Mitsubishi Industrial Robot
Encoder Distribution Unit Manual
CR750/CR751 series controller
CRn‐700 series controller
BFP‐A3300
Configuration example 2
Encoder
: 1 unit (Line driver output encoder only)
Robot controller
: 8 units
Encoder distribution unit : 1 unit
Encoder 1 distribution
Encoder distribution unit
24V
DC24
(Power supply)
Encoder 1
ENC1OUT1
ENC1IN
ENC1OUT2
Encoder 1 cascade
ENC1OUT3
ENC1CSC
ENC1OUT4
ENC2OUT1
ENC2IN
ENC2OUT2
ENC2OUT3
Connection  between 
ENC2CSC
ENC2OUT4
ENC1CSC and ENC2IN 
is needed
Encoder 2 distribution
*Please do not wire the unused terminal blocks.
Precautions
Do not use the unit in excess of rated voltage or it could suffer damage. 
Wire the power supply correctly or it could suffer damage.
Wire the cable in the shortest path in order to avoid noise.
Do not short or  ground  the output signal, or it can be burst or damaged.
Make sure the unit is turned off when wiring, inserting or pulling out of the connector, or 
it could suffer damage.
Do not drop this unit.
Place this unit on an even surface, free from vibration.
■Introduction
Encoder distribution unit 2F‐YZ581 is used when one rotary encoder is connected to multiple robot controllers when 
the tracking function is used. The details of 2F‐YZ581 are described in this sheet. For details of the tracking function, 
please refer to the "Tracking function manual" attached to the robot .
■Configuration diagram
The connection method differs according to the number of encoders and robot controllers. Connect instruments by 
referring to the following examples of configurations. Please have power supply and encoders ready.
Configuration example 1
Encoder distribution unit
Encoder
: 1 unit
24V
Robot controller
: 4 units
DC24
(Power supply)
Encoder distribution unit : 1 unit
Encoder 1
ENC1IN
Encoder 1 cascade
ENC1CSC
ENC2IN
*Please do not wire the unused terminal blocks.
ENC2CSC
Configuration example 3
Connection between Encoder distribution units is needed to 
Encoder
: 2 units
connect the encoder to more than five robot controllers. Refer to 
Robot controller
: 4 units
the wiring diagram and the enclosed area below   
Encoder distribution unit : 1 unit
Encoder distribution unit
Robot controller
24V
DC24
(Power supply)
Encoder 1
Robot controller
ENC1IN
Encoder 1 cascade
Robot controller
ENC1CSC
Encoder  2
Robot controller
ENC2IN
Encoder 2 cascade
Robot controller
ENC2CSC
Robot controller
Encoder distribution unit
Robot controller
24V
DC24
(Power supply)
Robot controller
ENC1IN
ENC1CSC
ENC2IN
Connection between 
Encoder distribution units 
is needed.
ENC2CSC
*Please do not wire the unused terminal blocks.
■Specifications
Model name
Supported robot
Encoder input
Supported encoder
Cable
Output
channels
Output type
Power
supply
Encoder 1 distribution
Protection specification
Robot controller
Ambient environment
Robot controller
Ambient air temperature
ENC1OUT1
ENC1OUT2
Ambient humidity
ENC1OUT3
Robot controller
Mass
ENC1OUT4
■Wiring diagram
The short‐connector  has to be inserted into the correct  
Robot controller
ENC2OUT1
point  to change encoder type. Please insert the short‐
ENC2OUT2
connector according to encoder type in reference to the 
ENC2OUT3
following figures. Please refer to "Tracking Function Manual" 
ENC2OUT4
Encoder  distribution
for the details about  wiring directions for the robot controller.
Encoder type: Line driver output (MODE1)
.
Encoder1 /Encoder2
Encoder 1 distribution
Robot controller
