hit counter script

Installing A Gigabit Ethernet Module (Gem); Second-Generation Switch; Virtual Port Channel Migration - Migration Of Nodes From A First-Generation Switch To A Second-Generation Switch - Cisco Nexus 93600CD-GX Hardware Installation Manual

Aci-mode switch
Hide thumbs Also See for Nexus 93600CD-GX:
Table of Contents

Advertisement

Installing a Gigabit Ethernet module (GEM)

The leaf switch is connected to each spine switch in the ACI fabric.
Step 6
Repeat Steps 1 through 5 for each leaf switch in the ACI fabric.
Each leaf switch in the ACI fabric is connected to each spine switch in the network,
The fabric automatically implements Equal Cost Multi-Pathing (ECMP) and enables all links. You do not
need to configure the links.

Installing a Gigabit Ethernet module (GEM)

Step 1
Clear the switch's current configuration by using the
Step 2
Power off the switch by disconnecting the power.
Step 3
Replace the current GEM card with the new GEM card.
Step 4
Power on the switch.
Virtual Port Channel Migration - Migration of Nodes from a
First-Generation Switch to a Second-Generation Switch
Initially the fabric is configured with vPCs between two first-generation switches. Traffic flows are designed
so that only these vPCs are used for data traffic. Now that you want to migrate both of the first-generation
switches to second-generation switches, the following steps are required.
For this procedure, vPC primary and vPC secondary are first generation switches in vPC pair, sending traffic
as described above.
To determine which transceivers, adapters, and cables that this switch supports, see
http://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-device-support-tables-list.html.
To see the transceiver specifications and installation information, see
http://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-installation-guides-list.html.
Before you begin
You have two first-generation Cisco Nexus 9000 Series switches comprising a virtual port channel (vPC).
You are migrating to two second-generation Cisco Nexus 9000 Series switches using the same cables.
First-generation Cisco Nexus 9000 Series switches include those switches that do not contain an EX or an
FX in the PID (product identification).
Second-generation Cisco Nexus 9000 Series switches include those switches that have an EX or an FX in the
PID.
Move any APIC controllers that are connected to the migrating vPC first-generation switches to any other
switches in the fabric and wait for the APIC cluster to become "Fully Fit".
Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide
28
command.
setup-clean-config
Connecting the Switch to the ACI Fabric

Advertisement

Table of Contents
loading

Table of Contents