  • Page 3 ___________________ Line reactors Safety information ___________________ General ___________________ Mechanical installation SINAMICS ___________________ Electrical installation SINAMICS G130 ___________________ Line reactors Technical specifications Operating Instructions Control version V4.7 04/2014 A5E00331462A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information ........................... 7 General safety instructions ......................7 General ..............................11 Mechanical installation .......................... 15 Electrical installation..........................19 Technical specifications ........................21 Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 6 Table of contents Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 7: Safety Information

    Safety information General safety instructions DANGER Danger to life due to live parts and other energy sources Death or serious injury can result when live parts are touched. • Only work on electrical equipment if you are appropriately qualified. • Always observe the country-specific safety rules for all work. Generally, six steps apply when establishing safety: 1.
  • Page 8 Safety information 1.1 General safety instructions WARNING Danger to life when live parts are touched on damaged devices Improper handling of devices can cause damage. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. •...
  • Page 9 Safety information 1.1 General safety instructions WARNING Danger to life through unexpected movement of machines when using mobile wireless devices or mobile phones Using mobile radios or mobile phones with a transmit power > 1 W closer than approx. 2 m to the components may cause the devices to malfunction, influence the functional safety of machines therefore putting people at risk or cause material damage.
  • Page 10 Safety information 1.1 General safety instructions NOTICE Device damage caused by incorrect voltage/insulation tests Incorrect voltage/insulation tests can damage the device. • Before carrying out a voltage/insulation check of the system/machine, disconnect the devices as all converters and motors have been subject to a high-voltage test by the manufacturer, and therefore it is not necessary to perform an additional test within the system/machine.
  • Page 11: General

    General Description Line reactors limit low-frequency line-side harmonics to permissible values. WARNING Danger to life if the fundamental safety instructions and remaining risks are not carefully observed The non-observance of the fundamental safety instructions and residual risks stated in Chapter 1 can result in accidents with severe injuries or death. •...
  • Page 12 General Note Length of connection cables The connection cables between line reactor and Line Module, as well as between line reactor and line filter, must be kept as short as possible (max. 5 m). You must use shielded connection cables, whose cable shields are attached at both ends. Shielding can only be omitted if the following conditions are met: •...
  • Page 13 General Power Module Unit rating of the Power Module Suitable line reactor Line voltage 3-phase 660 – 690 VAC 6SL3310-1GH28-5AAx 85 kW 6SL3000-0CH31-1AA0 6SL3310-1GH31-0AAx 90 kW 6SL3000-0CH31-1AA0 6SL3310-1GH31-2AAx 110 kW 6SL3000-0CH31-6AA0 6SL3310-1GH31-5AAx 132 kW 6SL3000-0CH31-6AA0 6SL3310-1GH31-8AAx 160 kW 6SL3000-0CH32-2AA0 6SL3310-1GH32-2AAx 200 kW 6SL3000-0CH32-2AA0 6SL3310-1GH32-6AAx...
  • Page 14 General Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 15: Mechanical Installation

    Mechanical installation Dimension drawing Figure 3-1 Dimension drawing of line reactor Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 16 Mechanical installation Table 3- 1 Dimensions of line reactor, 380 V – 480 V 3 AC (all values in mm) 6SL3000- 0CE32-3AA0 0CE35-1AA0 0CE38-7AA0 0CE41-0AA0 0CE32-8AA0 0CE36-3AA0 0CE33-3AA0 0CE37-7AA0 12.5 212.5 211.5 211.5 84.5 Lengths n1 and n2 correspond to the drill hole spacing Table 3- 2 Dimensions of line reactor, 500 V –...
  • Page 17 Mechanical installation Table 3- 3 Dimensions of line reactor, 660 V – 690 V 3 AC (all values in mm) 6SL3000- 0CH31-1AA0 0CH34-8AA0 0CH38-4AA0 0CH31-6AA0 0CH36-0AA0 0CH32-2AA0 0CH32-7AA0 0CH33-4AA0 12.5 232.5 84.5 56.5 Lengths n1 and n2 correspond to the drill hole spacing Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 18 Mechanical installation Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 19: Electrical Installation

    Electrical installation Connection When connecting the line filter and line reactor, you must take into account the following conditions to ensure that they function correctly: ● Use shielded control cables. The shield must be connected at both ends. ● With analog control cables, connecting the shield at both ends can result in coupled-in noise.
  • Page 20 Electrical installation Line reactors Operating Instructions, 04/2014, A5E00331462A...
  • Page 21: Technical Specifications

    Technical specifications General technical data Table 5- 1 General technical data Line frequency 47 to 63 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation Ambient temperature -25 to +70 °C -25 to +70 °C 0 to +50 °C 95 % Relative air humidity 5 to...
  • Page 22 Technical specifications Detailed technical data Table 5- 2 Technical data of line reactors, 380 V – 480 V 3 AC, part 1 Order number 6SL3000- 0CE32-3AA0 0CE32-8AA0 0CE33-3AA0 0CE35-1AA0 Suitable for Power Module 6SL3310- 1GE32-1AAx 1GE32-6AAx 1GE33-1AAx 1GE33-8AAx Type rating of the Power Module kW Rated voltage 3 AC 380 –10% to 3 AC 480 +10% (-15% <...
  • Page 23 Technical specifications Table 5- 4 Technical data of line reactors, 380 V – 480 V 3 AC, part 3 Order number 6SL3000- 0CE41-0AA0 Suitable for Power Module 6SL3310- 1GE41-0AAx Type rating of the Power Module kW Rated voltage 3 AC 380 –10% to 3 AC 480 +10% (-15% < 1 min) 1022 thmax Power loss...
  • Page 24 Technical specifications Table 5- 6 Technical data of line reactors, 500 V – 600 V 3 AC, part 2 Order number 6SL3000- 0CH34-8AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 Suitable for Power Module 6SL3310- 1GF34-1AAx 1GF34-7AAx 1GF35-8AAx 1GF37-4AAx Type rating of the Power Module kW Rated voltage 3 AC 500 –10% to 3 AC 600 +10% (-15% <...
  • Page 25 Technical specifications Table 5- 8 Technical data of line reactors, 660 V – 690 V 3 AC, part 1 Order number 6SL3000- 0CH31-1AA0 0CH31-1AA0 0CH31-6AA0 0CH31-6AA0 Suitable for Power Module 6SL3310- 1GH28-5AAx 1GH31-0AAx 1GH31-2AAx 1GH31-5AAx Type rating of the Power Module kW Rated voltage 3 AC 660 –10% to 3 AC 690 +10% (-15% <...
  • Page 26 Technical specifications Table 5- 10 Technical data of line reactors, 660 V – 690 V 3 AC, part 3 Order number 6SL3000- 0CH34-8AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 Suitable for Power Module 6SL3310- 1GH34-1AAx 1GH34-7AAx 1GH35-8AAx 1GH37-4AAx Type rating of the Power Module kW Rated voltage 3 AC 660 –10% to 3 AC 690 +10% (-15% <...