Summary of Contents for Siemens SIMATIC Field PG P4
Page 1
SIMATIC Getting Familiarized with the SIMATIC Field PG P4 Configuring And Operating The Field PG P4 SIMATIC Field PG P4 SIMATIC Field PG P4 Expansions Manual Configuring the SIMATIC Field PG P4 Error Diagnostics Hardware Information Reinstallation of the Software...
Page 2
Trademarks SIMATIC, SIMATIC HMI and SIMATIC NET are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners.
Where is this Manual Valid? This manual is valid for all supplied variations of the SIMATIC Field PG P4 and describes the state of delivery as of August 2004. Certifications, Standards and Approvals...
Page 4
This chapter also contains instructions for working with submodules and memory cards for programmable logic controllers and additional interfaces. Expansion Chapter 4 describes how to expand your SIMATIC Field PG P4 (for example, installation of memory expansions). Please observe the safety instructions in this section.
Page 5
Trainingscenter Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system. Please contact your regional training center or our central training center in D 90327 Nuremberg, Germany for details.
Page 6
Fax: +49 (180) 5050-223 E-Mail: simatic.hotline@ E-Mail: adsupport.asia@ E-Mail: adsupport@ sea.siemens.com siemens.com siemens.com GMT: +8:00 GMT: +1:00 GMT: –5:00 The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 7
• A forum, where users and experts from all over the world exchange their experiences. • Your local representative for Automation & Drives via our representatives database. • Information on field service, repairs, spare parts and more under “Services”. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 8
Preface SIMATIC Field PG P4 Manual viii A5E00180080-04...
• Always pull the power plug and disconnect the battery before connecting or disconnecting modules (containing ESDs). • Touch modules fitted with ESDs by their edges only. • Never touch wiring posts or printed conductors on modules (containg ESDs). SIMATIC Field PG P4 Manual A5E00180080-04...
Postfach 1963 D-92209 Amberg Tel.: 09621 80 3283 Fax: 09621 80 3278 Observing the Setup Guidelines The setup guidelines and notes on safety given in the manual must be observed on startup and during operation. SIMATIC Field PG P4 Manual A5E00180080-04...
Security One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) to the UL 60950 standard, 3rd Edition. Canadian Standard Association (CSA) to Standard C22.2. No. 60950 SIMATIC Field PG P4 Manual A5E00180080-04...
Page 16
This Class B digital apparatus complies with Canadian ICES-003. Avis Canadien Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Australia AS/NZS 3548 This product meets the requirements of the Standard. SIMATIC Field PG P4 Manual A5E00180080-04...
• Pack the Field PG and all accessories into the supplied rucksack case if you are going to transport it over greater distances. You should use the original package for the shipment of the programming device. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 18
Important Notes SIMATIC Field PG P4 Manual A5E00180080-04...
This chapter briefly presents the most important components of the SIMATIC Field PG P4. Get familiarized with these elements before you start to commission the PG. Chapter Overview Section Description Page Components of the SIMATIC Field PG P4 Keyboard Touchpad 2-13 LED displays 2-14 On/Off Pushbutton (Power Button)
Getting Familiarized with the SIMATIC Field PG P4 Components of the SIMATIC Field PG P4 View with closed display 1 System LEDs The system LEDs (battery status , device , drives , MPI/DP MPI/DP and Memory Card ) indicate the status of the battery, unit, drives, MPI/DP and Memory Card interface.
Getting Familiarized with the SIMATIC Field PG P4 Front view with open display 1 Display The Field PG P4’S 14.1” TFT display has a resolution of 1024 x 768 pixels (XGA) or 1400 x 1050 pixels (SXGA+) with up to 256k colors.
Page 22
Getting Familiarized with the SIMATIC Field PG P4 5 Touchpad The Touchpad has a pressure sensitive surface for precise mouse pointer positioning. 6 On/Off button (Power Button) Use the On/Off pushbutton to switch on the Field PG P4 (into active state) or to switch it from active to inactive state (Off, Standby or Hibernate).
Page 23
4 MPI/DP Multipoint Interface The MPI/DP interface is isolated from line potential. You can use it to connect the SIMATIC Field PG P4 to an S7 automation system or to a PROFIBUS network. 5 VGA Here you can connect an appropriate external monitor.
Getting Familiarized with the SIMATIC Field PG P4 View of the right side 1 Optical drive Depending on the device configuration, it can come with a DVD-ROM/CD-RW or a RW drive. For example, you can read the electronic manual of the supplied ”Backup PG”...
