Installation Instructions
Model FCM2041-U3
Operator Interface
INTRODUCTION
ALARM
SUPERVISORY
POWER
AUDIBLES
ON
SILENCED
PARTIAL
SYSTEM
DISABLED
CPU FAIL
Figure 1
FCM2041-U3 User Interface
PRE-INSTALLATION
A6V11231630_en--_b
The Model FCM2041-U3 from Siemens Industry, Inc., is the user interface for the
Cerberus PRO Modular system. From the FCM2041-U3 the operator can acknowledge
events, control the system notification appliance circuits and reset the system. De-
tailed information about the nature and location of events can also be displayed.
The FCM2041-U3 is used as the primary user interface in CAB1, CAB2
or CAB3 enclosures. The FCM2041-U3 can also be used as a primary
user interface in a remote REMBOX2 or REMBOX4 enclosure.
TROUBLE
The FCM2041-U3 contains the site specific program as developed in
Zeus. All system logic and supervision is provided by the controller in
the FCM2041-U3.
MENU
The FCM2041-U3 contains a full VGA LCD, Touch Screen and LEDs for
More
Info
+
displaying system status. An audible sounds when there are unac-
ESC
knowledged events on the FCM2041-U3. The display is surrounded by
?
keys that are used to control the displayed information and to navigate
through these screens. Keys are also provided to obtain help and to
enter into the menu features of the FCM2041-U3. (Refer to Figure 1.)
On the back of the FCM2041-U3 there are additional diagnostic displays
to aid in system troubleshooting. This is also where the FCM2041-U3
address is set and where the connection is made to Zeus for program-
ming. (Refer to Figure 2.)
For systems configured to provide Smoke Control (UUKL), refer to the Cerberus PRO
Modular Manual, Document ID A6V11231627 .
Additional labels are available for applications that require French (Canadian), Spanish,
or Portuguese (Brazilian) languages. These labels need to be ordered separately.
Refer to the table below for ordering information.
To apply labels, remove the backing from the labels and apply them to the FCM2041-
U3. (Refer to Figure 3.)
For systems configured for Security, an LED must be configured (on an LCM-8) to
indicate Security. This LED must be present on each node in the system. Refer to the
Cerberus PRO Modular Manual, Document ID A6V11231627, and the Zeus Quick-Start
Manual, P/N 315-033875, for LCM-8 installation and configuration.
Siemens
Siemens
Siemens Industry
Industry
Industry, , , , , Inc.
Siemens
Siemens
Industry
Building
Building
Building
Building
Building T T T T T ec
ec
ec
echnologies Di
ec
hnologies Division
hnologies Di
hnologies Di
hnologies Di
Industry
Inc.
Inc.
Inc.
Inc.
vision
vision
vision
vision