Table 7-32
LED
Blinking green
Green
Firepower 7115, 7125, and AMP7150 Physical and Environmental Parameters
The following table describes the physical attributes and the environmental parameters for the appliance.
Table 7-33
Firepower 7115, 7125, and AMP7150 Physical and Environmental Parameters
Parameter
Form factor
Dimensions (D x W x H)
Weight
maximum installed
Copper 1000BASE-T
Copper 1000BASE-T SFP
Fiber 1000BASE-SX SFP
Fiber 1000BASE-LX SFP
Power supply
Operating temperature
Non-operating temperature
Operating humidity
Non-operating humidity
Altitude
Cooling requirements
Firepower 7000 and 8000 Series Installation Guide
7-20
Firepower 7115, 7125, and AMP7150 Power Supply LED (continued)
Description
AC input is present; volts on standby, the power supply is switched off.
The power supply is plugged in and on.
Description
1U
21.6 in. x 19.0 in. x 1.73 in. (54.9 cm x 48.3 cm x 4.4 cm)
29.0 lbs (13.2 kg)
Gigabit copper Ethernet bypass-capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Gigabit copper Ethernet non-bypass capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Fiber non-bypass capable interfaces with LC connectors
Cable and distance: SX is multimode fiber (850 nm) at 550 m (standard)
656 ft (200 m) for 62.5 µm/125 µm fiber
1640 ft (500 m) for 50 µm/125 µm fiber
Fiber non-bypass capable interfaces with LC connectors
Cable and distance: LX is single mode fiber (1310 nm) at 10 km for
9 µm/125 µm fiber (standard)
450 W dual redundant (1+1) AC power supplies
Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC maximum)
Current: 3A maximum for 90 VAC to 132 VAC, per supply
1.5A maximum for 187 VAC to 264 VAC, per supply
Frequency range: 47 Hz to 63 Hz
o
o
o
o
41
F to 104
F (5
C to 40
C)
o
o
o
-29
F to 158
F (-20
C to 70
5% to 85% non-condensing
5% to 90%, non-condensing with a maximum wet bulb of 82
o
o
o
o
77
F to 95
F (25
C to 35
C)
Store the unit below 95% non-condensing relative humidity. Acclimate below maximum
operating humidity at least 48 hours before placing the unit in service.
0ft (sea level) to 5905 ft (0 m to 1800 m)
900 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.