hit counter script
Siemens SIMATIC NET Operating Instructions Manual

Siemens SIMATIC NET Operating Instructions Manual

Network components, extender for scalance xm-400
Hide thumbs Also See for SIMATIC NET:

Advertisement

Extender for SCALANCE XM-400
SIMATIC NET
Network components
Extender for SCALANCE XM-400
Operating Instructions
05/2014
C79000-G8976-C332-03
___________________
Introduction
___________________
Safety notices
___________________
Description of the device
___________________
Installation
___________________
Connecting up
___________________
Technical specifications
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET

  • Page 1 ___________________ Extender for SCALANCE XM-400 Introduction ___________________ Safety notices ___________________ Description of the device SIMATIC NET ___________________ Installation Network components ___________________ Extender for SCALANCE XM-400 Connecting up ___________________ Technical specifications Operating Instructions ___________________ Dimension drawings ___________________ Approvals 05/2014 C79000-G8976-C332-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ..............................5 Safety notices ............................9 Description of the device ......................... 11 Product group..........................11 Product overview ......................... 12 Views ............................14 3.3.1 Device view of a PE408 ....................... 14 3.3.2 Device view of a PE408PoE ......................15 3.3.3 Device view of a PE400-8SFP .....................
  • Page 4 Table of contents Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 5: Introduction

    Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting extenders within the SCALANCE XM-400 product group. The configuration and the integration of the device in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: ●...
  • Page 6 In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components", you will find information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network.
  • Page 7 Go to the required product group and make the following settings: tab "Entry list", Entry type "Manuals" You will find the documentation for the SIMATIC NET products relevant here on the data medium that ships with some products: ● Product CD / product DVD ●...
  • Page 8 Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 9: Safety Notices

    Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING...
  • Page 10 Safety notices Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 11: Description Of The Device

    Description of the device Product group SCALANCE XM-400 product group The product group SCALANCE XM-400 consists of basic devices (compact switches) and extenders (port extenders). SCALANCE XM-400 basic device Basic properties The SCALANCE XM-400 basic devices are modular compact switches with fixed RJ-45 ports (10/100/1000 Mbps) and SFP transceiver slots that can be equipped individually.
  • Page 12: Product Overview

    Description of the device 3.2 Product overview Port extender (PE400) Port extenders are modular network components with RJ-45 ports (10/100/1000 Mbps) or SFP transceiver slots. To the left they have an expansion interface to connect to the basic device or to another port extender and to the right they have an expansion interface for additional port extenders.
  • Page 13 Description of the device 3.2 Product overview Components of the product The following components are supplied with every extender: ● One device ● Operating Instructions (compact) ● Securing screw for mounting on an S7 standard rail The following components are also supplied with a PE408PoE: ●...
  • Page 14: Views

    Description of the device 3.3 Views Views 3.3.1 Device view of a PE408 The following figure shows an overview of the components of the PE408. ① Electrical ports ② Centering pin ③ Multipole connector for connection to the expansion interface ④...
  • Page 15: Device View Of A Pe408Poe

    Description of the device 3.3 Views 3.3.2 Device view of a PE408PoE The following figure shows an overview of the components of the PE408PoE. ① Electrical ports ② Centering pin ③ Connectors for the PoE power supplies: L1+/M1 for PoE supply of ports P1 to P4 •...
  • Page 16: Device View Of A Pe400-8Sfp

    Description of the device 3.3 Views 3.3.3 Device view of a PE400-8SFP The following figure shows an overview of the components of the PE400-8SFP. ① Slots for SFP transceivers ② Centering pin ③ Multipole connector for connection to the expansion interface ④...
  • Page 17: Led Display

    Description of the device 3.4 LED display LED display The following figure shows the arrangement of the LEDs. LEDs for displaying the device position L1/L2 LEDs for displaying the PoE power supply (PE408PoE only) LEDs for displaying the port status 3.4.1 LEDs "2"...
  • Page 18: Leds "L1" And "L2

    Description of the device 3.4 LED display 3.4.2 LEDs "L1" and "L2" Note Only the port extender PE408PoE has the LEDs "L1" and L2". The LEDs "L1" and "L2" display information about the PoE power supply at the connectors L1+/M1 und L2+/M2. From the "L1"...
  • Page 19 Description of the device 3.4 LED display Meaning in display mode B In display mode B, the port LEDs indicate the transmission speed. LED color LED status Meaning Port operating at 10 Mbps Green Port operating at 100 Mbps Orange Port operating at 1000 Mbps If there is a connection problem and the type of transmission is fixed (autonegotiation off), the desired status, in other words the set transmission speed (1000 Mbps, 100 Mbps, 10...
  • Page 20: Power Over Ethernet (Poe)

