Technical data
8.3 Ambient conditions
8.3
Ambient conditions
Climatic conditions
Temperature
- During operation
- During storage/shipping
- Gradient
Relative humidity
- During operation
- During storage/shipping
Air pressure
- During operation
- During storage/shipping
For P320-4 S you must set "Turbo Mode Level" to "Temperature optimized" in the "Power" menu,
1
selection "Advanced CPU Control", of the BIOS Setup; otherwise you have to reduce the maximum
ambient temperature by 5 °C.
RAL = Restricted Access Location
2
Installation of device in operating facilities with restricted access, for example, a locked control cabinet.
90
Tested according to IEC 60068-2-1, IEC 60068-2-2, IEC 60068‑2‑14
Standard rail mounting (preferred mounting position):
Operation with CFast card and/or SSD:
● With max. 1 expansion card
(max. load 10 W): 0 to +40° C
● With max. 1 expansion card
(max. load 10 W) in RAL
Operation with CFast card:
● Without expansion cards in RAL
Vertical mounting:
Operation with CFast card and/or SSD:
● Without expansion cards: 0 to +40° C
Operation with SSD:
● With max. 1 expansion card
(max. load 10 W) in RAL
Operation with CFast card:
● Without expansion cards
in RAL
: 0 to +50° C
2
1
● With max. 1 expansion card
(max. load 10 W): 0 to +40° C
● With max. 1 expansion card
(max. load 10 W) in RAL
-40 °C to +70 °C (for devices with CFast or SSD)
Operating mode: Max. 10° C/h; Storage: 20° C/h; no condensation
Tested according to IEC 60068-2-78, IEC 60068-2-30
5% to 80% at 25° C (no condensation)
5% to 95% at 25° C (no condensation)
1080 to 795 hPa
(corresponds to an altitude of -1000 m to 2000 m)
1080 to 660 hPa
(corresponds to an altitude of -1000 m to 3500 m)
: 0 to +50° C
2
1
: 0 to +55° C
2
1
: 0 to +45° C
2
1
: 0 to +50° C
2
1
SIMOTION P320-4 E / P320-4 S
Manual, 01/2015