Page 25
Getting Familiarized with the SIMATIC Field PG P4 View of the left side 1 Opening for the Kensington lock Opening for the connection of a security cable. You can protect your PG against theft by locking the cable to a writing desk or any other heavy appliance.
Page 26
Getting Familiarized with the SIMATIC Field PG P4 Bottom view 1 Rechargeable battery The supplied rechargeable battery is installed behind a cover. The rechargeable battery (Lithium-Ion) makes the device portable, independent of an external power supply. The battery pack also prevents data loss in case of power failure. Use the recharchable battery supplied with the device only.
Page 27
Getting Familiarized with the SIMATIC Field PG P4 Keyboard Keyboard Layout The keyboard is split into the following areas: • Alphanumeric or typewriter keyboard with special keys • Function keys • Cursor control keys. Repeat Function All the keys on the keyboard are of the autorepeat type. The character is repeated as long as the key is pressed.
Getting Familiarized with the SIMATIC Field PG P4 Special Keys The special keys in the alphanumeric keyboard have the following functions: Function Backspace key This key moves the cursor one space to the left and deletes the character at this position.
Getting Familiarized with the SIMATIC Field PG P4 Function ALT Key (combination key) This key is only used in combination with other keys. For example, you can enter the hexadecimal value of an ASCII character using this key and the numeric keypad for example, F + ALT + 132 corresponds to “ä...
Page 30
Getting Familiarized with the SIMATIC Field PG P4 Numeric Keypad with Fn Key By pressing F and one of these keys, the numbers and characters can be used provided Num Lock is switched on. & / :Ö > : / –...
Getting Familiarized with the SIMATIC Field PG P4 Touchpad Definition The Touchpad is an input device for cursor control and menu operation (with mouse operation) in numerous programs. You can move the cursor to any screen position by touch. A left button click on sets the mark. The right button assignment varies, depending on the user program.
Getting Familiarized with the SIMATIC Field PG P4 LED displays Keyboard LEDs LED displays for the Num-Lock, Shift-Lock and Scroll-Lock keys. They indicate the current status of the shift keys. Meaning of the keyboard LEDs Symbol Meaning green Num-Lockon Num-Lock off...
Getting Familiarized with the SIMATIC Field PG P4 On/Off Pushbutton (Power Button) Switching the Field PG P4 On Hold the On/Off button (Power Button) down for approx. 1 second to switch on the device. Switching the Field PG P4 Off...
Page 34
Getting Familiarized with the SIMATIC Field PG P4 Caution The Field PG P4 supports different operating modes, according to the settings in the Windows power options. The power options are preset at the factory in such a way that the device always switches to defined operating modes (On, Standby, Hibernate, Off).
Getting Familiarized with the SIMATIC Field PG P4 Drives 2.6.1 Floppy Disk Drive You can use 3.5 disks (with 1.44 Mbytes or 720 Kbytes of memory). Handling Diskettes Access to the floppy drive is displayed by the drive’s status indicator and on the status indicator for external devices at the front of the keyboard.
Getting Familiarized with the SIMATIC Field PG P4 2.6.3 Optical Drive Depending on the device configuration, it can come with a DVD-ROM/CD-RW or a RW drive. For example, you can read the electronic manual of the supplied Backup PG DVD with this drive.
Page 37
Getting Familiarized with the SIMATIC Field PG P4 Additional Software To be attain the full functionality of the DVD-ROM/CD-RW or DVD RW drive, additional software (DVD player or burner software) is necessary. You can find it on the CD included in the delivery of the device. To install the software place the CD in the drive and follow the instructions on the screen.
External Power Unit and Battery External Power Unit External power supply for the SIMATIC Field PG P4 for operation on 120 V or 230 V power supply networks. The voltage range is selected automatically. With line operation the integrated battery is charged at the same time. The connecting cable for the SIMATIC Field PG P4 is installed fixed on the external power supply.
Page 39
Getting Familiarized with the SIMATIC Field PG P4 Battery The supplied rechargeable battery is installed behind a cover. The rechargeable battery (Lithium-Ion) makes the device portable, independent of an external power supply. The battery pack also prevents data loss in case of power failure. Use the rechargeable battery supplied with the device only.
