hit counter script
Download Print this page
Panasonic VL-MW250BX Installation Manual
Panasonic VL-MW250BX Installation Manual

Panasonic VL-MW250BX Installation Manual

Wireless video intercom system
Hide thumbs Also See for VL-MW250BX:

Advertisement

Installation Guide

Model
Wireless Video
Main Monitor
Name
Intercom System
VL-SW250BX VL-MW250BX
Model No.
VL-V566BX
VL-MW250BX
VL-V566BX is described as "Door
station" and VL-MW250BX is described
For door station and main monitor station
as "Main monitor station" in this guide.
LPlease read this Installation Guide before installing the unit and save for future reference.
LPlease read this Installation Guide carefully, and install the unit safely and correctly by
following the instructions. Panasonic assumes no responsibility for injuries or property
damage resulting from failures arising out of improper installation or operation inconsistent
with both the Installation Guide and Operating Instructions.
LPlease confi rm the wiring schematic diagram in this Installation Guide when you increase
an optional equipment
.
Included accessories for installation
For the door station
For the main monitor station
LWood screws ..................2
LMounting bracket ............1
(3.8 mm × 20 mm)
LWood screws ..................2
(4 mm × 16 mm)
L Attached to the bag the door station
L Attached to the rear of the main
is in.
monitor station.
For your safety
To prevent severe injury and loss of life/property, read this section carefully before using the
unit to ensure proper and safe operation of your unit.
WARNING
LTo reduce the risk of electric shock, do not disassemble this unit. Refer servicing to an
authorized service center when service is required. Opening or removing covers may
expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric
shock when the unit is subsequently used.
LDo not make any wiring connections when the power supply is turned on.
LNever install wiring during a lightning storm.
LDo not overload power outlets and extension cords. This can result in the risk of fi re or
electric shock.
LDo not install the main monitor station in the following places:
– Places where the main monitor station may be splashed with water or chemicals.
– Places where there is a high concentration of dust, or high humidity.
LWhen existing chime wires are used, it is possible that they contain AC voltage. Electric
shock or unit damage could result. Contact an authorized service center.
CAUTION
LThe power cord is used as the main disconnect device. Ensure that the power outlet is
installed near the product and is easily accessible.
LInstall the unit securely adhering to the instructions in this guide to prevent it from falling off
the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC (autoclaved
lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.
Do not install the unit using a different method from the instructions in this guide.
LIf the wiring is outdoors, use a protection tube or a surge protector.
LIf the wiring is underground, do not make any connections underground.
LIf the wiring is underground, use a protection tube.
1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan
© Panasonic System Networks Co., Ltd. 2010
PNQW2395ZA SV0910SN0
SW250BX_Installation_Guide_面付.indd 1
SW250BX_Installation_Guide_面付.indd 1
Before installation
To avoid malfunction or communication disturbances, do not install either the door station or the
main monitor station in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places where echoing is frequent.
– Places near a high concentration of dust, hydrogen sulfi de, ammonia, sulfur, or noxious fumes.
– Within 2 m of a TV, microwave, personal computer, air conditioner or any other electrical device.
Installation position of the door station and camera range
N
Views when the camera is facing forwards at 0° (default).
LExample: Installation height is 1450 mm (standard position).
Side view
Top view
1810 mm
Center of
the door
station
66°
650 mm
Image range:
960 mm
Image
range
1450 mm
87°
1160 mm
500 mm
500 mm
The camera angle can be adjusted using the camera angle control lever on the rear of the door
station (step 3, "Installing the door station"), so that the image range can be changed.
N
Side view when the camera is installed
N
Top view when the camera is facing
lower than the standard position, and
left or right at 15° *
1
.
facing upwards at 15°.
LExample: Installation height is 1100 mm.
LExample: Camera angle faces left 15°.
1690 mm
Image range:
Center of
1080 mm
710 mm
the door
66°
station
270 mm
810 mm
Image
range
87°
1100 mm
980 mm
500 mm
500 mm
*
1
If the camera points 15° upwards, the left or right angle is less than 7°.
Note:
LThe measurements and angles are for reference purposes and may vary depending on the
environment.
LIf a strong light is shining on the door station, the visitor's face may not be distinguishable.
Do not place the door station in the following locations.
– Where most of the background is the sky.
– Where the background is a white wall, and direct sunlight will refl ect off it.
– Where direct sunlight will shine on the door station.
LDo not place the door station in the locations where echoing occurs, causing the unit to beep
frequently.
L Make sure the rear of the door station is not subject to water.
Standard installation position of the main monitor station
Place the main monitor station in a location that your eyes are the same height as the center of the
display.
If a position of installation for the main monitor station is specifi ed
Install the mounting bracket to one of the following positions.
Position of installation for the main monitor station
Note:
LThis unit is using an electric wave frequency of 2.4 GHz. Read "For best performance" in the
Operating Instructions.
LIn areas surrounded by a high electrical fi eld, disturbances may occur in the main monitor
station's image or sound.
LBe sure to install the main monitor station more than 5 m away from the door station.
LDo not place any objects within 20 cm of the main monitor station. This may cause
communication errors or malfunction.
LDo not install the main monitor station inside a wall.
LDo not install the main monitor station in places where it will be affected by extremely high-
frequency radio waves (near broadcasting antennas etc.). This may cause the display to fl icker
or an interrupting noise to occur.
If you change to the main monitor station from chime, bell or buzzer
Existing wires (e.g. chime, bell or buzzer) may connect to power supplies (AC 100 – 240 V or 24 V).
If you connect the main monitor station through such existing wires, electric shock or unit damage
may occur. Contact the dealer where you purchased.

