RUGGEDCOM RUGGEDCOM RS940G
Installation Guide
1
Figure 12: LC Port
1. Tx Connector
2. Rx Connector
For specifications on the available fiber optic Ethernet ports, refer to
Specifications".
Section 3.3
SFP Optic Ethernet Ports
SFP (Small Form-Factor Pluggable) optic Ethernet ports are available with LC (Lucent Connector) connectors.
Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to
establish a proper link.
Figure 14: LC Port
1. Tx Connector
2. Rx Connector
NOTE
SFP modules, as well as their optical ports, can be safely inserted and removed while the chassis is
powered and operating.
The following sections describe how to install and remove SFP optical ports:
•
Section 3.3.1, "Installing an SFP Optical Port"
•
Section 3.3.2, "Removing an SFP Optical Port"
Section 3.3.1
Installing an SFP Optical Port
To install an SFP optical port, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with
RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability
have not been properly assessed.
SFP Optic Ethernet Ports
2
Figure 13: SC Port
1. Tx Connector
1
1
2. Rx Connector
Section 4.4, "Fiber Optic Ethernet Port
2
Chapter 3
Communication Ports
2
17