1

SPECIFICATIONS

Type
NPN output type
Item
Model No. (Note 1)
Adjustable range (Note 2)
Sensing range
with white non-glossy paper
at setting distance 2m
Hysteresis
Supply voltage
Current consumption
50mA or less
NPN open-collector transistor
・Maximum sink current: 100mA
・Applied voltage: 30V DC or less
(between output and 0V)
・Residual voltage: 1V or less
Output
(at 100mA sink current)
Output operation
Short-circuit protection
Response time
Operation indicator
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition) (Note 4)
Distance adjuster
Automatic interference
prevention function
Protection
Ambient temperature
Ambient humidity
Emitting element
Receiving element
Material
Cable
Weight
Accessory
Notes: 1) The model No. with suffix '-J' stands for the connector type. (EQ-34W is excluded.)
(e.g.) As for the connector type of EQ-34: 'EQ-34-J'
Use the mating cables as shown below.
CN-24-C2 (Straight type, 4-core, 2m)
CN-24-C5 (Straight type, 4-core, 5m)
The model No. with suffix '-C5' stands for the 5m cable length type. (EQ-34-PN is excluded.)
(e.g.) As for the 5m cable length type of EQ-34 'EQ-34-C5'
2)
The adjustable range stands for the maximum sensing range which can
be set with the adjuster. The sensor can detect an object 0.1m, or more,
away. However, the detectable area of the Near (Sub) type of the
EQ-34W begins at 0.2m.
3) The Near (Sub) distance adjustable range, L
EQ-34W Near (Sub) distance adjustable range
2
1.5
Near (Sub) distance
adjustable range
1
L
(m)
2
0.5
0
0.5 1 1.5 2
Far (Main) setting distance L
4)
Refer to '
5
STABILITY INDICATOR' for the details of the stability indicator.
5)
Detection may become unstable depending on the setting conditions or the sensing objects. After setting up this product, make
sure to check operations using actual sensing objects.
2
INTENDED PRODUCTS FOR
CE MARKING
The models listed under '
1
SPECIFICATIONS'
come with CE Marking.
As for all other models, please contact our office.
Thank you very much for purchasing Panasonic
products. Please read this Instruction Manual
carefully and thoroughly for the correct and
optimum use of this product. Kindly keep this
manual in a convenient place for quick reference.
WARNING
Adjustable range reflective
PNP output type
EQ-34
EQ-34-PN
0.2 to 2m
0.1 to 2m
10% or less of operation distance (With white non-glossy paper)
10 to 30V DC Ripple P-P 10% or less
55mA or less
PNP open-collector transistor
・Maximum source current: 100mA
・Applied voltage: 30V DC or less
(between output and +V)
・Residual voltage: 1V or less
(at 100mA source current)
0.4V or less
(at 16mA sink current)
(at 16mA source current)
Switchable either Detection-ON or Detection-OFF
Incorporated
2ms or less
Red LED (lights up when the output is ON)
2-turn mechanical adjuster with pointer
Incorporated (Note 5)
IP67 (IEC)
-20 to +55℃ (No dew condensation or icing allowed), Storage: -25 to +70℃
35 to 85% RH, Storage: 35 to 85% RH
Infrared LED (modulated)
2-segment photodiode
Enclosure: Polyalylate and Polyethylene terephthalate, Lens: Polyalylate
2
0.3mm
3-core cabtyre cable, 2m long
Approx. 150g
Adjusting screwdriver: 1pc.
CN-24L-C2 (Elbow type, 4-core, 2m)
CN-24L-C5 (Elbow type, 4-core, 5m)
, changes with the setting of the Far (Main) distance, L
2
Far (Main) setting distance L
2m
1.5m
1m
0.5m
0.2m
(m)
1
Two outputs type
EQ-34W
Far (Main): 0.2 to 2m
Near (Sub): Refer to diagram in (Note 3)
Far (Main): 0.1 to 2m
Near (Sub): 0.2 to 2m
[with Near (Sub) distance for adjuster at max.]
90mA or less
<Far (Main) output, Near (Sub) output>
NPN open-collector transistor
・Maximum sink current: 100mA
・Applied voltage: 30V DC or less
(between output and 0V)
・Residual voltage: 1V or less
0.4V or less
(at 100mA sink current)
0.4V or less
