Sealey TA203.V2 Instructions Manual

Sealey TA203.V2 Instructions Manual

Digital automotive analyser 15 function bar graph/pc link

Advertisement

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
1.1.
PERSONAL PRECAUTIONS
! When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current.
Protection of the meter against misuse.
! Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine Sealey
leads with the same electronic ratings. Failure to do so will invalidate the warranty.
" DO NOT use leads if damaged or if the wire is bared in any way.
1.2.
GENERAL SAFETY INSTRUCTIONS
! Familiarise yourself with the application and limitations of the meter as well as the potential hazards. IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
! When the meter is linked to a measurement circuit, do not touch unused meter terminals.
! When the scale of the value to be measured is unknown set the selector to the highest range available.
! Before rotating the range selector to change functions, disconnect test leads from the circuit under test.
# WARNING! Never perform resistance measurements on live circuits.
! Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers while measuring.
! When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -10
! Never apply voltage or current to the meter that exceeds the specified maximum.
Input Limits
Function
Terminal
AC Volts
V - Ω - RPM
DC Volts
Frequency
V - Ω - RPM
Ohms (Resistance)
V - Ω - RPM
Diode Test
AC/DCµ AmA
µ A/mA
20A AC/DC (30 secs
20A
max every 15 minutes)
RPM
Duty Cycle (%)
V - Ω - RPM
Dwell Angle
WARNING! Do Not make current measurements on the 20A
#
scale for longer than 30 seconds in every 15 minutes.
Exceeding 30 seconds may cause damage to the meter and
test leads.
WARNING! Ohms can not be measured if a voltage is present.
#
Only measure in non powered circuits.
2.
FEATURES
Extra large, hi-contrast LCD display with 36mm high digital read-out, bar graph and backlight. Durable bi-composite case with probe storage and integral
stand, suitable for the toughest workshop conditions. Features millisecond pulse-width function for accurate measurement of fuel injection systems.
Includes auto ranging, data hold and auto power off. Supplied with inductive coupler with adjustable sensitivity, for fast reading of engine rpm, test leads
(probe and clip) and thermocouple plus interface cable and software for downloading data to PC.
Meter Functions
Voltage . . . . . . . . . . . . . .(V AC/DC)
Resistance . . . . . . . . . . . .(Ω)
Diode Check . . . . . . . . . .(
)
Audible Continuity . . . . . .(
)
AC or DC Current . . . . . .(A)
Temperature . . . . . . . . . . .(Temp °C & °F)
Frequency . . . . . . . . . . . .(Freq)
Dwell . . . . . . . . . . . . . . . .(
Duty Cycle . . . . . . . . . . . .(%)
Ms - Pulse & ms - Period .(ms)
RPM . . . . . . . . . . . . . . . .(
Maximum Input
750V AC rms
1000V DC
250V AC/DC
250V AC/DC
400mAAC/DC
20AAC/DC
250V AC/DC
Fig.2
)
)
INSTRUCTIONS FOR: DIGITAL AUTOMOTIVE ANALYSER 15
FUNCTION BAR GRAPH/PC LINK
MODEL:TA203.V2
C to 50
C.
O
O
FIG. 1.
Layout: ( Refer to fig. 1. )
1.
Large LCD display
2.
Max/Min/RS232 Button
3.
Relative Button
4.
Data Hold/Back Light Button
5.
Rotary selector Switch
Volts, Ω, Hz, %, RPM, CAP, ms,
6.
DWELL and TEMP Terminal
7.
Com Terminal
8.
mA Terminal
9.
20A Terminal
10.
Range/#CYL Button
11.
± TRIG Button
12.
Mode/RPM, 2, 4 stroke Button
TA203.V2 - 1 - 200807

Advertisement

Table of Contents
loading

Summary of Contents for Sealey TA203.V2

  • Page 1 Protection of the meter against misuse. ! Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.
  • Page 2: Specification

    0.5A/250V, 5 x 20mm fast acting ceramic type. Dimensions: 197 (H) x 88.4 (W) x 41.2 (D) mm. Weight Approx: 635g including holster. Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity. TA203.V2 - 1 - 200807...
  • Page 3: Operation

    4.10.1. Insert the black test lead into the negative “COM” jack and the red test lead into the positive “V” jack. 4.10.2. Turn the rotary switch to the CAP position. 4.10.3. Touch the test probes to the ends of the capacitor and read the capacitor value on the display. TA203.V2 - 1 - 200807...
  • Page 4: Other Functions

    4.18.5. After driver installation, a new COM port will be added to the "Ports (COM &LPT)" section in the Device Manager. Within this section you will find a device called "CP2101 USB to UART Bridge Controller" and next to it in brackets will be the (COM#), remember this number for entry into the data logging application. TA203.V2 - 1 - 200807...
  • Page 5 4.18.8. Click button "A" (FIG.5) to toggle between available COM ports until the COM# in window "B" (FIG.5) matches the number found in the device manager in step 4.18.5. fig.5 The program is now ready to capture data from the TA203.V2. For more details on using the program please refer to the document located in "C:\Program Files\9995" called "9995.rtf".
  • Page 6: Maintenance

    2002/96/EC WEEE Directive For Jack Sealey Ltd. Sole UK importer of Sealey Professional Tools. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.