ENC1OUT1
ENC1OUT2
Robot controller
ENC1OUT3
ENC1OUT4
Robot controller
ENC2OUT1
ENC2OUT2
ENC2OUT3
Robot controller
ENC2OUT4
Encoder type: Open collector output / Voltage output (MODE2)
Encoder  2 distribution
Connection for cascade
Encoder 1 distribution
Encoder1 / Encoder2
Robot controller
ENC1OUT1
Voltage output
ENC1OUT2
Open collector output
Robot controller
ENC1OUT3
ENC1OUT4
Robot controller
ENC2OUT1
ENC2OUT2
ENC2OUT3
Robot controller
ENC2OUT4
Encoder  2 distribution
Item
Specification
2F‐YZ581
RH‐SDH series / RV‐SD series, RH‐SQH series / RV‐SQ series
RH‐F‐D series / RV‐F‐D series, RH‐F‐Q series / RV‐F‐Q series
2 channel
Output type: Open collector output/Voltage output
/Line driver output
Resolution(pulse/rotation) : max 2000
(non‐compliant 4000 , 8000)
Operation checked encoder: E6B2‐CWZ1X‐2000 (omron)
Type:Shielded twisted‐pair cable
Conductor size::Refer to Wiring directions
Cable length:Refer to Communication specifications
For robot controller
4 channels (in the case two encoders are connected)
8 channels (in the case one encoder is connected)
For cascading
1 channel
Line driver output
Input voltage
24Vdc(±10%)
Power consumption
500mA
Encoder supply
Voltage: 5Vdc, Current: 160mA, 2 channel
IP20
General environment
0℃~40℃
45~85%
Approx. 600 g
No.
1
Line driver output
2
Open collector output
Voltage output
Encoder distribution unit
A
A
A
A
A
A
B
B
B
B
B
B
Z
Z
Z
Z
Z
Z
GND
0V
0V
Line driver output
GND
0V
0V
0V
SLD
ENC1IN /
ENC1OUT1‐ENC1OUT4 /
5
V
5
V
ENC2IN
ENC2OUT1‐ENC2OUT4
0V
Power supply
A
+
+24V
DC24
A
B
B
MODE1
Z
Z
Short‐connector
0V
MODE2
ENC1CSC / ENC2CSC
0V
Encoder distribution unit
A
A
A
A
A
B
B
B
B
B
Z
Z
Z
Z
Z
GND
0V
0V
0V
0V
GND
SLD
0V
ENC1IN /
ENC1OUT1‐ENC1OUT4 /
5
V
5
V
ENC2IN
ENC2OUT1‐ENC2OUT4
0V
A
Power supply
+
24V
A
DC24
B
B
MODE1
Z
Z
0V
MODE2
ENC1CSC / ENC2CSC
0V
Short‐connector
Remarks
CR750/CR751 series controller
CRn‐700 series controller
Only 1 channel available
Supported encoder could be changed
with the shorting connector. Refer to
wiring diagram for detail.
Enable to increase
the number of
output channel by cascade.
Depends on the encoder type.
Without inflammable gas or corrosive
gas
Without dew drops
Encoder type
Short‐connector point
MODE1
MODE2
A
A
B
B
Robot controller
Z
Z
GND
GND
A
A
B
Encoder distribution unit
B
Z
ENC1IN/ENC2IN
Z
GND
GND
A
A
B
B
Robot controller
Z
Z
GND
GND
A
A
B
Encoder distribution unit
B
Z
ENC1IN/ENC2IN
Z
GND
GND
BFP‐A3300

Advertisement

loading

Summary of Contents for Mitsubishi Electric CR750 Series

  • Page 1 ■Specifications Precautions Item Specification Remarks Do not use the unit in excess of rated voltage or it could suffer damage.  Model name 2F‐YZ581 Wire the power supply correctly or it could suffer damage. Supported robot RH‐SDH series / RV‐SD series, RH‐SQH series / RV‐SQ series CR750/CR751 series controller Mitsubishi Industrial Robot RH‐F‐D series / RV‐F‐D series, RH‐F‐Q series / RV‐F‐Q series CRn‐700 series controller Wire the cable in the shortest path in order to avoid noise. Encoder input 2 channel Only 1 channel available...
  • Page 2 ■Outline drawings ■Measures against noise / static electricity * 1 U n i t f i x i n g * 2 A t t a c h i n g D i n r a i l a d a p t e r * 3 E a r t h c o n n e c t i o n * 4 A t t a c h i n g c o v e r a g a i n s t s t a t i c e l e c t r i c i t y Connect to ground to avoid problems due to noise and static electricity using *3 screw holes. Bolts and cables are not included.