Page 40
Getting Familiarized with the SIMATIC Field PG P4 The rechargeable battery has a typical service life of 300 charging cycles, i.e. under normal conditions of use it can be charged and discharged within six months after you have purchased the PG. Capacity loss beyond this time is technology–related, and warranty is therefore excluded by all manufacturers of...
What Does This Chapter Contain? The chapter below describes all tasks required to successfully set up your workplace. These include: • initial steps for commissioning your SIMATIC Field PG P4, • working with battery operation and replacing the battery, • connecting peripheral devices, •...
Configuring And Operating The SIMATIC Field PG P4 Unpacking and Setting Up the SIMATIC Field PG P4 Unpacking Your SIMATIC Field PG P4 Unpack your SIMATIC Field PG P4 as follows: 1. Remove the packing. 2. Do not throw the original packing away. Keep it if you need to transport the device at a later time.
Page 43
Setting up your SIMATIC Field PG P4 Find a comfortable and safe working position for your SIMATIC Field PG P4. 1. Put the SIMATIC Field PG P4 down on its base on an even surface at a comfortable working height and distance.
Fig. 3-2 Power supply connection Warning The SIMATIC Field PG P4 must only be operated with the provided power supply unit and/or battery pack. The external power supply must not be covered up (risk of over-heating). For reasons of safety you must use the patch cord and power supply that is included in the delivery.
Battery Operation Battery Operation If not connected to an external power supply unit, the SIMATIC Field PG P4 can be operated with the internal battery pack. 1. Switch on the device. Make sure the battery is sufficiently charged before you start work.
Page 46
Configuring And Operating The SIMATIC Field PG P4 Disposal of Used Batteries Lithium-Ion batteries can be recycled. Their components can be used as raw materials for new batteries or other products. Effective recycling of batteries is only possible when the used batteries are collected according to type.
Page 47
Configuring And Operating The SIMATIC Field PG P4 Performing a Calibration Cycle Broadly speaking, the procedure for a calibration cycle is as follows: 1. Before starting battery calibration, you have to select SIMATIC battery calibration under Control Panel > Power Options, than deactivate the options Activate battery alarm when power level reaches in the tab Alarms under Control Panel >...
3.4.1 Cold Start of the SIMATIC Field PG P4 When powering up the SIMATIC Field PG P4 for the first time the operating system is set up automatically (depending on the version delivered: Windows NT, Windows 2000 Professional or Windows XP Professional). Please proceed as follows: 1.
Page 49
Configuring And Operating The SIMATIC Field PG P4 Startup under Windows Once you have entered the requisite information and configured the operating system the PG is rebooted. The Welcome screen helps you to get familiar with the Desktop - user interface.
Configuring And Operating The SIMATIC Field PG P4 3.4.2 Restart of the SIMATIC Field PG P4 Once the Field PG P4 is configured, the user interface of the corresponding operating system is displayed following system startup every time you switch on or reset the PG.
Configuring And Operating The SIMATIC Field PG P4 Panel “Field PG” Panel “Field PG” helps you to work better with the Field PG P4. It has the following functions: • Automatic execution of battery calibration. • Setting the display brightness •...
Configuring And Operating The SIMATIC Field PG P4 Connecting Peripheral Devices Connect devices to the I Cable COM2/V.24 S5 Online AG (COM1/TTY) Fig. 3-3 Interface Cable Slots The I Cable enables the connection to S5 automation devices (COM1/TTY), to devices with a serial port (COM2/standard V.24) such as a modem or mouse and to devices with a parallel port (standard LPT) such as a printer or scanner.
Page 53
Connecting the Monitor To connect the monitor, proceed as follows: 1. Switch off the SIMATIC Field PG P4 and the monitor. 2. Open the port cover on the rear of the device. 3. Plug the monitor cable into the VGA socket connector.
Page 54
Configuring And Operating The SIMATIC Field PG P4 Caution Ensure that the used monitor is suitable for the set resolution and refresh rate. Connecting Devices to the USB Interface 2.0 You can connect USB devices (mouse, keyboard or printer) to the USB 2.0 interface connector.
Page 55
Configuring And Operating The SIMATIC Field PG P4 Connecting a Microphone The 3.5-mm phono jack can be used to connect microphones. Pin assignment: Mic- Power ground 3.5-mm microphone plug Fig. 3-7 Pin assignment of the microphone plug For microphone recordings, select all Programs > Accessories > Entertainment >...
