table of contents table of co ntent s The Device ............................3 Function Overview ........................3 Adding the Keypad ..........................4 Configuring the Keypad ........................6 LED Settings ..........................7 Technical Data ............................. 8 Technical Data........................... 8 Resetting the Device..........................9 │2 Product Manual 2CQA 100 007 B0001 │...
The Keypad allows the user to select from up to four different scenes/environments and operate special functions in an ABB-free@home™ Smart Home system. It has 4 exchangeable keys. The device does not directly control a load but instead commands other free@home components to turn ON or OFF based on the configured settings.
Adding the Keypad Adding the Keypad This section describes how to add the Keypad to the system. STEP 1: Install the Light Switch Install the device by following the Operating Instructions included in the original packaging. Note: After installation, the Keypad will not function. To configure the Keypad, it will need to be added to the free@home network.
Page 5
Adding the Keypad Start Go to Settings > free@home radio > Search for wireless devices The SysAP will now search for the Keypad. Note: The Keypad can only be found if the search starts within 30 minutes after the Keypad was connected to power.
Configuring the Keypad Configuring the Keypad STEP 1: Enter Keypad Settings Click on the Keypad symbol to show its settings. Select which button to configure first. Define a name for this Keypad. STEP 2: Configure Button A) In the settings menu, press “Top push button” (or the name that corresponds to the button currently being configured).
Configuring the Keypad C) If desired, add additional devices to be switched from the same button by repeating steps A and B. In the picture below, the user created a custom scene that turns off all lights on the ground floor and added this to the “Top push button”.
Technical Data Technical Data Technical Data Designation Value Operating Voltage 120 VAC, 60 Hz Operating-Voltage Range 110 VAC to 125 VAC Connection Neutral Wire Required Maximum Power Consumption < 1 W Standby* Power Consumption < 300 mW Transmission Protocol free@home, 2.400 - 2.483 GHz, meshed Transmission Power <...
Resetting the Device Resetting the Device Reset the Light Switch if it was previously assigned to a different System Access Point (SysAP). The reset will remove any previous connection and enable the device to connect to a new SysAP. Reset procedure: A) Press and hold the bottom key for at least 20 seconds.
Page 10
860 Ridge Lake Boulevard changes to the contents of this Memphis, TN 38120 document without prior notice. abb.com/freeathome The detailed specifications agreed upon apply for orders. ABB accepts no responsibility for possible errors Customer Service: or incompleteness in this 800-816-7809 document.