ABB Magne 3 Series User Instructions
ABB Magne 3 Series User Instructions

ABB Magne 3 Series User Instructions

Electromagnetic process lock
Hide thumbs Also See for Magne 3 Series:

Advertisement

Quick Links

User instructions
Magne 3 and 4
Electromagnetic process lock
ABB Jokab Safety Varlabergsvägen 11, 434 39
www.abb.com/jokabsafety

Advertisement

Table of Contents
loading

Summary of Contents for ABB Magne 3 Series

  • Page 1 User instructions Magne 3 and 4 Electromagnetic process lock ABB Jokab Safety Varlabergsvägen 11, 434 39 www.abb.com/jokabsafety...
  • Page 2 This can concern tests performed by ABB JOKAB SAFETY and the user must observe the requirements for the application intended. For actual performance, please see the wording in ABB JOKAB SAFETY's Guarantee and Limitation of Liability.
  • Page 3: Table Of Contents

    Operation ............................18 LED indication ................................. 18 Overview of models........................19 Accessories and spare parts (not included) ......................19 Technical data ..........................21 Dimensions ................................24 EU Conformity ..........................26 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 4: Introduction

    This document is intended for authorized installation personnel. Prior knowledge It is assumed that the reader of this document has knowledge of the following:  Basic knowledge of products from ABB Jokab Safety.  General knowledge about safety devices and process locks. ...
  • Page 5: Overview

    Failure to comply with these instructions or standards, and in particular in the case of manipulation and/or modification of the product, invalidates all liability. 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 6: Connections

    3 Connections Important! Shielded cable ought to be used to connect this unit. Caution All cable colors are in accordance with ABB Jokab Safety standard cabling. Magne 3X M12 5 pole male M12 5 pole female connector seen from connector seen from the cable side.
  • Page 7: Magne 4X Dyn

    Important! Shielded cable is necessary between the unit and the rest of the safety loop. Important! Several Magne 4X DYN can be locked with a M12-3S, but then no information will be sent back. 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 8: Magne 4 Dyn-Info

    The safe dynamic or OSSD signals from the interlocking device Eden is used to control the safety application. Important! Shielded cable is necessary between the unit and the rest of the safety loop. 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 9: Magne 4 Ossd-Info

    The safe dynamic or OSSD signals from the interlocking device Eden is used to control the safety application. Important! Shielded cable is necessary between the unit and the rest of the safety loop. Important! Several Magne OSSD-info can be locked with the aid of M12-3G. 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 10: Connecting

    OSSD1 In and OSSD2 In. Otherwise, OSSD output signals will not be generated from Magne. See images below with examples of series connection of Magne 4 DYN-Info and Magne 4 OSSD-Info. Series connection of Magne 4 DYN-Info 2TLC010021T0005 Magne 4 Dyn-Info Pluto 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 11 2TLC010021T0004 Magne 4X Dyn Pluto M12-3S 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 12: Series Connection Of Magne 4 Ossd-Info

    Series connection of Magne 4 OSSD-Info 2TLC010021T0003 Magne 4 OSSD Pluto 2TLC010021T0002 Magne 4 OSSD Sentry 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 13 2TLC010021T0001 Magne 4 OSSD Sentry M12-3G 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 14: Installation And Maintenance

    Please carefully follow the instructions below to avoid personal injuries or damage to the unit.  Caution After installation, check that the surfaces of the magnet and anchor plate are flush and parallel such that full contact is obtained with the door is closed. 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 15: Maintenance

    (EN ISO 13849-1:2015/EN 62061:2005/A2:2015) Contact your nearest ABB Jokab Safety service center or retailer in the event of a malfunction or product damage. Do not attempt to repair the product as this can result in permanent damage, which impairs the safety of the unit, which in turn, can lead to serious personal injuries.
  • Page 16: Replacing Eva

    6) Disconnect power voltage to Magne (marked +24 VDC). 7) Check that the new Eva is within sensory range and connect the power voltage to Magne. The LED in Magne should show green and the programming is completed. 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 17: Troubleshooting

    Check anchor position. centered. Overcurrent on attempted Unit needs replacing. Blue (rapid blinking) locking. Contact ABB Jokab Safety. This section concerns Magne 4 X-DYN, Magne 4 DYN-Info LED indication Supposed cause of fault Check and rectify Eva away from Adam.
  • Page 18: Operation

    Blue (rapid blinking) Overcurrent signaled on attempted locking. LED on Magne Blue (slow blinking) Lock signal but Magne not detecting the anchor plate. (Magne 3 and 4) Blue Magne is locked. 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 19: Overview Of Models

    M12-3A Y connector for connecting several units in series. For Magne Accessories 2TLA020055R0000 3X. Individual status not possible. Cascade locking. M12-3S Y connector for connecting several units in series. For Accessories 2TLA020055R0600 Magne 3X and Magne 4X Dyn. Cascade locking. 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 20 All installation kits include bolts for fitting on ABB Jokab Safety Quick-Guard® fencing systems. A product from Jokab Safety with product code starting with 2TLJ is fully compatible with ABB products with product codes starting with 2TLA. Magne 4 incl. Eva sensor and JSM D21B, JSM D24 plus JSM D27 (closing door) Magne 4 incl.
  • Page 21: Technical Data

    Information output: Max 20 mA Important! Cable dimensioning should be checked when connecting several units in series. Standard cables from ABB/Jokab Safety have a cross sectional area of 0.34 mm . Magne does not cause any power surge when locking is activated.
  • Page 22 Casing: Polycarbonate plastic and anodized aluminum Injected: PUR, epoxy Color Silver Connector M12 5-pole male connector (Magne 3X, 4X DYN) M12 8-pole male connector (Magne 4 DYN-Info OSSD-Info) Mechanical useful life > 10 switches 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 23 The safety-related values are based on interlocking device Eden and do not include the Warning locking function. Important! For further details about the integrated interlocking device, please see user instructions for Eden, available at www.abb.com/jokabsafety. 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 24: Dimensions

    Dimensions Important! All dimensions given in millimeters. Dimensions for Magne 3 and Magne 4 Dimensions for cellular rubber 10 (2x) 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 25 Dimensions for anchor plate 32A without permanent magnet Dimensions for anchor plate 32B with permanent magnet 2TLC172315M0201, rev. K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...
  • Page 26: Eu Conformity

    9 EU Conformity 2TLC172315M0201, rev K www.abb.com/jokabsafety Monday, May 07, 2018 10:51:13 AM...

This manual is also suitable for:

Magne 4 series