Configuring And Operating The SIMATIC Field PG P4 Working with SIMATIC S5 Memory Submodules Editing SIMATIC S5 Memory Submodules You can read and program SIMATIC S5 memory submodules (EPROMs or EEPROMs) via the Memory Card interface. Use the S5 adapter for S5 memory submodules that is included in the scope of delivery for devices with Step 5 software.
Configuring And Operating The SIMATIC Field PG P4 Working with SIMATIC Memory Cards Working with SIMATIC Memory Cards SIMATIC memory cards can be read, programmed, and erased. SIMATIC memory cards are available for SIMATIC S5 and SIMATIC S7 software. SIMATIC Memory Card Fig.
Configuring And Operating The SIMATIC Field PG P4 Working with Micro Memory Cards Working with Micro Memory Cards Read, program and erase Micro Memory-Cards (MMC) via the Micro Memory Card interface. Operation with Micro Memory Cards is supported by STEP 7 V5.1 or higher.
The PC card interface supports two type II or one type III Cardbus card (32-bit) or PCMCIA card (16-bit). The SIMATIC Field PG P4 has two PC card ports. You can plug credit-card format communication modules for MODEM, FAX-MODEM, ISDN, Token Ring, ETHERNET, memory expansion and SCSI interface modules into these ports.
Configuring And Operating The SIMATIC Field PG P4 3.11 Connecting the Field PG P4 to a SIMATIC S5 Network Point-To-Point Connection In this section, you will learn how to connect your Field PG P4 to a programming device or S5 PLC using a point-to-point connection.
Configuring And Operating The SIMATIC Field PG P4 Caution The interface port may be damaged if you use the wrong patch cord. 3.12 Connecting the Field PG P4 to a SIMATIC S7 Network (MPI/DP) Connecting an S7 Programmable Controller via an MPI/DP Interface...
Page 62
Configuring And Operating The SIMATIC Field PG P4 3. Connect the cable to the MPI/DP interface. Caution Before plugging in the cables, the static charge on your body, the unit, and the cables must be equalized. You can do this by briefly touching the metal mounting plate for the interfaces on the rear panel.
Configuring And Operating The SIMATIC Field PG P4 3.13 Networking the Field PG P4 with Other Stations on PROFIBUS Networking the SIMATIC Field PG P4 on PROFIBUS PROFIBUS is an open and robust bus system for industrial use. It can be used to configure networks with up to 32 stations per segment.
Configuring And Operating The SIMATIC Field PG P4 3.14 Ethernet (RJ45 Ethernet Interface) Networking Field PG P4 via RJ45 Ethernet Interface The RJ45 Ethernet interface is a Twisted-Pair (TP) Interface for data transfer rates of 10/100 Mbaud. This on-board interface is compatible with Intel pro/100+ PCI Adapters.
SIMATIC Field PG P4 Expansions What Does This Chapter Contain? This chapter shows you how to expand your SIMATIC Field PG P4 with additional expansion memory submodules to increase its performance. Please note the included comments on safety. Chapter Overview...
512 Mbytes – 512 Mbytes – 768 Mbytes 1024 Mbytes – Notice Please only use Siemens memory modules as these are qualified and released for this device. Refer to the catalog for the ordering data. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 67
SIMATIC Field PG P4 Expansions Caution The electronic components of the printed circuit boards are highly sensitive to electrostatic discharge. Certain precautionary measures are therefore necessary when handling such components. These measures are explained in the guidelines for handling electrostatically-sensitive devices in Appendix A.
SIMATIC Field PG P4 Expansions Processor Upgrade You can boost the performance of your SIMATIC Field PG P4 with a processor upgrade. Consult your local dealer or service partner. Notice If an upgrade is implemented, for example to a processor with a different frequency, it may be important to also upgrade the BIOS.
Configuring the SIMATIC Field PG P4 What Does This Chapter Contain? In this chapter, you will learn how to configure your programming device. You need to do this if you change your system by adding, removing, or exchanging expansion modules and memory expansions, or by replacing a system module.
SETUP-Program The SETUP program is in the ROM-BIOS. Information about the system configuration is stored in the battery-buffered RAM of the SIMATIC Field PG P4. You can use SETUP to set the hardware configuration (for example, hard disk type) and define the system characteristics. You can also use SETUP to set the time of day and date.
Page 71
Configuring the SIMATIC Field PG P4 Screen Display Following Power On With the standard setting of your PG, the screen displays after power-on, for example: Phoenix NoteBIOS 4.0 Release 6.0 –A5E0001xxxx-ES00x Copyright 1985-2002 Phoenix Technologies Ltd. All Rights Reserved SIEMENS Field PG P4 Version Vxx.xx.xx...
