CP 5613 A2/CP 5614 A2
SIMATIC NET
PG/PC - PROFIBUS
CP 5613 A2/CP 5614 A2
Operating Instructions
08/2016
C79000-G8976-C301-02
___________________
Preface
___________________
Description of the device
___________________
Software installation
___________________
Hardware installation
___________________
Configuration
___________________
Technical specifications
___________________
Certification
1
2
3
4
5
6
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET CP 5614 A2

  • Page 1 ___________________ CP 5613 A2/CP 5614 A2 Preface ___________________ Description of the device ___________________ SIMATIC NET Software installation ___________________ Hardware installation PG/PC - PROFIBUS CP 5613 A2/CP 5614 A2 ___________________ Configuration ___________________ Technical specifications Operating Instructions ___________________ Certification 08/2016 C79000-G8976-C301-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Preface ..............................5 Description of the device ......................... 9 CP 5613 A2 product characteristics ..................9 CP 5614 A2 product characteristics ..................11 PROFIBUS interface ....................... 12 Meaning of the LED display ....................13 Software installation ..........................15 Installing the "SIMATIC NET PC Software"...
  • Page 4 Table of contents CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 5: Preface

    ● Certificate of license Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. Validity of this documentation These operating instructions are valid for the following products: ●...
  • Page 6 → Entry list → Entry type "Manuals / Operating Instructions" Trademarks The following and possibly other names not identified by the registered trademark sign ® are registered trademarks of Siemens AG: SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614, CP 5622...
  • Page 7 Preface Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc.
  • Page 8 Preface CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 9: Description Of The Device

    Description of the device CP 5613 A2 product characteristics CP 5613 A2 characteristics The CP 5613 A2 is a communications processor for connecting PCs to PROFIBUS. The essential characteristics are as follows: ● The CP 5613 A2 is equipped with a PROFIBUS interface allowing up to 12 Mbps. It is intended for operation in PGs and PCs with a PCI bus interface according to the PCI standard V2.2.
  • Page 10 Description of the device 2.1 CP 5613 A2 product characteristics CP 5613 A2 appearance The following figure shows the CP 5613 A2 communications processor: Yellow and green status LED PROFIBUS interface 1 (master or slave) CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 11: Cp 5614 A2 Product Characteristics

    Description of the device 2.2 CP 5614 A2 product characteristics CP 5614 A2 product characteristics CP 5614 A2 characteristics The CP 5614 A2 is a communications processor for connecting PCs to PROFIBUS. It has the same characteristics as the CP 5613 A2, as well as: ●...
  • Page 12: Profibus Interface

    You will find information about the structure of a PROFIBUS network in the system manual "PROFIBUS Network Manual". The document is part of the Manual Collection. You will also find this on the Product Support pages under the following entry ID: 35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591) PIN assignment The D-sub female connector has the following pin assignment:...
  • Page 13: Meaning Of The Led Display

    Description of the device 2.4 Meaning of the LED display Short name Meaning Input/output RTS output signal of the CP module. The control signal is "1" Output active when the device (PG or PC) is sending. Shield The shield is connected to components of the connector hous- ing.
  • Page 14 Description of the device 2.4 Meaning of the LED display CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 15: Software Installation

    Install the software as described in the installation manual "SIMATIC NET PC Software". You will find this installation manual on the Product Support pages under the following entry 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) You should also note the current information on the "SIMATIC NET PC software" on the Product Support pages: Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
  • Page 16: Uninstalling The "Simatic Net Pc Software

    "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 17: Hardware Installation

    Hardware installation Safety notices WARNING Electric shock possible - work only when the power supply is off Opening the PG/PC and plugging or pulling the communications processor is permitted only when the power is off. Turn off your PG/PC and pull the power cable connector before you start the hardware installation.
  • Page 18: Installing Hardware

    Hardware installation 4.2 Installing hardware Installing hardware Permitted number of communications processors in the PG/PC The driver software supports a maximum of 4 communications processor per PG/PC. 4.2.1 Automatic adaptation of the bus clock speed Automatic adaptation of the bus clock speed The communications processor is designed for a bus clock speed of 66 MHz.
  • Page 19: Hardware Compatibility

    Hardware installation 4.3 Hardware compatibility 7. Insert the power plug into the socket again and turn your PG/PC on. The plug and play function of Windows automatically searches for a driver. 8. Follow the instructions of the Hardware Wizard of Windows. Do not activate the search for drivers on the Internet.
  • Page 20 Hardware installation 4.3 Hardware compatibility CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 21: Configuration

    Configuration Configuring To be able to configure the communications processor, the following engineering or configuration tools are available: ● STEP 7 V5.5 ● STEP 7 Professional (TIA Portal) ● Communication Settings (COML S7) The steps involved are described in the "Commissioning PC Stations" manual or in the relevant online helps.
  • Page 22 Configuration CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 23: Technical Specifications

    Technical specifications Technical specifications for CP 5613 A2/CP 5614 A2 Construction Values Module format PC card, short PCI format Dimensions (H x W x D) in mm 107 x 18 x 168 Weight CP 5613 A2: 105 g CP 5614 A2: 120 g Bus interface PCI V2.2, plug and play Voltage...
  • Page 24 Technical specifications Interfaces Mode of the PROFIBUS interface Floating (interface signals), non-floating (cable shield) PROFIBUS controller used CP 5613 A2 / CP 5614 A2 • Master: ASPC2R ST E2a CP 5614 A2 • Slave: DPC31 Data transfer Transmission speed 9.6 kbps ... 12 Mbps Electromagnetic compatibility (EMC) Emission Class B to EN 55022...
  • Page 25 Technical specifications Mechanical environmental conditions Vibration during operation tested to DIN EN 60068-2-6 during operation 10 to 58 Hz, amplitude 0.0375 mm; 58 to 500 Hz, acceleration 4.9 m/s² 3 axes Shock during operation Tested to DIN EN 60068-2-27 during operation half sine: 50 m/s²...
  • Page 26 Technical specifications CP 5613 A2/CP 5614 A2 Operating Instructions, 08/2016, C79000-G8976-C301-02...
  • Page 27: Certification

    Declaration of conformity You will find the declaration of conformity for this communications processor on the Product Support pages under the following entry ID: 58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997) C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard according to EN 61000-6-3.
  • Page 28 ● Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

This manual is also suitable for:

Simatic net cp 5613 a2

Table of Contents