GSMHS Installation and Setup Guide Registering through AlarmNet Direct Website ....................4-1 Using the Tamper Switch ........................... 4-2 Using the Programming Tool ..........................4-2 Replacing an existing module using the programming tool ................4-3 Register by Phone............................... 4-3 SECTION 5: Programmer Keyboard Commands................. 5-1 Programmer Keyboard Commands ...........................
In addition to alarm reporting, the GSMHS provides upload/downloading capability of Honeywell's control panel data over the Internet (via the AlarmNet-i network), using GSM (Global System for Mobile) technology.
Reports are sent in ADEMCO High-Speed format 4204 Mode and Two-4204 Mode This mode is for use with Honeywell controls that do not support LRR-ECP communication, but do support 4204 Relay Modules The module connects to the control’s keypad terminals ...
GSMHS Installation and Setup Guide MOUNTING SCREW (4) CASE (TYP) BACK INTERNAL ANTENNA WALL OR MOUNTING SURFACE OPTIONAL WIRING T E R KNOCKOUT S E ! V IC IT LE TE LE N S M 77 20 TR A .5 V - 16 C 56 CASE...
Check the Installation and Setup Guide for the control panel you are using to see if it supports ECP communication. Connect the GSMHS to a compatible Honeywell VISTA control panel's ECP terminals, in parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc.
Page 12
GSMHS Installation and Setup Guide TRANSFORMER AC INPUT 1 AC INPUT 2 + TRIGGER ZONE INPUT Z1/Z2 (VOLTAGE: 6-12V) BATTERY COMMUNICATIONS TRIGGERING DEVICE MODULE Figure 2-3. Wiring the GSMHS Zone 1 Input for a Positive (+) Trigger TRANSFORMER AC INPUT 1 AC INPUT 2 TRIGGER ZONE INPUT Z1/Z2...
Section 2: Mounting and Wiring Wiring for Module Fault Relay You may wire and program the module's fault output trigger for fail-safe mode (see the question "FLT REL ON Y/N"). To sense a module fault at the control panel, make connections as shown in Figure 2-6, including the proper EOL resistor required by the control.
GSMHS Installation and Setup Guide Backup Battery Connection The included battery (K14139) is used for backup in the event of a system power loss. The battery can provide over 24 hours of system life in the event of a power failure. ...
S E C T I O N Programming the GSMHS General Information The GSMHS is designed to deliver alarms via the GSM network to an AlarmNet central station when it is registered with a valid AlarmNet account.
GSMHS Installation and Setup Guide Using the AlarmNet Direct Website To program the module via the website (if you are already signed up for this service), go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx If you are not signed up for this service, click on “Dealer Sign-Up.” Log in and follow the on-screen prompts.
Section 3: Programming the GSMHS [3]: For entering the number 3 [C]: For entering letter C [4]: For entering the number 4 [D]: For entering letter D [5]: For entering the number 5 [E]: For entering letter E [6]: For entering the number 6 [F]: For entering letter F [7]: For entering the number 7 [S]: For entering letter S...
Page 18
GSMHS Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION [Y], [N] To begin programming the module, press [Y] and go to Program Device? Prompt 9: "Device Mode." (Y/N)_ To create a password if none has been assigned, press [N] and go to Prompt 4: "Create Password." To change an existing password, press [N] and go to Prompt 5: "Change Password."...
Page 19
Section 3: Programming the GSMHS PROMPTS ENTRY OPTIONS DESCRIPTION Applicable only if control supports Central Station #1 [Y], [N] En. 2 CS Y/N and #2 Category Enable reporting for the LRR device (N)_ (e.g., VISTA-128BP, FA1660C, etc.). Used if reporting to a second central station is desired. If [N], go to Prompt 17: "Device Address."...
Page 20
GSMHS Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION If enabled, the fault open collector output is normally [Y], [N] Flt Rel ON Y/N energized to ground, and de-energizes (open circuit) in (N)_ the event of a module fault. For conditions that trip the fault relay refer to Module Supervision Features in Section 1.
Page 21
Section 3: Programming the GSMHS PROMPTS ENTRY OPTIONS DESCRIPTION (V+) Selects the triggering method for this zone input. Zn7 Trigger Type (V–) Press the [space] key to scroll through choices. (V+)_ (EOLR) Inverts the alarm and normal states of the zone 7 [Y], [N] Invert Zn7 Y/N trigger;...
Zone Trigger Mode. 4204 Emulation Mode In 4204 Emulation Mode, the GSMHS communicates with a compatible Honeywell VISTA series or First Alert control panel as though it were a 4204 Relay Module. If two 4204s are enabled in the module, it acts as two 4204s at consecutive device addresses. The control panel must be configured to recognize one or two 4204 relay modules accordingly.
Section 3: Programming the GSMHS 4204 Emulation Mode Options For control panels that do not support LRR-ECP communication, the 4204 Emulation modes provide a means of sending up to eight unique reports based on defined system conditions. In 4204 mode, the GSMHS functions as a logical 4204 Relay Module, where each relay number, referred to in the module as zone number, can be programmed to send a report based on the output function programmed in the control for that relay.
Page 24
GSMHS Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. [Y], [N] To begin programming the module, press [Y] Program Device? and go to Prompt 9: "Device Mode." (Y/N)_ To create a password if none has been assigned, press [N] and go to Prompt 4: "Create Password."...
Page 25
Section 3: Programming the GSMHS 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. [0001- Enter the 4-digit subscriber account number, Primary Sub ID 9999] 0001-9999 (decimal). (????) The GSMHS communicates with the control [01-15] Device Address panel as a 4204 relay module. Enter the (12)_ appropriate address.