Page 72
Configuring the SIMATIC Field PG P4 The following screen form appears when you start the BIOS setup: PhoenixBIOS Setup Utility Header Main Advanced Security Power Boot Version Exit Menu bar Item Specific Help System Time: [ 15:35:32 ] [ 02/06/2003 ] System Date: <Tab>,...
Configuring the SIMATIC Field PG P4 The Main Menu PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help System Time: [ 15:35:32 ] [ 02/06/2003 ] System Date: <Tab>, <Shift-Tab>, Diskette A: [1,44 MB 3 1/2”] <Enter>...
Page 74
Configuring the SIMATIC Field PG P4 System Time und System Date System Time and System Date indicate the current values. Once you have selected the appropriate option, you can use the [+] and [-] keys to modify the time setting...
Page 75
Configuring the SIMATIC Field PG P4 ”Type” Field The parameters you can select here are usually stored on the IDE drive. The ’Auto’ setting in the ’Type’ field means that these values are automatically read from the drive and written into memory .
Page 76
Configuring the SIMATIC Field PG P4 “Memory Cache” Field The following pop-up menu appears when you select the option “Memory cache” in the main menu: PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help System Time:...
Page 77
Configuring the SIMATIC Field PG P4 Option “Boot Options” The following submenu appears when you select the option “Boot Options” in the main menu: PhoenixBIOS Setup Utility Main Boot Options Item Specific Help QuickBoot Mode: [Enabled] Allows the system to skip certain tests while booting.
Page 78
Configuring the SIMATIC Field PG P4 Example of a Summary screen: PhoenixBIOS Setup Utility System ROM E7A6 – FFFF CPU Type Pentium(R) 4 M BIOS Date 06/02/03 CPU Speed 1.60GHz COM Ports 03F8 System Memory 640 KB LPT Ports Ext.Memory...
Page 79
Configuring the SIMATIC Field PG P4 Option “Keyboard Features” The following submenu appears when you select the “Keyboard Features” field in the main menu: PhoenixBIOS Setup Utility Main Keyboard Features Item Specific Help NumLock: Selects Power-On state Key Click: [Disabled]...
Page 80
Configuring the SIMATIC Field PG P4 “Hardware Options” Field The following submenu appears when you select the “Hardware Options” field in the main menu: PhoenixBIOS Setup Utility Main Hardware Options Item Specific Help Enable or disable the Enabled PCI – MPI / DP:...
Page 81
Configuring the SIMATIC Field PG P4 Entry Meaning Onboard Ethernet Enable the on-board Ethernet interface. Resources are managed by the BIOS PCI Plug & Play mechanism. [Disabled] Ethernet inactive. Ethernet interface hardware is switched off. The operating system can not operate the interface [Enabled] Ethernet active.
Configuring the SIMATIC Field PG P4 The Advanced Menu Menu Structure PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help Installed O/S: WinXP/2000 [ No ] Reset Configuration Data: Select the operating system installed Serial port A:...
Page 83
Configuring the SIMATIC Field PG P4 S5 TTY port Configure the TTY port with the options: [Disabled] No configuaration [Enabled] User configuration [Auto] BIOS or OS chooses confuguration. Local Bus IDE adapter [Disabled] No local IDE adapter. [Primary] One IDE adapter for max. two drives.
Configuring the SIMATIC Field PG P4 The Security Menu You can only edit the fields enclosed in square brackets. Two passwords are assigned to protect your programming device from unauthorized use. You can use the supervisor password to prevent use of diskettes for the normal user and to limit use of the hard disk.
Configuring the SIMATIC Field PG P4 The Power Menu This menu has the following structure: PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help [Disabled] Power Savings: [Enabled] [Disabled] Hard Disk Timeout: [Disabled] Switch on/off Power...
Page 86
Configuring the SIMATIC Field PG P4 After Power Failure [Stay Off] After power failure the device is not switched on automatically. [Last State] Provided it was switched on prior to a power failure, the device is switched on again [Power On] Restores the previous power state before loss occured.
Configuring the SIMATIC Field PG P4 The Boot Menu This menu allows you to set the priority of boot devices. PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help +Removable Devices +Hard Drive Keys used to view or...
Page 88
Configuring the SIMATIC Field PG P4 Groups marked + can contain more than one device. When you select a group marked in this way, hit Enter to view the list of devices in the group. See the figure below for an illustration:...
