Displaying the Backplane and Serial Number Information

Displaying the Backplane and Serial Number Information

You can display the backplane information, including the serial number for the switch by using the show
sprom backplane command.

Displaying Environmental Information for the Switch

You can display all the environment-related switch information by using the show environment command.

Displaying the Current State of a Module

You can display information about modules that are installed in the switch chassis by using the show module
command. This information includes module type, bootup status, MAC addresses, serial numbers, software
versions, and hardware versions. You can use this command in the following ways to display information
about all the installed modules or a specific module:
• For information on all modules, use the show module command.
• For information on a specific supervisor, system controller, line card, or fabric module, use the show
Note
This command reports on only software-controlled modules, such as supervisors, system controllers, line
cards, fabric modules, fan trays, and power supplies. It doesn't report on modules that are not software
controlled, such as blank modules installed in empty slots to control airflow.
This table provides descriptions of the module status that is displayed with the show module commands.
Line Card State
powered up
testing
initializing
failure
ok
Cisco Nexus 9516 NX-OS Mode Switch Hardware Installation Guide
44
module slot_number command to specify a slot number.
Note
To determine the slots to specify, use the show inventory command.
Description
The hardware has electrical power. When the hardware is powered up, the software
begins booting.
The module has established connection with the supervisor and the module is
performing bootup diagnostics.
The diagnostics have completed successfully and the configuration is being downloaded.
The switch detects a module failure upon initialization and automatically attempts to
power-cycle the module three times. After the third attempt, the module powers down.
The switch is ready to be configured.