Honeywell Fire-lite ROME Series Product Installation Document
Honeywell Fire-lite ROME Series Product Installation Document

Honeywell Fire-lite ROME Series Product Installation Document

Relay option module enclosure

Advertisement

Quick Links

The ROME (Relay Option Module Enclosure, red) and ROME-B (black) is shipped with one ANN-BUS Relay Module
already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi-
Module.
Relay Module
The Relay Module provides 10 programmable Form-C relays when used with a compatible FACP (Fire Alarm Control
Panel). This document is provided as a quick reference. For more detailed programming information, refer to the appro-
priate FACP installation manual.
Relay Module Specifications
Relay Designations and Terminals
The relay numbers and terminal designations are illustrated in the following illustration.
Relay Module
Operating Voltage
Max. Current @
Alarm
24 VDC
Standby
Operating Temperature
Max. Wiring Distance from FACP
(with 12 AWG wire)
Relay Contact Ratings
Indoor Use in Dry Location Only
R9
R10
R7
R8
R5
R6
R3
R4
R1
R2
ROME Series
Relay Option Module Enclosure
Product Installation Document
PN 53530:B 9/14/2009 09-327
24 VDC
75 mA
15 mA
32° to 120° F
(0° to 49° C)
1,250 ft. (380 m)
2 amps @ 30 VDC
(resistive)
0.5 amps @ 30 VAC
(resistive)
Relay Module
NO
NC
C
NO
NC
C
Normally Open,
Normally Closed
and Common
terminals for each
relay follow the
same pattern as
illustrated above.

Advertisement

loading

Summary of Contents for Honeywell Fire-lite ROME Series

  • Page 1 ROME Series Relay Option Module Enclosure Product Installation Document PN 53530:B 9/14/2009 09-327 The ROME (Relay Option Module Enclosure, red) and ROME-B (black) is shipped with one ANN-BUS Relay Module already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- Module.
  • Page 2 Wiring the Relay Module to an FACP Refer to the following table and illustration for wiring connections. All connections/sources are to be power-limited and Relay Terminals (TB1) FACP ANN-BUS Terminals supervised. 12 - 18 AWG (0.75 - 3.25 mm ) wire for 24 VDC circuit is Terminal 1 (B) B (ANN-BUS) acceptable.
  • Page 3 Mounting an Optional Second Relay Module in the ROME Series ANN-MBRLY Mounting Bracket Installation An optional second Relay Module can be mounted inside the ROME Series using the ANN-MBRLY mounting bracket. Two holes must be drilled in the enclosure to secure the ANN-MBRLY as described in the following steps: Place the ANN-MBRLY mounting bracket flat against the inside back wall of the ROME Series, while positioning two oblong holes over the mounting studs as shown in the following illustration.
  • Page 4 Relay Module Installation on ANN-MBRLY Mounting Bracket Hold the Relay Module with the relays positioned to the left and install the Relay Module on the ANN-MBRLY mounting bracket by positioning the four module mounting holes over the four standoffs on the mounting bracket. Secure the Relay Module to the ANN-MBRLY mounting bracket with the four supplied screws.
  • Page 5 Mounting an Addressable Multi-Module in the ROME Series MULTIMOD-BRKT Mounting Bracket Installation An addressable Multi-Module communicates with the FACP via the SLC loop. A Multi-Module can be installed inside the ROME Series enclosure using the MULTIMOD-BRKT module mounting bracket. Install the MULTIMOD-BRKT as described below.
  • Page 6 Install the supplied module insulating pad on the MULTIMOD-BRKT bracket by aligning the four outer holes with the four standoffs on the bracket and pressing the pad onto the standoffs and flat against the bracket as illustrated below. standoff standoff standoff standoff Install the addressable Multi-Module on the MULTIMOD-BRKT mounting bracket by positioning the four module...

This manual is also suitable for:

Fire-lite rome-bFire-lite rome