SIGNAL PROCESSING UNIT PFV-SP3100 BACKUP POWER SUPPLY UNIT HK-PSU01 INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher (PFV-SP3100) Serial No. 10001 and Higher (HK-PSU01)
Page 2
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
The functions and specifications of HK-PSU01 and PFV-SP3100’s power supply unit are equal. This manual uses “Power Supply Unit” for HK-PSU01 and PFV- SP3100’s power supply unit. The following manuals are prepared for PFV-SP3100.
2 Power cord, 250 V 10 A (2.5 m) : ! 1-782-929-11 For the customers outside of the area as shown above, please contact your local Sony Sales Office/Service Center. . Use a specified power cord only. Be sure to use a recommended power cord to avoid fire and/or an electric shock.
1-3. Installation Space 1-3. Installation Space . Do not block the ventilation holes of the unit. . Both of the front and rear sides must be at least 20 cm away from the walls for ventilation and mainte- nance. The outer dimensions of PFV-SP3100 are as shown here: 43.6 1-2 (E) Unit: mm...
1-4. Installing/Removing Optional Power Supply Unit Before installing the backup power supply unit HK-PSU01 in PFV-SP3100, set the power switch of HK-PSU01 to the “O” position (OFF). Otherwise, deterioration of a connector which connects HK-PSU01 to PFV-SP3100 may cause a fire.
1-5. Installing Optional Board 1-5. Installing Optional Board The optional board can be installed in any empty slot of PFV-SP3100. When installing the processing module controller, the No.4 slot is used as the master slot and the No.3 slot is used as the sub-slot.
Page 9
6. Reinstall the board retainer. 7. Reinstall the front panel. When removing the main board, turn the board lever in the direction of the arrow 2 , and pull out the board toward you. Main board Board lever PFV-SP3100 1-5. Installing Optional Board Installing Connector Panel (Rear side) The connector panel must be installed to the slot which contains the main board.
1-6. Rack Mounting 1-6. Rack Mounting PFV-SP3100 can be mounted on a 19-inch standard rack for use. Mount PFV-SP3100 on the rack properly in the procedure below using a specified rack mounting kit. Specified rack mounting kit: RMM-10 PFV-SP3100 may not be able to be mounted on a 19-inch standard rack using a rack mounting kit other than the specified one.
Page 11
The maximum depth of an adaptor is 750 mm. The minimum depth of an adaptor is 595 mm. 3. Firmly lay the right and left adaptors in the rack with the specified six screws. (Following figure is case of left side.) RMM-10 Front B 4x10...
Warning status output of board installed in the No.2 slot Warning status output of board installed in the No.3 slot Warning status output of board installed in the No.4 slot Sony Part Number 1-569-370-12 – – Description The output of power unit A is abnormal.
2-1. Cleaning the Filter Be sure to turn off the power switch and disconnect the power cord from the outlet before starting any work. . The temperature inside the unit increases if dust adheres to the filter and the ventilation holes are blocked. Touching inside the unit while it is hot may result in burn injuries.
Page 15
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.