Configuring the SIMATIC Field PG P4 The Version Menu This menu contains the information you will have to quote when you send us technical questions about your system. PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help...
Configuring the SIMATIC Field PG P4 The Exit Menu The setup program is always terminated using this menu. PhoenixBIOS Setup Utility Main Advanced Security Power Boot Version Exit Item Specific Help Save Changes & Exit Exit Without Saving Changes Exit System Setup and...
Every time a key is pressed, a beep is heard and no characters are displayed • • <CTRL> <PAUSE> Keyboard buffer overflow < \ > key does not exist • • Wrong keyboard driver German keyboard: <ALTGr> <ß> • International keyboard : <\> key SIMATIC Field PG P4 Manual A5E00180080-04...
Page 92
Error Diagnostics SIMATIC Field PG P4 Manual A5E00180080-04...
Windows NT 4.0 Start > Programs > Administrative Tools (Common)> Windows NT Diagnostics Windows 2000/XP Start > Run enter msinfo32 in the field Open and confirm with OK SIMATIC Field PG P4 Manual A5E00180080-04...
Both interfaces are conceived for high-current USB 2.0 (500mA). However, they cannot be used simultaneously as high-current interface. Pin-No. Designation Description Input / Output +5V (fused) Output - Data Data line Input / Output + Data Data line Input / Output Ground SIMATIC Field PG P4 Manual A5E00180080-04...
Page 97
Unassigned LTG_A Signal line A of the MPI module Input/output RTS_PG RTS output signal of the MPI module. The Output control signal is “1” when the programming device is sending. Screen on connector casing SIMATIC Field PG P4 Manual A5E00180080-04...
Page 98
Input Internal 75 Ω output 4, 5 * SYMR Received data Input Internal 75 Ω output 7, 8 * SYMT Shield LED yellow Connection LED green Activity * is not necessary for data transfer SIMATIC Field PG P4 Manual A5E00180080-04...
Page 99
Hardware Information Micro-In Plug for external microphone. Pinout: Mic- Power ground 3.5-mm Microphone phono plug Fig. 7-2 Microphone Headphone Plug for external headphones. Pinout: Left Ritht 3.5-mm Stereo phono plug Fig. 7-3 Headphone SIMATIC Field PG P4 Manual A5E00180080-04...
Page 100
Data line 5 Output (TTL levell) Data - Bit 6 (LPT) Data line 6 Output (TTL levell) Data - Bit 7 (LPT) Data line 7 Output (TTL levell) /ACK (LPT) Acknoledge Input (4,7 kW pull up) SIMATIC Field PG P4 Manual A5E00180080-04...
Page 102
Description Input /Output Data carrier detect Input Receive data Input Transmit data Output Data terminal ready Output Ground Data set ready Input Request to send Output Clear to send Input Incoming call Input SIMATIC Field PG P4 Manual 7-10 A5E00180080-04...
Patch Cords SIMATIC S5 Patch Cord You can use the SIMATIC S5 cord set (not included in all delivered versions) to connect your SIMATIC Field PG P4 to a SIMATIC S5 PLC. Please not the comments in Chapter 3. Patch cord...
Restoring the Hard Disk (Data Deleted) Installing Drivers and Software Installing the Recovery CD for Microsoft Windows NT Installing the Recovery CD for Microsoft Windows 2000 Installing the Recovery CD for Microsoft Windows XP 8-10 Installing the SIMATIC-Software 8-12 SIMATIC Field PG P4 Manual A5E00180080-04...
• Click Start on the Windows task bar and • Select Simatic > License Management > Automation License Manager to open the Automation License Manager which will help you to save all authorizations or License Keys on your License Key Disk. SIMATIC Field PG P4 Manual A5E00180080-04...
All the existing data, programs, user settings and authorizations or License Keys on the drives will be deleted in the process and will thus be lost. You will find the description of the functions in the README.TXT file on the Restore CD. SIMATIC Field PG P4 Manual A5E00180080-04...
Use the Recovery CD to boot as described in steps 1 to 3 above and then format drive C: with the program “Format”. Type: ”A:\>Format C:”. The creation of NTFS partitions is done under the Windows NT setup program. Starting the Windows NT setup is described in chapter 8.4. SIMATIC Field PG P4 Manual A5E00180080-04...
