Siemens SIMATIC NET SCALANCE S615 Configuration Manual page 144

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Configuring with Web Based Management
4.7 "Layer 3" menu
● "Source IP Subnet" input box
Enter the subnet of the sender.
The subnet can also be a single PC or another subset of the subnet. Use the CIDR
notation.
● "Translated Source IP Subnet" input box
Enter the subnet with which the subnet of the sender will be replaced. Can only be edited
in the "SourceNAT" settings.
The subnet can also be a single PC or another subset of the subnet. Use the CIDR
notation.
● "Destination IP Subnet" input box
Enter the subnet of the recipient.
The subnet can also be a single PC or another subset of the subnet. Use the CIDR
notation.
● "Translated Destination IP Subnet" input box
Enter the subnet with which the subnet of the recipient will be replaced. Can only be
edited in the "DestinationNAT" settings.
The subnet can also be a single PC or another subset of the subnet. Use the CIDR
notation.
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Type
Shows the direction of the address translation.
● Source Interface
Shows the source interface.
● Destination Interface
Shows the destination interface.
● Source IP Subnet
Shows the subnet of the sender.
● Translated Source IP Subnet
Shows the subnet of the sender with which the subnet of the sender is replaced.
● Destination IP Subnet
Shows the subnet of the recipient.
● Translated Destination IP Subnet
Shows the subnet of the recipient with which the subnet of the recipient is replaced.
144
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02