vacation from 2019.10.1 to 2019.10.7 and you need the IPC to take a snapshot when the door fails to release. Please follow the steps below to create this action. 1.
  • Page 121 Operation 3. Add actuator 4. Add notification │121 Product manual 2TMD041800D0088...
  • Page 122: Configuring The Action

    Operation 9.3.3 Configuring the action On the actions screen, click " ", change the name or click the icon to enable/disable the action. = enable; = disable │122 Product manual 2TMD041800D0088...
  • Page 123: Removing The Action

    Operation 9.3.4 Removing the action On the actions screen, click " " to delete the action. │123 Product manual 2TMD041800D0088...
  • Page 124: History

    Operation History On the configuration screen, click to access the corresponding screen. A maximum of 16,000 records (including notifications, alarms and logs) are supported. 9.4.1 Notification A notification can be set when you create an action. When the action is activated, SmartAP will receive a notification and save this to the history.
  • Page 125 Operation On the "Notification", "Notification" screen, you can view the notifications. Description Number of unread messages Number of total messages Highlighting indicates unread status. Details of the message. Close the view of detailed message. Delete the message. Filter the messages by keywords. Filter the messages by date.
  • Page 126: Alarm Record

    Operation 9.4.2 Alarm record On the "Notification", "Alarm" screen, you can view the alarm records. Description Number of unread messages Number of total messages Highlighting indicates unread status. Details of the message. Select a solution between "Processed" and "False alarm". Comment for the alarm.
  • Page 127: Logs

    Operation 9.4.3 Logs On the "Notification", "logs" screen, click a log, you can view the call records, unlock records and events (e.g. action is triggered or other setting operations). Description Number of unread messages Number of total messages Highlighting indicates unread status. Details of the message.
  • Page 128: Message Center

    Operation Message center 9.5.1 Access "Message center" screen On the configuration screen, click " " to access the corresponding screen. │128 Product manual 2TMD041800D0088...
  • Page 129: Creating And Sending A Message

    Operation 9.5.2 Creating and sending a message On the "Message center" screen, click "+" to set a receiver, then enter the subject and the message, click "√" to create and send the message. │129 Product manual 2TMD041800D0088...
  • Page 130: Viewing And Replying To A Message

    Operation 9.5.3 Viewing and replying to a message On the "Message center" screen, click "Inbox" to view the message received from the indoor stations. You can click on a message and reply to it directly. A maximum of 1000 messages is supported. Your reply messages can be viewed in the "Outbox".
  • Page 131: Emergency Unlock

    Operation Emergency unlock Note SmartAP must be added to the trusted list on the outdoor stations, gate stations and Public IP actuators before this function is used. On the configuration screen, click "SOS" and enter the user password, click "Unlock all public doors"...
  • Page 132: Online Firmware Update

    Operation Online firmware update On the configuration screen, click " ", you can find the devices to be updated on a pop-up window. Click "Update all" to update all devices. │132 Product manual 2TMD041800D0088...
  • Page 133: Fcc

    │133 Product manual 2TMD041800D0088...
  • Page 134: Cyber Security

    11.1 Disclaimer D0401. devices are designed to be connected and to communicate information and data via a network interface, which should be connected to a secure network. It is the customer's sole responsibility to provide and continuously ensure a secure connection between the product and...
  • Page 135 Cyber security Port and service Port Service Purpose HTTP web service HTTPS web service 5222 Service for XMPP client 5280 Service for XMPP HTTP administrator service 5281 Service for XMPP HTTPS administrator service 49152 UPnP 1900 UPnP service 31002 Searched for & managed PC client tools 7000 Private protocol service 10700...
  • Page 136: Deployment Guideline

    Cyber security 11.3 Deployment guideline Please do not install it within a public place and ensure that physical access to the devices is granted only to trusted person. It is not recommended to use HTTP (unencrypted data transfer) outside of secure, private networks.
  • Page 137: Data Pursing

    Cyber security 11.6 Data pursing In case of quitting from the working system (e.g. replaced by another device, re-install in another system…), All the data stored in the device need to be purged by the “Restore default setting” in webpage as below, Login in the web page by admin user account.
  • Page 138 Cyber security 11.7 Malware prevention solution The device D0401. is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is by firmware upgrading. Only firmware signed by ABB can be accepted.
  • Page 139 Cyber security 11.10 Logging The device has a logging system which can log some events, which contains, ■ Changing settings ■ Adding/changing/removing other devices ■ Adding/changing/removing user accounts (including information and access rights) ■ Updating/patching software firmware Accessing to devices, such as unlock, record, snapshot, etc. ■...
  • Page 140 We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
  • Page 141 Km 9 National Highway 1A , The detailed specifications agreed P.O.Box 11070 Dubai-UAE Hoang Liet, Hoang Mai, Hanoi, upon apply for orders. ABB accepts T : +971 4 3147 586 Vietnam no responsibility for possible errors F : +971 4 3401 541 T : +84 4 3861 1010 or incompleteness in this document.
  • Page 142 Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. © Copyright 2019 ABB All rights reserved │142 Product manual 2TMD041800D0088...