7. To format the partition from the Recovery CD, as described above in steps 1 to 3, reboot and then format drive C: with the “Format” program. Enter: ”A:\>Format C:” (A: is the CD-ROM drive). SIMATIC Field PG P4 Manual A5E00180080-04...
Press <F2> to enter Setup is displayed. On the completion of initialization, a ”Boot Menu” appears. 3. Select the ”CD-ROM Drive” with the cursor. 4. When “Microsoft Windows 98-Startup Menu” is displayed, select “1. Boot for CD-Recovery”. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 111
Reinstallation of the Software 5. You have to acknowledge the “SIEMENS End User License Agreement” with the F8 function key. Pressing ESC allows you to decline the agreement and cancels the installation. 6. In the next screens you can select the components which are to be copied from the CD to the hard disk.
If the hard disk has not been installed, first select “2. Boot for FDISK, FORMAT or Windows-Setup (Section 8.2.3). 5. You have to confirm the “SIEMENS End User License Agreement” with the F8 function key. Pressing ESC allows you to decline the agreement and cancels the installation.
Page 113
You can set another language and keyboard via the control panel with the dialog Start >Settings > Control Panel > Regional Options > tab ”General”, box ”Menus and dialogs”> tab ”Input locales”, box ”Input language”. SIMATIC Field PG P4 Manual A5E00180080-04...
The new installation or reinstallation of the operating system is accomplished with the Recovery CD. This CD contains encoded files which can only be transferred to a SIEMENS SIMATIC programming device. Data transfer is made with the OEMSETUP.EXE program on the CD ROM, or after booting from the CD ROM with the recovery function.
Page 115
If the hard disk has not been installed, first select “2. Boot for FDISK, FORMAT or Windows-Setup (Section 8.2.3). 5. You have to acknowledge the “SIEMENS End User License Agreement” with the F8 function key. Pressing ESC allows you to decline the agreement and cancels the installation.
SIMATIC software is only delivered with versions containing the corresponding SIMATIC software. The installation of the authorizations or the activation of the License Keys is described in Section 3.4.1 “Cold Start of the Field PG P4”. SIMATIC Field PG P4 Manual 8-12 A5E00180080-04...
Page 117
Guidelines for Handling Electrostatically-Sensitive Devices (ESD) Chapter Overview Section Description Page What is ESD? Electrostatic Charging of Persons General Protective Measures Against Electrostatic Discharge Damage SIMATIC Field PG P4 Manual A5E00180080-04...
In most cases, the damage caused by an overvoltage is not immediately noticeable and results in total damage only after a prolonged period of operation. SIMATIC Field PG P4 Manual A5E00180080-04...
Antistatic material, for example, wood or concrete 5 10 20 30 40 50 60 70 80 90 100 Relative air humidity in % Fig. A-1 Electrostatic Voltages which can Build up on a Person SIMATIC Field PG P4 Manual A5E00180080-04...
If you have to carry out measurements on a module, you must discharge your body’s electrostatic charge before you start the measurement by touching grounded metallic parts. Use grounded measuring devices only. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 121
Technical Specifications Note At the start of the PG the BIOS messages (Summary Screen) offer a precise overview of your SIMATIC Field PG P4 configuration SIMATIC Field PG P4 Manual A5E00180080-04...
Page 122
10 V/m with 80% amplitude modulation at 1 kHz, 80 kHz - 1GHz (to IEC 61000-4-3) 10 V/m, pulse modulated 50% duty cycle, 900MHz and 1,89 GHz (to IEC 61000-4-3) Magnetic field 30 A/m, 50Hz (to IEC 61000-4-8) SIMATIC Field PG P4 Manual A5E00180080-04...
Page 123
CRT only: 1280 x 1024 at 100 Hz / 32 Bit colors * ) The burning operation with the DVD-ROM/CD-RW or DVD+R/+RW drive is only permissible in an untroubled environment and under an ambient temperature not exceeding 35_C. SIMATIC Field PG P4 Manual A5E00180080-04...
Page 124
DP12 patch cord Physical interface RS485, galvanically isolated Memory address area 0CC00h...0CC7FFh or 0DC00h...0DC7FFh 5, 10, 11 or 15 configurable per software USB 2.0 2 USB ports 1 x high-current max. (500mA), 1x low–current (100mA) SIMATIC Field PG P4 Manual A5E00180080-04...