    Description of the device 3.5 Power over Ethernet (PoE) Power over Ethernet (PoE) Function The "Power over Ethernet" function supplies connected devices with power via the Ethernet cable. Devices supplied with power via an Ethernet cable do not require a separate voltage source.
  • Page 21 ● on the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support. (http://support.automation.siemens.com/WW/view/en/79730528/130000) Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 22 Description of the device 3.5 Power over Ethernet (PoE) Power supply and pin assignment The voltage is transferred on the data wires 1, 2, 3 and 6 of the Ethernet cable. With the RJ-45 plug, the pin pairs 1/2 are used for the negative and 3/6 for the positive power supply.
  • Page 23: Installation

    Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
  • Page 24: Types Of Installation

    Installation 4.2 Types of installation WARNING If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 60 ℃, only use cables with admitted maximum operating temperature of at least 80 ℃.
  • Page 25: Installation On A Din Rail

    Installation 4.3 Installation on a DIN rail Installation on a DIN rail Installation WARNING Danger of injury by falling objects The 35 mm DIN rail does not provide adequate support in shipping or when there is severe vibration (> 10 g). When used under these conditions, the device can detach itself and may cause injury to persons.
  • Page 26 Installation 4.3 Installation on a DIN rail Removal To remove the device from a DIN rail, follow the steps below: 1. If the extender is connected to a basic device, disconnect the extender, see section "Fitting an extender (Page 29)". 2.
  • Page 27: Installation On A Standard S7-300 Rail

    Installation 4.4 Installation on a standard S7-300 rail Installation on a standard S7-300 rail Installing on an S7-300 standard rail To install the device on an S7-300 standard rail, follow the steps below: Figure 4-2 S7-300 standard rail mounting ① 1.
  • Page 28: Installation On A Standard S7-1500 Rail

    Installation 4.5 Installation on a standard S7-1500 rail Installation on a standard S7-1500 rail Installing on an S7-1500 standard rail Figure 4-3 S7-1500 standard rail mounting To install the device on an S7-1500 standard rail, follow the steps below: ① 1.
  • Page 29: Fitting An Extender

    Installation 4.6 Fitting an extender Fitting an extender Position The following figure shows the elements required to connect two devices. ① Locking mechanism (on the rear of the device) ② Centering pin ③ Multipole connector for connection to the expansion interface ④...
  • Page 30 Installation 4.6 Fitting an extender Fitting and removing an extender Fitting an extender To fit an extender, follow the steps below: 1. Remove the cover of the expansion interface on the basic device. 2. Fit the two devices together so that the two centering pins are accommodated by the ①...
  • Page 31 Installation 4.6 Fitting an extender Exchanging extenders - with change of medium Exchanging extenders If you replace an electrical extender with an optical extender (or vice versa), this can lead to malfunctions. The IE switch therefore reacts as follows: ● The extender is disabled. ●...
  • Page 32 Installation 4.6 Fitting an extender Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 33: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals.
  • Page 34: Poe Power Supply Of The Pe408Poe

    Connecting up 5.2 PoE power supply of the PE408PoE Safety notices when using the device according to ATEX If you use the device under ATEX conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
  • Page 35 Connecting up 5.2 PoE power supply of the PE408PoE Position and assignment Figure 5-1 Position of the PoE power supply on the PE408PoE and the assignment of the terminal blocks Contact Assignment L1+ 54 VDC Ground L2+ 54 VDC Ground Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 36 Connecting up 5.2 PoE power supply of the PE408PoE Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 37: Technical Specifications

    Technical specifications PE408 The following technical specifications apply to the port extender PE408. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Transmission speed 10 / 100 / 1000 Mbps Electrical data (supply from basic device) Current consumption at 24 V DC 200 mA Effective power loss...
  • Page 38: Pe408Poe

    Technical specifications 6.2 PE408PoE PE408PoE The following technical specifications apply to the port extender PE408PoE: Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Transmission speed 10 / 100 / 1000 Mbps Electrical data (supply from basic device) Current consumption at 24 V DC 200 mA...
  • Page 39: Pe400-8Sfp

    ● on the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● on the Internet pages of Siemens Industry Online Support under the following entry ID: 67701566 (http://support.automation.siemens.com/WW/view/en/67701566) Extender for SCALANCE XM-400...
  • Page 40 Technical specifications 6.3 PE400-8SFP Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 41: Dimension Drawings

    Dimension drawings Note Dimensions are specified in mm. Front view Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 42 Dimension drawings Side view Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 43 Dimension drawings From above Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 44 Dimension drawings Extender for SCALANCE XM-400 Operating Instructions, 05/2014, C79000-G8976-C332-03...
  • Page 45: Approvals

    EN 61000-6-2 : 2005 WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system.
  • Page 46 Safety of electrical equipment In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive: ●...
  • Page 47 ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area".
  • Page 48 Approvals cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2 No. 60950-1-03 Report no. E115352 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc.
  • Page 49: Index

    9 Use in hazardous areas, 9, 23, 33 when connecting up, 33 Basic device, 11 SFP transceiver slots, 11 SIMATIC NET glossary, 7 SIMATIC NET manual, 7 System manual, 6, 46 Centering pin, 14, 29 Components of the product, 13...