Page 26
GSMHS Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. In the event the module detects a communica- [01-99] GSM Flt Time tion path failure, enter the time delay (in [00] = not (1 min)_ minutes) before the module notifies the control used panel with a trouble message (and trips the...
Page 27
Section 3: Programming the GSMHS 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. Input Trigger Types: Triggering of each zone input can be programmed to cause an alarm under one of the following conditions: (V+), where a positive voltage causes an alarm for normally low connections (voltage trigger, NO, NC) ...
Page 28
GSMHS Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. Enter the zone number to be used for Zone Trig: Open/Close Zone open/close (arm/disarm) reports. This zone [3-7] (0)_ assignment must be unique from the Telco 4204: [1-4] zone selected in Prompt 25.
Page 29
Section 3: Programming the GSMHS 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. [01-15] Defines the reporting delay in seconds for Delay Zn3 (secs) zone 3. [00] = no (00) UL: Must be set to “00.” delay Reports alarms on zone 3 ONLY if the [Y], [N] ...
Page 30
GSMHS Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. [Y], [N] Enables restore reporting for zone 6. Restore Zn6 Y/N UL: Must be set to “Y.” (Y)_ [01-15] Defines the reporting delay in seconds for ...
Log in and follow the on-screen prompts. If you are not signed up for this service, click on “Dealer Signup” from the login screen to gain access to the Honeywell web-based programming. Dealer Sign-Up Direct Link: https://services.alarmnet.com/AlarmNetDirectP_Sign-Up. You will be instructed how to proceed upon completing the sign-up form. Only one sign-up per dealer is required.
GSMHS Installation and Setup Guide 2. Primary Central Station ID (two-digit hexadecimal number) 3. Primary Subscriber ID (four-digit number) 4. MAC ID and MAC CRC number (located on outside of box and on label inside module) or MIN number of the device you are replacing. Once module is registered, you may log out of the AlarmNet Direct website.
Section 4: Registration Possible Errors Displayed if this is a repair/replacement, or an error was made in Registration BAD programming the Primary account information of GSMHS for an Pri ID – Need PIN existing account. This prompt appears for 2 seconds. See the Replacing an existing module section below for further displays.
GSMHS Installation and Setup Guide GSM Status Displays GSM Status Display Screen 1 PriRSSI GPRS REG -xxxdbm PriRSSI – Primary Site RSSI level in dbm GPRS – GPRS Service availability where “x” can be: “Y” if GPRS is available “N” if GPRS is Not available –...
Page 39
5555555 5 ++ OK The status display includes: Zone input status (1234567) - the numbers 1-7 represent the 7 mappings of the zone input, and follow Honeywell's ADEMCO high-speed format codes: 1 = New Event 5 = Normal X = Not Enabled ...
Page 40
GSMHS Installation and Setup Guide Line Voltage Display Line Voltage The line voltage of the GSMHS can be viewed on the xx.xxV 7720P. An asterisk (*) next to the voltage indicates that this is below the accepted level. Press the [Space] key to go back to the System Status Display.
Appendices Appendix A: Summary of LED Operation Status Display Operation The Status Display has three LEDs used to indicate message and device status:...
Page 42
GSMHS Installation and Setup Guide Table A-1. Status Display Operation LED COLOR DESCRIPTION GREEN STATUS ON – GSMHS is NOT registered with AlarmNet. OFF – GSMHS is registered with AlarmNet. FAST BLINK – Download session with Compass in progress. SLOW BLINK – In unison with yellow LED – Registration in progress.
Appendices Signal Strength (RSSI) / Mode and Status LEDs The Signal Strength (RSSI) / Mode and Status LEDs normally display the module’s signal strength. LED 1 (red LED on the left) will be lit to indicate that the display is in RSSI mode, and the other LEDs indicate signal strength (lowest to highest, from left to right) between the module and the receiving tower.
Page 44
GSMHS Installation and Setup Guide Table A-4. Status Indications LED 4 LED 5 LED 6 STATUS green) green) green) No GPRS service GSM module not registered with Normal available network carrier GSM module registered—second SLOW BLINK – – site available–low signal strength GSM module registered—second NORMAL –...
Appendix C: GSM Downloading General Information The GSMHS can be used to provide high-speed up/downloading to Honeywell VISTA control panels over the Internet (via the GPRS network). This allows site maintenance independent of central station monitoring, and modification to sites globally. At this time, some control panels support downloading through the ECP bus and some control panels support downloading through the use of a Direct Wire connection.
DSL – Digital Subscriber Line ECP – Enhanced Console Protocol, which is a proprietary communications bus used in Honeywell VISTA control panels for wiring additional keypads and peripheral devices; consists of a four-wire data bus (power+/-, data in/out). Gateway IP Address – A gateway (sometimes called a router) is a computer and/or software used to connect two or more networks (including incompatible networks) and translates information from one network to the other.
Page 54
FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 55
GSMHS Summary of Connections INTERNAL ANTENNA MOUNTING STATUS LED HOLE (TYP.) MESSAGE LED FAULT LED FOR EXTERNAL ANTENNA 50 OHM MMCX ONLY 7720P PROGRAMMER PORT/ PANEL DOWNLOAD PORT TB 1 AC 1 AC 2 NOT USED or 12V DC IN SIGNAL STRENGTH (RSSI)/MODE...
Page 56
For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/MyWebTech/ WARRANTY For the latest warranty information, please go to: http://www.security.honeywell.com/hsc/resources/wa/ 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright 2010 Honeywell International Inc. www.honeywell.com/security Ê800-06826V1]Š 800-06826V1 6/10 Rev. B...