(at 16mA sink current)
Far (Main) output: Red LED
[lights up when the Far (Main) output is ON]
Near (Sub) output: Red LED
[lights up when the Near (Sub) output is ON]
Far (Main): 2-turn mechanical ad-
juster with pointer
Near (Sub): Variable adjuster
2
0.3mm
4-core cabtyre cable, 2m long
Non-detectable range
Actual sensing
0.1m
range of the sensor
0.2m
Adjustable range
, as shown in the table below.
1
EQ-34W
Near (Sub) distance
1
adjustable range L
2
1 to 2m
0.85 to 1.5m
0.65 to 1m
0.35 to 0.5m
0.2m
3
CAUTIONS
This product has been developed / produced for
industrial use only.
Make sure that the power supply is OFF while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within
the rating.
If power is supplied from a commercial switch-
ing regulator, ensure that the frame ground
(F.G.) terminal of the power supply is connect-
ed to an actual ground.
In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicini-
ty of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage
lines or power lines or put them in the same race-
way. This can cause malfunction due to induction.
Extension up to total 100m, is possible with
2
0.3mm
, or more, cable. However, in order to re-
duce noise, make the wiring as short as possible.
Do not use during the initial transient time
(50ms) after the power supply is switched on.
Take care that the sensor is not directly exposed
to fluorescent lamp from a rapid-starter lamp, a
high frequency lighting device or sunlight etc., as
it may affect the sensing performance.
Avoid dust, dirt, and steam. Do not use it in pla-
ces having excessive vapor, dust, etc., or where
it may come in direct contact with corrosive gas.
Take care that the sensor does not come in con-
tact with water, oil, grease, organic solvents, such
as, thinner etc., strong acid or alkaline.
This sensor is suitable for indoor use only.
Make sure that stress by forcible bend or pulling
is not applied directly to the sensor cable joint.
Since the cable end is not waterproof, do not
use the sensor in the application where water
may seep in from the cable end.
When connecting the mating cable to the con-
nector type sensor, the tightening torque should
be 0.4N・m or less.
4
MOUNTING
● The tightening torque should be 0.8N・m or
less.
M4 nut
● Care must be taken regarding the sensor
mounting direction with respect to the object's
direction of movement.
2m
Good
Sensing
object
Sensing object
When detecting a specular object (aluminum or
copper foil, etc.) or an object having a glossy
surface or coating, please take care that there
are cases when the object may not be detected
due to a small change in angle, wrinkles on the
object surface, etc.
When a specular body is present below the
sensor, use the sensor by tiling it slightly up-
wards to avoid wrong operation.
Not good
Specular face
M4 (length 25mm)
screw with washers
Sensor
mounting
bracket
MS-EQ3-2
(Optional)
Good
Not good
Sensing object
Sensing object
Do not make the sen-
sor detect an object
in this direction be-
cause it may cause
unstable operation.
Good
Specular face
Tilt

Advertisement

loading

Summary of Contents for Panasonic EQ-34

  • Page 1: Specifications

    CN-24L-C5 (Elbow type, 4-core, 5m) ● Care must be taken regarding the sensor The model No. with suffix '-C5' stands for the 5m cable length type. (EQ-34-PN is excluded.) mounting direction with respect to the object's (e.g.) As for the 5m cable length type of EQ-34 'EQ-34-C5' direction of movement.
  • Page 2 Far (Main) setting is the position NEAR MAIN center point between EQ-34, EQ-34-PN and the Far (Main) side / Near Internal circuit Users' circuit (Sub) side of EQ-34W is for use when a sensing ・ Near (Sub) side Symbols...D...

This manual is also suitable for:

Eq-34-pnEq-34w