Page 125
3.5 mm phone jack respectively Function displays Status LEDs Caps Lock Scroll Lock Num Lock Battery status Device status Access to FD / HD / CR–ROM S5 Module/Memory Card active MPI/DP token passing SIMATIC Field PG P4 Manual A5E00180080-04...
Page 126
Technical Specifications SIMATIC Field PG P4 Manual A5E00180080-04...
What does This Chapter Contain? This chapter contains a glossary in which you will find a list of the terminology used in conjunction with the Siemens range of programming devices and a brief explanation of each of the terms. SIMATIC Field PG P4 Manual...
Page 128
The base memory is a part of the main memory. It is 640 Kbytes for all programming devices. The size is entered in the SETUP menu under the entry “System Memory” and is not changed even if the memory is extended. SIMATIC Field PG P4 Manual Glossary-2 A5E00180080-04...
Page 129
Compact Disc Read Only Memory. Removable memory for large amounts of data. Click Pressing and immediately releasing the left mouse button; selects objects or triggers commands. COM2 Port Serial RS-232 interface which can be used to connect a mouse or a printer. SIMATIC Field PG P4 Manual Glossary-3 A5E00180080-04...
Page 130
If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. SIMATIC Field PG P4 Manual Glossary-4 A5E00180080-04...
Page 131
EPROM/EEPROM Submodules These are plug-in submodules with EPROM/EEPROM chips. S5 user programs can be stored on them. These programmed submodules are then plugged into specially designed slots in the programmable logic controller. SIMATIC Field PG P4 Manual Glossary-5 A5E00180080-04...
Page 132
Function Keys Function keys can be divided into two different types; the normal function keys which are assigned a particular function of the computer (for example, delete key), and programmable function keys (softkeys). SIMATIC Field PG P4 Manual Glossary-6 A5E00180080-04...
Page 133
• An interface is the connection between individual hardware elements such as PLCs, programming devices, printers, or monitors via physical connections (cables). • An interface is also the connection between different programs, to enable them to work together. SIMATIC Field PG P4 Manual Glossary-7 A5E00180080-04...
Page 134
Light Emitting Diode (for example, status display). Semiconductor diode that transforms electrical energy into light. License Key The license key is the electronic key for a license. Siemens AG issues license keys for software that is legally protected by license. LPT1 Port The LPT1 port (Centronics port) is a parallel interface that can be used to connect a printer.
Page 135
The other mouse keys may have different assignments according to the application. With the mouse, objects can be selected, menus processed, and functions started. SIMATIC Field PG P4 Manual Glossary-9 A5E00180080-04...
Page 136
Information is transmitted byte for byte via a parallel interface (port). This means that the transmission rate is very fast. The programming devices have one parallel interface (LPT1). Password Unique sequence of characters that is entered for user identification. See Access Protection. SIMATIC Field PG P4 Manual Glossary-10 A5E00180080-04...
Page 137
Used to connect a programming device. Some CPUs are optionally equipped with two PG links. Pixel Pix Element (picture point). The pixel represents the smallest element that can be reproduced on-screen or on a printer. SIMATIC S5 programmable logic controller SIMATIC Field PG P4 Manual Glossary-11 A5E00180080-04...
Page 138
Contains the DOS tools for setting up harddisks and the Windows operating system. Restart Warm start of a computer in operate state without switching off the power supply (Ctrl + Alt + Del). SIMATIC Field PG P4 Manual Glossary-12 A5E00180080-04...
Page 139
SETUP if a memory extension, new modules, or a new drive are added to the hardware configuration. SIMATIC S5 Memory Submodules Memory submodules for SIMATIC S5 which are programmed with the PG and can be plugged into an S5 programmable logic controller. SIMATIC Field PG P4 Manual Glossary-13 A5E00180080-04...
Page 140
Transition to power-off status, with prior saving of the system contents to the hard disk drive. Suspend to RAM Transition to power-saving status, with prior saving of the system contents to the RAM. SIMATIC Field PG P4 Manual Glossary-14 A5E00180080-04...
Page 141
It is assigned to a programmable module (for example, CPU, FM) and can be split into smaller blocks (modules). Video Graphics Array. Industrial standard graphics adapter for use with any commonly used software. SIMATIC Field PG P4 Manual Glossary-15 A5E00180080-04...
Page 142
• Write protection for files; this type of write protection is stored in the computer and is allocated by the system manager. • Floppy disk write protection; for 3 1/2 in. diskettes by opening the write protection hole. SIMATIC Field PG P4 Manual Glossary-16 A5E00180080-04...