Installing the door station

Important:
LOn the bottom surface of the door station, there are holes to allow water to drain.
Do not cover them up when installing.
1
Remove the mounting base.
A Open the screw
B Loosen the
cover.
mounting screw.
TScrewdriver
Water drain
Mounting base
holes
2
Attach the mounting base to the wall securely using the wood screws (3.8 mm x 20 mm).
LInstall the mounting base on a vertical fl at wall.
LBefore drilling, refer to "Before installation" for installation location.
Wood screws
Mounting base
83.5 mm
Wall
Wire (Not included)
3
Adjust the camera angle using the camera angle control lever.
Rear view
Camera angle
control lever
Left
Right
(maximum 15°)
(maximum 15°)
Upwards
(maximum 15°)
<Examples of camera angle>
<Facing forwards>
<Facing upwards>
<Facing right>
<Facing upper right>
LThe angle can also be adjusted to the left
or upper left.
Important:
LWhen the camera angle is adjusted to the upper left or upper right, the image may be slightly
distorted.
4
Connect the wire, then mount the door station to the mounting base.
A Unscrew the screws.
B Mount the door station to
Push in the wire to the terminal connectors
the mounting base.
(non polar), then tightly fasten the screws.
C Fasten the screw, then
close the screw cover.
Wire (connecting to the main monitor station)

Installing the main monitor station

1
Attach the mounting bracket to the wall securely using the wood screws (4 mm x 16 mm).
LInstall the mounting bracket on a vertical fl at wall.
LBefore drilling, refer to "Before installation" for installation location.
Wood screws
83.5 mm
Wall
Wire (Not included)
Mounting bracket
2
Attach the wires connected to the door station to the terminal connector.
LConnect the wire correctly according to "Wiring schematic diagram".
LWhile pressing on the button with a pointed object such as a screwdriver, insert the wire into
the terminal connector. (To disconnect a wire, press on the button while pulling out.)
Button
Terminal
connector
Stripped end of
the wire
Wire from the door station
9 mm
3
Mount the main monitor station to the mounting bracket.
A Fit into position as shown in the fi gure.
B Push the main monitor station down until it is secure.
A
B
4
Connect the plug into an AC outlet (100 – 240 V AC).
Important:
LConnect the plug to the power outlet which is easily accessible.
To use an existing wire in your home
1 Be sure to turn off the power and confi rm that the wire type is CAT-3 (ø0.5) or 22 AWG
(ø0.65). If the wire type is not CAT-3 (ø0.5) or 22 AWG (ø0.65), change the wire to either of the
specifi ed wire types.
2 Install the main monitor station and the door station.
3 Turn on the power.
Wiring schematic diagram
Set up correctly according to the following wiring schematic diagrams and "Wire type and
distance".
Optional equipment
(Refer to pages 42-43 in the Operating Instructions.)
Door station 1 *
1
Door station 2
(Non polar)
(Non polar)
You can also connect
an optional lobby
station for apartment
PBX*
3
complexes.*
2
Main monitor station
Terminal box
(4-conductor wiring)
Door (Door Opener) 1 *
4
(Non polar)
(Non polar)
(Non polar)
Door (Door Opener) 2 *
4
Power plug
(100 – 240 V AC)
*
1
For VL-MW250BX users: The door station is optional (not included).
*
2
Connecting an optional lobby station for apartment complexes
Be sure to perform the following to ensure proper operation:
LConnect to terminal D1/D2 on the main monitor station.
LAfter connecting to the main monitor station, change the setting of "LOBBY
CONNECTION" to "YES" using the main monitor station. (Refer to page 38 in the
Operating Instructions.)
*
3
For information about compatible PBXs, refer to page 4 in the Operating Instructions.
*
4
Connecting a door opener
LBefore connecting to a door opener, make sure that:
– S1/S2/S3/S4 terminal: Normally open/Actively short
– The door opener is less than 30 V AC (1 A), 24 V DC (1 A).
– S1/S2/S3/S4 terminal on the main monitor station is not the power supply to the door
opener. If the door opener needs a power supply device to connect to the main monitor
station, contact the dealer where you purchased the door opener.
L The door opener for the door station connected to terminal D1/D2 must be
connected to terminal S1/S2. The other door opener for the door station connected
to terminal D3/D4 must be connected to terminal S3/S4.
L You can connect up to 2 door openers to the main monitor station. If the main monitor
station is connected to a PBX, one of the 2 door openers can be connected to the PBX
and operated from the PBX extensions.
Note:
LWhen you move the main monitor station, make sure the PBX is disconnected.
LThe door opener wiring schematic diagram is only an example. Refer to the wiring
instructions provided with your door opener and PBX for details.
Wire type and distance
LWire (between the main monitor station and the door station):
Type
Distance
Loop resistance
General cable CAT-3
Maximum 50 m
10 Ω or lower
General cable 22 AWG (ø 0.65) Maximum 100 m
LWire (between the main monitor station and PBX):
Type: General cable CAT-3 or 22 AWG (ø 0.65)
Distance: Maximum 100 m
2010/08/25 13:00:49
2010/08/25 13:00:49

Advertisement

loading

This manual is also suitable for:

Vl-sw250bx