Honeywell
IQ Force™
Gas Detector
Honeywell Analytics
800-663-4164 403-248-9226
Fax 403-575-3708
03JUN2012
P/N 50105843-047
Version 01
http://www.honeywell.com

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell IQ Force

  • Page 1 Safe Operation Manual Honeywell IQ Force™ Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com...
  • Page 2 HONEYWELL IQ Force PERSONAL PORTABLE GAS DETECTORS HAVE BEEN DESIGNED FOR THE DETECTION AND MEASUREMENT OF POTENTIALLY HAZARDOUS ATMOSPHERIC CONDITIONS IN ORDER TO ASSURE THAT THE USER IS PROPERLY WARNED OF POTENTIALLY DANGEROUS ATMOSPHERIC CONDITIONS, IT IS ES- SENTIAL THAT THE INSTRUCTIONS IN THIS MANUAL BE READ, FULLY UNDERSTOOD, AND FOLLOWED.
  • Page 3: Table Of Contents

    Table of Contents ERTIFICATION NFORMATION IGNAL ORDS PERATING EMPERATURE ARNINGS AND AUTIONS 1. D ESCRIPTION Methods of sampling Optional sample-draw pump 1.2.1 Special precautions when using the motorized pump Manual sample-draw kit 1.3.1 Manual sample-draw kit usage 2. C ALIBRATION 3.
  • Page 4: Certification Information

    Operating Temperature The Honeywell IQ Force’s operating temperature range is printed on the label on the back of the instrument. Use of the IQ Force outside of its specified op- erating temperature range may result in inaccurate and potentially dangerous readings.
  • Page 5 Customers are strongly urged to use only Honeywell calibration materials when cali- brating the IQ Force. Honeywell offers calibration kits and long-lasting cylinders of test gas specifically developed for easy IQ Force calibration. Use of non-standard ca- libration gas and/or calibration kit components can lead to dangerously inaccurate readings and may void the standard Sperian Instrumentation warranty.
  • Page 6: Description

    Description immediately surrounds the detector. The IQ Force can also be used to sample re- mote locations with the hand-aspirated sam- ple-draw kit or with a motorized continuous sample-draw pump (both available separate- ly). During remote sampling, the gas sample is drawn into the sensor compartment through the probe assembly and a length of tubing.
  • Page 7: Optional Sample-Draw Pump

    A motorized sample-draw pump is available taining a concentration of solvent or fuel for the IQ Force for situations requiring conti- that may be greater than 10% LEL. nuous “hands free” remote monitoring. Manual sample-draw kit...
  • Page 8: Calibration

    Li-Ion batteries Calibration The IQ Force is powered by a Li-Ion rechar- geable battery. See the User Manual for spe- The accuracy of the IQ Force should be veri- cific instructions concerning the storage and fied on a regular basis.
  • Page 9: Appendix A: Calibration Frequency Recommendation

    There is only one sure way to verify note: 13-366 “Use of ‘equivalent’ that a sensor can respond to the gas The IQ Force is shipped with a calibration gas mixtures.” This for which it is designed. That is to...
  • Page 10: Appendix B: Toxic Sensor Cross-Sensitivity

    Appendix B: Toxic Sensor Cross-Sensitivity The table below provides the cross-sensitivity response of the IQ Force toxic gas sensors to common interference gases. The values are expressed as a percentage of the primary sensitivity, or the reading of the sensor when ex- posed to 100ppm of the interfering gas at 20ºC.